AUX Air Con Error Codes

Aux Air Conditioner Troubleshooting
November 3, 2018 at 9:18 pm


If the following phenomena are found, the problem is not from the 
air-conditioner itself.

Problems
The motor is heard operating but the air-conditioner dose not work when the indoor unit is powered on

Causes
Since the air-conditioner is powered on, it will come to working condition as long as you press the ON/OFF button of the remote control and the Signal is well received.

Problems
The compressor stops running but the indoor fan motor keeps working when it is at cooling mode with the indoor temperature higher than set temperature.

Causes
If you turn off the air-conditioner and restart it immediately, it will return to normal in 3 minutes, after that, the air-conditioner will automatically adjust the indoor fan speed to what you set.

Problems
The compressor works discontinuously at dehumidifying mode.

Causes
The air-conditioner will automatically control the working of the compressor according to the inside temperature

Problems
The air-conditioner does not work while the LED display is on.

Causes
The TIMER is set with the air-conditioner; it will be in hold on condition. If the TIMER setting is cancelled, the air conditioner will return to normal working condition

Problems
The compressor works discontinuously at cooling and dehumidifying mode, and the indoor fan motor slows down.

Causes
The compressor stops internally or the fan motor slows down to prevent the indoor heat exchanger from being frozen.

Error Codes;

Aux Air Conditioner Error Codes
Aux Air Conditioner Error Codes

1.HS(Y) HSA(Y) HSB(Y) HSF (Y) HV(Y) HVA(Y) digital display for the series air-conditioner faults:

Error CodesProblem
E1Plastic temp sensor is abnormal. The display precedence level: 2
E2Copper temp sensor is abnormal (outdoor). The display precedence level: 4
E3Copper temp sensor is abnormal (indoor). The display precedence level: 3
E4PG motor feedback is abnormal. The display precedence level: 1
E5Abnormality of outdoor unit
E6Over-current oprotection
E7External feedback failure
E8Overheat protection
E9Water pump failure
dFIndicates "dF"or defrosting indicator displays
L1Failure of coiled pipe sensor
L2Failure of room temperature sensor
L6Without feedback of internal fan motor
Wiring Diagram
Wiring Diagram

2. H (Except KFR-25G/H) H1 HA HB series faults display:

  • Fault source: PG motor feedback is abnormal
  • Display mode: Timing light twinkles 4 times in every 8 seconds
  • The display precedence level: 1

 

  • Fault source: Plastic temp sensor is abnormal
  • Display mode: Timing light twinkles 1 times in every 8 seconds
  • The display precedence level: 2

 

  • Fault source: Copper temp sensor is abnormal (indoor)
  • Display mode: Timing light twinkles 2 times in every 8 seconds
  • The display precedence level: 3

 

  • Fault source: Copper temp sensor is abnormal (indoor)
  • Display mode: Timing light twinkles 1 times in every 1 seconds
  • The display precedence level: 4

3. H(Y) Model air conditioner fault display:

  • Fault source: PG motor feedback is abnormal
  • Display mode: Timing light twinkles 4 times in every 8 seconds
  • The display precedence level: 1

 

  • Fault source: Plastic temp sensor is abnormal
  • Display mode: Timing light twinkles 1 times in every 8 seconds
  • The display precedence level: 2

 

  • Fault source: Copper temp sensor is abnormal (indoor)
  • Display mode: Timing light twinkles 2 times in every 8 seconds
  • The display precedence level: 3

 

  • Fault source: Copper temp sensor is abnormal (outdoor)
  • Display mode: Timing light twinkles 1 times in every 1 seconds
  • The display precedence level: 4

4. EA EC EM EY EZ EAA EAD EL HS1 HSZ HL1 HLZ P P1 ZZ CZ digital display series ac faults:

  • Fault source: PG motor feedback is abnormal
  • Display mode: E4
  • The display precedence level: 1

 

  • Fault source: Plastic temp sensor is abnormal
  • Display mode: E1
  • The display precedence level: 2

 

  • Fault source: Copper temp sensor is abnormal (indoor)
  • Display mode: E3
  • The display precedence level: 3
Aux Air Conditioner Remote Control
Aux Air Conditioner Remote Control

5. All of the other E series except EA EC EM EY EZ EAA EAD:

  • Fault source: PG motor feedback is abnormal
  • Display mode: Timing light twinkles 4 times in every 8 seconds
  • The display precedence level: 1

 

  • Fault source: Plastic temp sensor is abnormal
  • Display mode: Timing light twinkles 1 times in every 8 seconds
  • The display precedence level: 2

 

  • Fault source: Copper temp sensor is abnormal (indoor)
  • Display mode: Timing light twinkles 2 times in every 8 seconds
  • The display precedence level: 3

6. QA QB QD digital display series ac faults:

  • Fault source: PG motor feedback is abnormal
  • Display mode: E4
  • The display precedence level: 1

 

  • Fault source: Plastic temp sensor is abnormal
  • Display mode: E1
  • The display precedence level: 2

 

  • Fault source: Copper temp sensor is abnormal
  • Display mode: E3
  • The display precedence level: 3

 

  • Fault source: Over-current oprotection
  • Display mode: E6
  • The display precedence level: 4

7. QC QQ light display series air-conditioner faults:

  • Fault source: PG motor feedback is abnormal
  • Display mode: Timing light twinkles 4 times in every 8 seconds
  • The display precedence level: 1

 

  • Fault source: Plastic temp sensor is abnormal
  • Display mode: Timing light twinkles 1 times in every 8 seconds
  • The display precedence level: 2

 

  • Fault source: Copper temp sensor is abnormal
  • Display mode: Timing light twinkles 3 times in every 8 seconds
  • The display precedence level: 3

 

  • Fault source: Over-current oprotection
  • Display mode: Timing light twinkles 6 times in every 8 seconds
  • The display precedence level: 4

8. Faults display of 18000BTU~24000BTU wall unit series ac non-digital tube displays:

  • Fault source: PG motor feedback is abnormal
  • Display mode: Timing light twinkles 1 times in every 8 seconds
  • The display precedence level: 2
  • appearance: System turns off

 

  • Fault source: Plastic temp sensor is abnormal
  • Display mode: Timing light twinkles 2 times in every 8 seconds
  • The display precedence level: 3
  • appearance: System turns off

 

  • Fault source: Copper temp sensor is abnormal
  • Display mode: Timing light twinkles 8 times in every 8 seconds
  • The display precedence level: 4
  • appearance: System doesn’t turns off

Digital tube displays:

  • Fault source: PG motor feedback is abnormal
  • Display mode: E1
  • The display precedence level: 2
  • appearance: System turns off

 

  • Fault source: Plastic temp sensor is abnormal
  • Display mode: E3
  • The display precedence level: 3
  • appearance: System turns off

 

  • Fault source: Copper temp sensor is abnormal
  • Display mode: E2
  • The display precedence level: 4
  • appearance: System doesn’t turn off

 

  • E1: Temperature sensor of air intake fault
  • E2: Temperature sensor of outdoor coil fault
  • E3: Temperature sensor of indoor coil fault
  • E4: PG motor of indoor unit feedback fault

AUX Air Conditioning Wall Mounted Error Codes

AUX Air Conditioning Wall Mounted Error Codes
AUX Air Conditioning Wall Mounted Error Codes

Self-check information: Hint to defrosting

  • Self-check code of luminotron: Flicker 1 time/1s
  • Digital self-check code: Indicates “dF“or defrosting indicator displays

Self-check information: Hint to defense against cold wind

  • Self-check code of luminotron: Flicker 1 time/3s
  • Digital self-check code: Fan motor picture not running

Self-check information: Failure of room temperature sensor

  • Self-check code of luminotron: Flicker 2 times/4s (Flicker 2 times/8s)
  • Digital self-check code: E2/(L2)

Self-check information: Failure of coiled pipe sensor

  • Self-check code of luminotron: Flicker 3 times/5s (Flicker 1 time/8s)
  • Digital self-check code: E3/(L1)

Self-check information: Abnormality of outdoor unit

  • Self-check code of luminotron: Flicker 4 times/6s (luminating)
  • Digital self-check code: E4/(E5)

Self-check information: Without feedback of internal fan motor

  • Self-check code of luminotron: Flicker 5 times/7s (Flicker 6 times/8s)
  • Digital self-check code: E5/(L6)

Self-check information: Zero crossing signal without current

  • Self-check code of luminotron: Flicker 6 times/8s
  • Digital self-check code: E6

Self-check information: External feedback failure

  • Self-check code of luminotron: Flicker 7 times/9s
  • Digital self-check code: E7

Self-check information: Overheat protection

  • Self-check code of luminotron: Flicker 8 times/10s
  • Digital self-check code: E8

Self-check information: Water pump failure

  • Self-check code of luminotron: Flicker 9 times/11s
  • Digital self-check code: E9

Comments

The bigger the house the cooling problems becomes greater if not controlled with the HVAC technician. Heating and Cooling Unionville The article is really on the point.
Unknown said…
Whats E5 in aux air conditioner??
Unknown said…
AUX Non invader Errar-CL

Popular posts from this blog

Hisense VRF Air Conditioner Error Codes

 Inverter-driven Multi-split Air Conditioner (Heat Pump) Error Codes Problem 01 Activation of Protection Device (Float Switch). Activation of Float Switch. 02 Activation of Protection Device (High Pressure Cut). Activation of PSH. 03 Abnormality between Indoor and Outdoor. Incorrect Wiring, Loose Terminals, Disconnect Wire, Blowout of Fuse, Outdoor Unit Power OFF. 04 Abnormality between Inverter PCB and Outdoor PCB. Inverter PCB - Outdoor PCB Transmission Failure. 04. Abnormality between Fan Controller and Outdoor PCB. Fan Controller - Outdoor PCB Transmission Failure. 05 Abnormality Power Source Phases. Incorrect Power Source, Connection to Reversed Phase, Open-Phase. 06 Abnormal Inverter Voltage. Outdoor Voltage Drop, Insufficient Power Capacity. 06. Abnormal Fan Controller Voltage. Outdoor Voltage Drop, Insufficient Power Capacity. 07 Decrease in Discharge Gas Superheat. Excessive Refrigerant Charge, Failure of Thermistor, Incorrect Wiring, Incorrect Piping Connection, Expansion Val

Rittal Air Conditioner Error Codes

  System messages are shown on the display screen of the Comfort controller via the displays A1 to A20 and E0. Rittal Air Conditioner Error Codes Error Codes System message Possible cause A1 Enclosure door open Door open or door limit switch incorrectly positioned A2 Internal temperature of enclosure too high Cooling capacity inadequate/unit undersized. Error as a consequence of messages A03 to A17. A3 Filter monitoring Filter mat soiled A4 Ambient temperature too high/too low Ambient temperature outside of admissible operating range (+10°C to +60°C) A5 Icing hazard Operational display in case of icing hazard. A6 PSAH pressure-operated switch Ambient temperature too high A7 Evaporator coil Lack of coolant; sensor in front of or behind condenser defective. A8 Condensate warning Condensate discharge kinked or blocked A9 Condenser fan blocked or defective Blocked or defective A10 Evaporator fan blocked or defective Blocked or defective A11 Compressor Compressor overloaded A12 Condenser Op