Vestel AC Error Codes and Troubleshooting

 Error Messages are displayed, respectively by first the Er icon and then the special code (01, 02, …, 20, etc.) of the failure. In that case, do nothing to the air conditioner and contact with the Authorised Service. Er11 and Er13 are not error messages. If you see these messages, apply the steps under the following protection messages section.

Vestel AC Error Code and Troubleshooting
Vestel AC Error Code and Troubleshooting
Error CodesCause
dFThe icing on the outdoor unit is being defrosted. After the defrosting operation is accomplished, your air conditioner will continue to operate in the heating mode, the product should not be turned off while this mode is enabled.
REMake the arc control for your electrical wiring, if the problem is not fixed call for the service. If the problem comes out very frequently, contact with the authorised service.
SrIn case of certain failures, in order to not to spoil you comfort, your air conditioner continues to operate despite the failure. In that case, you don’t need to turn your air conditioner off. It is needed to contact with the authorized service immediately
HLThere is a fluctuation in the electrical voltage, wait for its recovery.
ER11-ER13The codes of ER-13 and ER-11, and the messages displayed on the indoor unit display, are protection messages in the aim of preventing the product from some harmful consequences resulting from an excessiv current coming from the compressor. The product turns off right after it enters into these protections. In the case that it is re-operated by the remote control, cooling and heating functions restart.

Protection Messages

dF: The icing on the outdoor unit is being defrosted. After the defrosting operation is accomplished, your air conditioner will continue to operate in the heating mode, the product should not be turned off while this mode is enabled.

RE: Make the arc control for your electrical wiring, if the problem is not fixed call for the service. If the problem comes out very frequently, contact with the authorised service.

Sr: In case of certain failures, in order to not to spoil you comfort, your air conditioner continues to operate despite the failure. In that case, you don’t need to turn your air conditioner off. It is needed to contact with the authorized service immediately

HL: There is a fluctuation in the electrical voltage, wait for its recovery.

ER11-ER13: The codes of ER-13 and ER-11, and the messages displayed on the indoor unit display, are protection messages in the aim of preventing the product from some harmful consequences resulting from an excessiv current coming from the compressor. The product turns off right after it enters into these protections. In the case that it is re-operated by the remote control, cooling and heating functions restart.

Vestel AC Remote Control
Vestel AC Remote Control

Troubleshooting

When you notice an abnormal situation in your air conditioner, you may attempt to troubleshoot according to the following instructions. If your air conditioner still do not work properly, contact with the Call Centre or the nearest Authorised Service. You may access the authorised services list and contact information from the web site.

Problem: The air conditioner is not running.

Reason:

  1. Power cut.
  2. On/off button is not turned on.
  3. The fuse is broken.
  4. Batteries of the remote have gone down.
  5. The time set to start running has not been reached.
  6. The remote control is not detecting.
  7. Light source is too close to the air conditioner.

Solution:

  1. Wait for the power to be back.
  2. Turn on the air conditioner.
  3. Have the fuse changed.
  4. Change the batteries.
  5. Wait or cancel the setting.
  6. Change the batteries.
  7. Some light sources that are close to the air conditioner, may prevent its functioning creating a magnetic influence. Retry to use the remote control after disabling the light source. If the problem is solved, it would be useful to change the light source.

Problem: The air conditioner is blowing air, but cooling and heating performance is bad.

Reason:

  1. There is a mistake in temperature setting.
  2. Air filter is clogged with dust.
  3. Air inlet or outlet of the air conditioner is blocked.
  4. Door and windows are open.

Solution:

  1. Set appropriate temperature. See application methods
  2. Clean up dust filters.
  3. Clean the materials that cause blocking.
  4. Close the windows and the doors.

Problem: Air flow does not start immediately during heating.

Reason: The necessary temperature for heating has not been reached.

Solution: If air flow starts before the temperature rises, an undesired cooling effect will occur. In order to prevent this, air flow will start after necessary temperature is reached. This is not due to a malfunction of the air conditioner and it is not a failure.

Problem: The air conditioner is blowing air, but it does not cool.

Reason:

  1. Air inlet or outlet of the air conditioner is blocked.
  2. Compressor protection (3 min).
  3. There is a mistake in temperature setting.

Solution:

  1. Clean the materials that cause blocking and restart the air conditioner.
  2. Wait.
  3. Set appropriate temperature.

Problem: There is clicking sound coming from the air conditioner.

Reason: Temperature change.

Solution: Changes in temperature cause expansion and contraction of plastic materials. This is not due to a malfunction of the air conditioner and it is not a failure.

Vestel Air Conditioner Manual PDF

Comments

Popular posts from this blog

Rittal Air Conditioner Error Codes

  System messages are shown on the display screen of the Comfort controller via the displays A1 to A20 and E0. Rittal Air Conditioner Error Codes Error Codes System message Possible cause A1 Enclosure door open Door open or door limit switch incorrectly positioned A2 Internal temperature of enclosure too high Cooling capacity inadequate/unit undersized. Error as a consequence of messages A03 to A17. A3 Filter monitoring Filter mat soiled A4 Ambient temperature too high/too low Ambient temperature outside of admissible operating range (+10°C to +60°C) A5 Icing hazard Operational display in case of icing hazard. A6 PSAH pressure-operated switch Ambient temperature too high A7 Evaporator coil Lack of coolant; sensor in front of or behind condenser defective. A8 Condensate warning Condensate discharge kinked or blocked A9 Condenser fan blocked or defective Blocked or defective A10 Evaporator fan blocked or defective Blocked or defective A11 Compressor Compressor overloaded A12 Condense...

Samsung DVM-S VRF Error Codes

  DVM Digital Variable Multi VRF Systems Error Codes Samsung DVM VRF Error Codes Error code related indoor unit: Error Codes Explanation E-101 Indoor unit communication error. Indoor unit can not receive any data from outdoor unit. E-102 Communication error between indoor unit and outdoor unit. Displayed in indoor unit. E-108 Error due to repeated address setting (When 2 or more devices has same address within the network) E-121 Error on indoor temperature sensor of indoor unit (Short or Open) E-122 Error on EVA IN sensor of indoor unit (Short or Open) E-123 Error on EVA OUT sensor of indoor unit (Short or Open) E-128 EVA IN temperature sensor of indoor unit is detached from EVA IN pipe E-129 EVA OUT temperature sensor of indoor unit is detached from EVA OUT pipe E-130 Heat exchanger in/out sensors of indoor unit are detached E-135 RPM feedback error of indoor unit's cleaning fan E-149 Error due to AHU master indoor unit sensor setting. E-151 Error due to opened EEV of indoor unit ...

Panasonic VRF AC Error Codes and Troubleshooting

  Indoor unit is detecting error signal from remote controller (and system controller). Panasonic Mini VRF AC Error Codes and Troubleshooting Error Codes Meaning E01 Error in receiving serial communication signal. E02 Error in transmitting serial communication signal. E03 Indoor unit is detecting error signal from remote controller. E04 Error in receiving serial communication signal. When turning on the power supply, the number of connected indoor units does not correspond to the number set. E06 Error of the outdoor unit in receiving serial communication signal from the indoor unit. E08 Indoor unit address setting is duplicated. E09 Remote controller address connector. E12 Starting auto address setting is prohibited. This alarm message shows that the auto address connector CN-A.ADD is shorted while other RC line is executing auto address operation. E15 Error in auto address setting. E16 Error in auto address setting. E20 No indoor unit is connected during auto address setting. E24 ...