Skip to main content

Westinghouse Air Conditioner Error Codes

 Please read all of the instructions before using the air conditioner and keep this manual for future reference. The air conditioner you purchased has R410a gas  refrigerant a environmental friendly gas which does  not damage the ozone layer.

Westinghouse Air Conditioner Error Codes
Westinghouse Air Conditioner Error Codes

Error signals on the display:

In case of error, the display on the indoor unit shown the following error codes:

Error CodesDescription of the trouble
E0Indoor unit EEPROM parameter error.
E1Indoor / outdoor units communication error.
E2Zero-crossing signal detection error.
E3Indoor fan speed has been out of control.
E4Open circuit or short circuit of indoor room temperature T1 sensor.
E5Open circuit or short circuit of evaporator coil temperature T2 sensor
ECRefrigerant Leakage Detection
F1Open circuit or short circuit of outdoor ambient T4 temperature sensor
F2Open circuit or short circuit of condenser coil temperature T3 sensor
F3Open circuit or short circuit of compressor discharge T5 temperature sensor
F4Outdoor unit EEPROM parameter error
P0IPM malfunction or IGBT over-strong current protection
P1Over voltage or over low voltage protection
P2High temperature protection of compressor top diagnosis and solution
P4Inverter compressor drive error
Westinghouse Air Conditioner Error Codes; E1-E2-E6
Westinghouse Air Conditioner Error Codes; E1-E2-E6

Westinghouse Air Conditioner Troubleshooting

Malfunction: The appliance does not operate

Possible causes:

  • Power failure/plug pulled out
  • Damaged indoor/outdoor unit fan motor
  • Faulty compressor thermomagnetic circuit breaker
  • Faulty protective device or fuses.
  • Loose connections or plug pulled out
  • It sometimes stops operating to protect the appliance.
  • Voltage higher or lower than the voltage range
  • Active TIMER-ON function
  • Damaged electronic control board
Westinghouse Air Conditioner Remote Control Display
Westinghouse Air Conditioner Remote Control Display

Malfunction: Strange odour

Possible causes: Dirty air filter

Malfunction: Noise of running water

Possible causes: Back flow of liquid in the refrigerant circulation

Malfunction: A fine mist comes from the air outlet

Possible causes: This occurs when the air in the room becomes very cold, for example in the COOLING or DEHUMIDIFYING/DRY modes.

Malfunction: A strange noise can be heard

Possible causes: This noise is made by the expansion or contraction of the front panel due to variations in temperature and does not indicate a problem.

Westinghouse Air Conditioner Indoor unit display
Westinghouse Air Conditioner Indoor unit display

Malfunction: Insufficient airflow

Possible causes:

  • Unsuitable temperature setting.
  • Obstructed air conditioner intakes and outlets.
  • Dirty air filter.
  • Fan speed set at minimum.
  • Other sources of heat in the room.
  • No refrigerant.

Malfunction: The appliance does not respond to commands

Possible causes:

  • Remote control is not near enough to indoor unit.
  • The batteries of remote control nearly has no power.
  • Obstacles between remote control and signal receiver in indoor unit.

Malfunction: The display is off

Possible causes:

  • Active LIGHT function
  • Power failure

Malfunction: The display is off

Possible causes:

  • Active LIGHT function
  • Power failure

Malfunction: Switch off the air conditioner immediately and cut off the power supply in the event of:

Possible causes:

  • Strange noises during operation.
  • Faulty electronic control board
  • Faulty fuses or switches.
  • Spraying water or objects inside the appliance.
  • Overheated cables or plugs.
  • Very strong smells coming from the appliance.
Westinghouse Air Conditioner Parts
Westinghouse Air Conditioner Parts

SPLIT TYPE ROOM AIR CONDITIONER MANUAL PDF

Comments

Popular posts from this blog

Rittal Air Conditioner Error Codes

  System messages are shown on the display screen of the Comfort controller via the displays A1 to A20 and E0. Rittal Air Conditioner Error Codes Error Codes System message Possible cause A1 Enclosure door open Door open or door limit switch incorrectly positioned A2 Internal temperature of enclosure too high Cooling capacity inadequate/unit undersized. Error as a consequence of messages A03 to A17. A3 Filter monitoring Filter mat soiled A4 Ambient temperature too high/too low Ambient temperature outside of admissible operating range (+10°C to +60°C) A5 Icing hazard Operational display in case of icing hazard. A6 PSAH pressure-operated switch Ambient temperature too high A7 Evaporator coil Lack of coolant; sensor in front of or behind condenser defective. A8 Condensate warning Condensate discharge kinked or blocked A9 Condenser fan blocked or defective Blocked or defective A10 Evaporator fan blocked or defective Blocked or defective A11 Compressor Compressor overloaded A12 Condense...

Panasonic VRF AC Error Codes and Troubleshooting

  Indoor unit is detecting error signal from remote controller (and system controller). Panasonic Mini VRF AC Error Codes and Troubleshooting Error Codes Meaning E01 Error in receiving serial communication signal. E02 Error in transmitting serial communication signal. E03 Indoor unit is detecting error signal from remote controller. E04 Error in receiving serial communication signal. When turning on the power supply, the number of connected indoor units does not correspond to the number set. E06 Error of the outdoor unit in receiving serial communication signal from the indoor unit. E08 Indoor unit address setting is duplicated. E09 Remote controller address connector. E12 Starting auto address setting is prohibited. This alarm message shows that the auto address connector CN-A.ADD is shorted while other RC line is executing auto address operation. E15 Error in auto address setting. E16 Error in auto address setting. E20 No indoor unit is connected during auto address setting. E24 ...

Vestel AC Error Codes and Troubleshooting

  Error Messages   are displayed, respectively by first the   Er   icon and then the special code (01, 02, …, 20, etc.) of the failure. In that case, do nothing to the air conditioner and contact with the Authorised Service.   Er11   and   Er13   are not error messages. If you see these messages, apply the steps under the following protection messages section. Vestel AC Error Code and Troubleshooting Error Codes Cause dF The icing on the outdoor unit is being defrosted. After the defrosting operation is accomplished, your air conditioner will continue to operate in the heating mode, the product should not be turned off while this mode is enabled. RE Make the arc control for your electrical wiring, if the problem is not fixed call for the service. If the problem comes out very frequently, contact with the authorised service. Sr In case of certain failures, in order to not to spoil you comfort, your air conditioner continues to operate despite the f...