Voltas Air Conditioner Error Codes

 Voltas Tata Inverter Split AC Error Codes (Model: 20170325) :

Voltas Air Conditioner Error Codes-min
Voltas Air Conditioner Error Codes-min
Error CodesProblem
EEIndoor machine EE fault
E0Outdoor EE fault
E1Indoor fan fault
E2Indoor fan zero-crossing detection abnormal
E3Indoor coil fault and sensor fault
E4Indoor ambient temperature sensor fault
E5Fan Operation Error
E6Indoor and outdoor machine communication fault
E8Outdoor communication fault
F1Compressor starting abnormal
F2Compressor out of step fault
F3IPM module fault
F4Compressor shell roof fault/protection
F5Discharge temperature sensor fault
F6Section temperature sensor fault
F7Outdoor coil temperature sensor fault
F8Outdoor ambient temperature sensor fault
F9Outdoor DC fan fault
P1Outdoor machine AC current protection
P2Compressor phase current protection
P3Outdoor unit over-high or over-low AC voltage protection
P4DC voltage over-high or over-low voltage protection
P5IPM over-high temperature protection
P6Discharge temperature overheat protection
P7Cooling indoor coil anti freezing protection
P8Cooling outdoor coil overheat protection
P9Heating indoor coil overheat protection
PCCooling outdoor ambient temperature over-low protection
PHHeating outdoor ambieent temperature over-high protection
L1Drive bus voltage over-high protection
L2Drive bus voltage over-low protection
L3Drive phase current overload fault
L4Phase current samping abnormal
U1IPM Over current protection
U3Compressor Over current protection
U4Over voltage protection
U5Low voltage protection
U7Over speed protection

Voltas Venture Slimline Tower AC Error Codes (Model: FAC241CZGG):

Its sleek & tall design helps to fit in small spaces. Additionally, it suits the style of your room interiors.

Voltas Venture Slimline Tower AC Error Codes
Voltas Venture Slimline Tower AC Error Codes
Error CodesProblem
E1The trouble of indoor unit room temperature sensor
E2The trouble of indoor unit pipe temperature sensor
E3The trouble of PG motor
E5Wired controller communication failure
E6The EEPRO of indoor unit error
1EThe trouble og outdoor unit room temperature sensor
2EThe trouble of outdoor unit pipe temperatue sensor
3EThe trouble of exhaust sensor
4EThe EEPRO of indoor unit error ( outdoor unit). Replace the module board of outdoor unit
8EThe trouble of PFC. Replace the module board of outdoor unit
H1Automatic defrosting
H3Stop for compressor overload protection
H4Overload protection
H5Stop for IPM module protection
H6PG motor does not operate ( indoor fan motor)
HCPFC overcurrent malfunction
L9High protection of power
LPIndoor and outdoor units cant match with each other
PHHigh voltage protection
PLLow voltage protection
C5Jumper cap malfunction

Comments

Popular posts from this blog

Rittal Air Conditioner Error Codes

  System messages are shown on the display screen of the Comfort controller via the displays A1 to A20 and E0. Rittal Air Conditioner Error Codes Error Codes System message Possible cause A1 Enclosure door open Door open or door limit switch incorrectly positioned A2 Internal temperature of enclosure too high Cooling capacity inadequate/unit undersized. Error as a consequence of messages A03 to A17. A3 Filter monitoring Filter mat soiled A4 Ambient temperature too high/too low Ambient temperature outside of admissible operating range (+10°C to +60°C) A5 Icing hazard Operational display in case of icing hazard. A6 PSAH pressure-operated switch Ambient temperature too high A7 Evaporator coil Lack of coolant; sensor in front of or behind condenser defective. A8 Condensate warning Condensate discharge kinked or blocked A9 Condenser fan blocked or defective Blocked or defective A10 Evaporator fan blocked or defective Blocked or defective A11 Compressor Compressor overloaded A12 Condense...

Samsung DVM-S VRF Error Codes

  DVM Digital Variable Multi VRF Systems Error Codes Samsung DVM VRF Error Codes Error code related indoor unit: Error Codes Explanation E-101 Indoor unit communication error. Indoor unit can not receive any data from outdoor unit. E-102 Communication error between indoor unit and outdoor unit. Displayed in indoor unit. E-108 Error due to repeated address setting (When 2 or more devices has same address within the network) E-121 Error on indoor temperature sensor of indoor unit (Short or Open) E-122 Error on EVA IN sensor of indoor unit (Short or Open) E-123 Error on EVA OUT sensor of indoor unit (Short or Open) E-128 EVA IN temperature sensor of indoor unit is detached from EVA IN pipe E-129 EVA OUT temperature sensor of indoor unit is detached from EVA OUT pipe E-130 Heat exchanger in/out sensors of indoor unit are detached E-135 RPM feedback error of indoor unit's cleaning fan E-149 Error due to AHU master indoor unit sensor setting. E-151 Error due to opened EEV of indoor unit ...

Panasonic VRF AC Error Codes and Troubleshooting

  Indoor unit is detecting error signal from remote controller (and system controller). Panasonic Mini VRF AC Error Codes and Troubleshooting Error Codes Meaning E01 Error in receiving serial communication signal. E02 Error in transmitting serial communication signal. E03 Indoor unit is detecting error signal from remote controller. E04 Error in receiving serial communication signal. When turning on the power supply, the number of connected indoor units does not correspond to the number set. E06 Error of the outdoor unit in receiving serial communication signal from the indoor unit. E08 Indoor unit address setting is duplicated. E09 Remote controller address connector. E12 Starting auto address setting is prohibited. This alarm message shows that the auto address connector CN-A.ADD is shorted while other RC line is executing auto address operation. E15 Error in auto address setting. E16 Error in auto address setting. E20 No indoor unit is connected during auto address setting. E24 ...