Skip to main content

Aux AC Error Codes and Troubleshooting

 AUX Air Conditioning Error Codes;

Aux Air Conditioner Error Codes
Aux Air Conditioner Error Codes

1.HS(Y) HSA(Y) HSB(Y) HSF (Y) HV(Y) HVA(Y) digital display for the series air-conditioner faults:

Error CodesProblem
E1Plastic temp sensor is abnormal. The display precedence level: 2
E2Copper temp sensor is abnormal (outdoor). The display precedence level: 4
E3Copper temp sensor is abnormal (indoor). The display precedence level: 3
E4PG motor feedback is abnormal. The display precedence level: 1
E5Abnormality of outdoor unit
E6Over-current oprotection
E7External feedback failure
E8Overheat protection
E9Water pump failure
dFIndicates "dF"or defrosting indicator displays
L1Failure of coiled pipe sensor
L2Failure of room temperature sensor
L6Without feedback of internal fan motor
Wiring Diagram
Wiring Diagram

2. H (Except KFR-25G/H) H1 HA HB series faults display:

  • Fault source: PG motor feedback is abnormal
  • Display mode: Timing light twinkles 4 times in every 8 seconds
  • The display precedence level: 1

 

  • Fault source: Plastic temp sensor is abnormal
  • Display mode: Timing light twinkles 1 times in every 8 seconds
  • The display precedence level: 2

 

  • Fault source: Copper temp sensor is abnormal (indoor)
  • Display mode: Timing light twinkles 2 times in every 8 seconds
  • The display precedence level: 3

 

  • Fault source: Copper temp sensor is abnormal (indoor)
  • Display mode: Timing light twinkles 1 times in every 1 seconds
  • The display precedence level: 4

3. H(Y) Model air conditioner fault display:

  • Fault source: PG motor feedback is abnormal
  • Display mode: Timing light twinkles 4 times in every 8 seconds
  • The display precedence level: 1

 

  • Fault source: Plastic temp sensor is abnormal
  • Display mode: Timing light twinkles 1 times in every 8 seconds
  • The display precedence level: 2

 

  • Fault source: Copper temp sensor is abnormal (indoor)
  • Display mode: Timing light twinkles 2 times in every 8 seconds
  • The display precedence level: 3

 

  • Fault source: Copper temp sensor is abnormal (outdoor)
  • Display mode: Timing light twinkles 1 times in every 1 seconds
  • The display precedence level: 4

4. EA EC EM EY EZ EAA EAD EL HS1 HSZ HL1 HLZ P P1 ZZ CZ digital display series ac faults:

  • Fault source: PG motor feedback is abnormal
  • Display mode: E4
  • The display precedence level: 1

 

  • Fault source: Plastic temp sensor is abnormal
  • Display mode: E1
  • The display precedence level: 2

 

  • Fault source: Copper temp sensor is abnormal (indoor)
  • Display mode: E3
  • The display precedence level: 3
Aux Air Conditioner Remote Control
Aux Air Conditioner Remote Control

5. All of the other E series except EA EC EM EY EZ EAA EAD:

  • Fault source: PG motor feedback is abnormal
  • Display mode: Timing light twinkles 4 times in every 8 seconds
  • The display precedence level: 1

 

  • Fault source: Plastic temp sensor is abnormal
  • Display mode: Timing light twinkles 1 times in every 8 seconds
  • The display precedence level: 2

 

  • Fault source: Copper temp sensor is abnormal (indoor)
  • Display mode: Timing light twinkles 2 times in every 8 seconds
  • The display precedence level: 3

6. QA QB QD digital display series ac faults:

  • Fault source: PG motor feedback is abnormal
  • Display mode: E4
  • The display precedence level: 1

 

  • Fault source: Plastic temp sensor is abnormal
  • Display mode: E1
  • The display precedence level: 2

 

  • Fault source: Copper temp sensor is abnormal
  • Display mode: E3
  • The display precedence level: 3

 

  • Fault source: Over-current oprotection
  • Display mode: E6
  • The display precedence level: 4

7. QC QQ light display series air-conditioner faults:

  • Fault source: PG motor feedback is abnormal
  • Display mode: Timing light twinkles 4 times in every 8 seconds
  • The display precedence level: 1

 

  • Fault source: Plastic temp sensor is abnormal
  • Display mode: Timing light twinkles 1 times in every 8 seconds
  • The display precedence level: 2

 

  • Fault source: Copper temp sensor is abnormal
  • Display mode: Timing light twinkles 3 times in every 8 seconds
  • The display precedence level: 3

 

  • Fault source: Over-current oprotection
  • Display mode: Timing light twinkles 6 times in every 8 seconds
  • The display precedence level: 4

8. Faults display of 18000BTU~24000BTU wall unit series ac non-digital tube displays:

  • Fault source: PG motor feedback is abnormal
  • Display mode: Timing light twinkles 1 times in every 8 seconds
  • The display precedence level: 2
  • appearance: System turns off

 

  • Fault source: Plastic temp sensor is abnormal
  • Display mode: Timing light twinkles 2 times in every 8 seconds
  • The display precedence level: 3
  • appearance: System turns off

 

  • Fault source: Copper temp sensor is abnormal
  • Display mode: Timing light twinkles 8 times in every 8 seconds
  • The display precedence level: 4
  • appearance: System doesn’t turns off

Digital tube displays:

  • Fault source: PG motor feedback is abnormal
  • Display mode: E1
  • The display precedence level: 2
  • appearance: System turns off

 

  • Fault source: Plastic temp sensor is abnormal
  • Display mode: E3
  • The display precedence level: 3
  • appearance: System turns off

 

  • Fault source: Copper temp sensor is abnormal
  • Display mode: E2
  • The display precedence level: 4
  • appearance: System doesn’t turn off

 

  • E1: Temperature sensor of air intake fault
  • E2: Temperature sensor of outdoor coil fault
  • E3: Temperature sensor of indoor coil fault
  • E4: PG motor of indoor unit feedback fault

AUX Air Conditioning Wall Mounted Error Codes

AUX Air Conditioning Wall Mounted Error Codes
AUX Air Conditioning Wall Mounted Error Codes

Self-check information: Hint to defrosting

  • Self-check code of luminotron: Flicker 1 time/1s
  • Digital self-check code: Indicates “dF“or defrosting indicator displays

Self-check information: Hint to defense against cold wind

  • Self-check code of luminotron: Flicker 1 time/3s
  • Digital self-check code: Fan motor picture not running

Self-check information: Failure of room temperature sensor

  • Self-check code of luminotron: Flicker 2 times/4s (Flicker 2 times/8s)
  • Digital self-check code: E2/(L2)

Self-check information: Failure of coiled pipe sensor

  • Self-check code of luminotron: Flicker 3 times/5s (Flicker 1 time/8s)
  • Digital self-check code: E3/(L1)

Self-check information: Abnormality of outdoor unit

  • Self-check code of luminotron: Flicker 4 times/6s (luminating)
  • Digital self-check code: E4/(E5)

Self-check information: Without feedback of internal fan motor

  • Self-check code of luminotron: Flicker 5 times/7s (Flicker 6 times/8s)
  • Digital self-check code: E5/(L6)

Self-check information: Zero crossing signal without current

  • Self-check code of luminotron: Flicker 6 times/8s
  • Digital self-check code: E6

Self-check information: External feedback failure

  • Self-check code of luminotron: Flicker 7 times/9s
  • Digital self-check code: E7

Self-check information: Overheat protection

  • Self-check code of luminotron: Flicker 8 times/10s
  • Digital self-check code: E8

Self-check information: Water pump failure

  • Self-check code of luminotron: Flicker 9 times/11s
  • Digital self-check code: E9

 

Aux AC Error Codes and Troubleshooting
Aux AC Error Codes and Troubleshooting

Troubleshooting Guide

Problem: The motor is heard operating but the air-conditioner dose not work when the indoor unit is powered on

Cause: Since the air-conditioner is powered on, it will come to working condition as long as you press the ON/OFF button of the remote control and the signal is well received.

Problem: The compressor stops running but the indoor fan motor keeps working when it is at cooling mode with the indoor temperature higher than set temperature.

Cause: If you turn off the air-conditioner and restart it immediately, it will return to normal in 3 minutes, after that, the air-conditioner will automatically adjust the indoor fan speed to what you set.

Problem: The compressor works discontinuously at dehumidifying mode.

Cause: The air-conditioner will automatically control the working of the compressor according to the inside temperature

Problem: The air-conditioner dose not work while the LED display is on.

Cause: The TIMER is set with the air-conditioner,it will be in hold on condition. If the TIMER setting is cancelled, the air-conditioner will return to normal working condition.

Problem: The compressor works discontinuously at cooling and dehumidifying mode, and the indoor fan motor slows down.

Cause: The compressor stops internally or the fan motor slows down to prevent the indoor heat exchanger from being frozen.

AUX Air conditioner manual PDF

Split type wall mounted air-conditioner Owners Manual

Comments

Popular posts from this blog

AUX Air Con Error Codes

Aux Air Conditioner Troubleshooting November 3, 2018 at 9:18 pm If the following phenomena are found, the problem is not from the  air-conditioner itself. Problems The motor is heard operating but the air-conditioner dose not work when the indoor unit is powered on Causes Since the air-conditioner is powered on, it will come to working condition as long as you press the ON/OFF button of the remote control and the Signal is well received. Problems The compressor stops running but the indoor fan motor keeps working when it is at cooling mode with the indoor temperature higher than set temperature. Causes If you turn off the air-conditioner and restart it immediately, it will return to normal in 3 minutes, after that, the air-conditioner will automatically adjust the indoor fan speed to what you set. Problems The compressor works discontinuously at dehumidifying mode. Causes The air-conditioner will automatically control the working of the compressor according to the insi

Acson AC Error Codes and Troubleshooting

Acson AC Error Codes and Troubleshooting   The code indication changes as shown below, and notifies with a long beep. Wall Mounted AC Inverter Unit Error Codes Operation / Faulty Indication E1 Room air sensor contact loose / short. Check room sensor connection / change room sensor E2 Indoor coil sensor contact open. Check indoor coil sensor connection / change indoor coil sensor E3 Outdoor coil sensor contact open. Check outdoor coil sensor connection / change outdoor coil sensor E4 Compressor overload protection / Indoor / Outdoor coil sensor short. If running ampere highly increase, change the compressor. If not, replace the coil sensor E5 Gas leak. Check for leakage & repair / Top up refrigerant E6 Pump fault. Clear the clogging at drain pipe. If pump is not working, change the pump E7 Outdoor coil sensor exist (MS model). Remove outdoor coil sensor E8 Hardware error (tact switch pin short). Check for the tact switch pin condition E9 No Feedback from indoor fan. Check indoor fan

Rittal Air Conditioner Error Codes

  System messages are shown on the display screen of the Comfort controller via the displays A1 to A20 and E0. Rittal Air Conditioner Error Codes Error Codes System message Possible cause A1 Enclosure door open Door open or door limit switch incorrectly positioned A2 Internal temperature of enclosure too high Cooling capacity inadequate/unit undersized. Error as a consequence of messages A03 to A17. A3 Filter monitoring Filter mat soiled A4 Ambient temperature too high/too low Ambient temperature outside of admissible operating range (+10°C to +60°C) A5 Icing hazard Operational display in case of icing hazard. A6 PSAH pressure-operated switch Ambient temperature too high A7 Evaporator coil Lack of coolant; sensor in front of or behind condenser defective. A8 Condensate warning Condensate discharge kinked or blocked A9 Condenser fan blocked or defective Blocked or defective A10 Evaporator fan blocked or defective Blocked or defective A11 Compressor Compressor overloaded A12 Condenser Op