Vivax Air Conditioner Error Codes

 Split Air Conditioner and Residential Air Conditioners

Vivax Air Conditioner Error Codes
Vivax Air Conditioner Error Codes
Error CodesMeaning
C5Malfunction of connector jumper: Check if the connector jumper contacts properly. If the PCB is to be replaced, please take off the old for the new PCB.
F1Malfunction of indoor ambient temperature sensor :Check if indoor room temperature sensor is connected properly.
F2Malfunction of evaporator temperature sensor :Check if the evaporator temperature is connected properly.
H6Indoor fan block:Check if the terminal of the indoor motor is connected properly./Replace the fan motor or the indoor board if disabled.
H1Defrosting: It is normal.

Buttons on the cover is unavailable or insensitive: Please check whether the cover is closed completely

Moisture on air outlet : If the unit operates at high humidity for a long time, moisture will be generated on the air outlet grill and then drip off.

Noise from indoor unit: The noise emitted when the fan or compressor relay is switching on or off./When the defrosting operation is started or stopped, there is a sound of refrigerant flowing in the reverse direction.

Vivax Air Conditioner Name of Parts
Vivax Air Conditioner Name of Parts

Troubleshooting

The air conditioner is not user serviceable.Incorrect repair may cause electric shock or fire so please contact an authorized service center for professional repair. Following checks prior to contact may save your time and money.

Phenomenon: The unit does not operate

Troubleshooting: The unit does not operate if it is turned on immediately after it is turned off. This is to protect the unit. You should wait about 3 minutes.

Phenomenon: Odours are emitted

Troubleshooting:

  • Some odours may be emitted from the indoor unit. This is the result of room smells (such as furniture,tobacco,ect.) which have been taken into the air conditioner.
  • Consult authorized service center for cleaning if the odours still exist.

Phenomenon: Water flowing” noise

Troubleshooting: The swishing noise like water flowing is the refrigerant flowing inside the unit.

Phenomenon: Mist is emitted in COOL mode

Troubleshooting: During cooling operation, a thin mist may be seen emitted from the indoor unit due to high room temperature and humidity. After a period of time, the mist will disappear with the decrease of room temperature and humidity.

Phenomenon: Cracking noise

Troubleshooting: This is the sound of friction caused by expansion and/or contraction of panel or other parts due to the change of temperature

Phenomenon: The unit can not be started up

Troubleshooting:

  • Is the power cut off?
  • Is the power plug loose? ( if applicable )
  • Is the circuit protection device tripped off?
  • Is voltage higher or lower? (Tested by professionals)
  • Is the TIMER correctly used?

Phenomenon: Cooling/Heating effect is poor

Troubleshooting:

  • Is temperature setting appropriate?
  • Is the inlet or outlet blocked?
  • Is the filter dirty?
  • Is the window or the door open?
  • Is low fan speed set?
  • Are there heat sources in the room?

Phenomenon: Remote controller is not available

Troubleshooting:

  • Check if there is magnetic or electrical interference near the unit that may affecting operation of the controller. In this case, pull the plug out and reinsert it.
  • Is the remote controller within its operating range or obstructed? Check the condition of the batteries and replace them if necessary. Check if the remote controller is damaged.

Phenomenon: Water leakage of indoor unit

Troubleshooting:

  • The humidity is high.
  • Condensing water overflows.
  • Drain hose is loose.

Phenomenon: Water leakage of outdoor unit

Troubleshooting:

  • During cooling operation, water condensate is generated around the pipes and connection joints.
  • During defrosting operation,the thaw water flows out.
  • During heating operation,the water on the heat exchanger drips out

Phenomenon: Noise from indoor unit.

Troubleshooting:

  • The noise emitted when the fan or compressor relay is switching on or off.
  • When the defrosting operation is started or stopped, there is a sound of refrigerant flowing in the reverse direction.

Phenomenon: Indoor unit can not blow air

Troubleshooting:

  • In HEAT mode, when the temperature of indoor heat exchanger is very low, air flow is stopped in order to prevent cold air. (Within 2 minutes)
  • In HEAT mode, when the outdoor temperature is low or humidity is high, frost will be formed on the outdoor heat exchanger. The unit will defrost automatically and indoor unit will stop blowing air for 3-12 minutes.
  • During defrosting operation, water or vapour may be emitted.
  • In DRY mode, the indoor fan will stop blowing air for 3-12 minutes in order to avoid condensing water being vaporised again.

Phenomenon: Moisture on air outlet

Troubleshooting: If the unit operates at high humidity for a long time, moisture will be generated on the air outlet grill and then drip off.

Cleaning the Air Filter (every 3 months)

Cleaning the Air Filter
Cleaning the Air Filter

Do not to touch the fin of indoor unit during cleaning to avoid personal injury.

  1. Take down the air filter: Lift up the front panel. Pull the air filter downwards to take it off, as shown in Fig.(a, b).
  2. Clean the air filter: Use a vacuum cleaner to remove dust. If the filter are dirty, wash them with warm water and a mild detergent. Dry the filters in the shade.
  3. Reinstall the air filter: Reinstall the filters along the direction of arrowhead. Close the panel.

Vivax Air Conditioner Manual PDF

Comments

Popular posts from this blog

Rittal Air Conditioner Error Codes

  System messages are shown on the display screen of the Comfort controller via the displays A1 to A20 and E0. Rittal Air Conditioner Error Codes Error Codes System message Possible cause A1 Enclosure door open Door open or door limit switch incorrectly positioned A2 Internal temperature of enclosure too high Cooling capacity inadequate/unit undersized. Error as a consequence of messages A03 to A17. A3 Filter monitoring Filter mat soiled A4 Ambient temperature too high/too low Ambient temperature outside of admissible operating range (+10°C to +60°C) A5 Icing hazard Operational display in case of icing hazard. A6 PSAH pressure-operated switch Ambient temperature too high A7 Evaporator coil Lack of coolant; sensor in front of or behind condenser defective. A8 Condensate warning Condensate discharge kinked or blocked A9 Condenser fan blocked or defective Blocked or defective A10 Evaporator fan blocked or defective Blocked or defective A11 Compressor Compressor overloaded A12 Condense...

Samsung DVM-S VRF Error Codes

  DVM Digital Variable Multi VRF Systems Error Codes Samsung DVM VRF Error Codes Error code related indoor unit: Error Codes Explanation E-101 Indoor unit communication error. Indoor unit can not receive any data from outdoor unit. E-102 Communication error between indoor unit and outdoor unit. Displayed in indoor unit. E-108 Error due to repeated address setting (When 2 or more devices has same address within the network) E-121 Error on indoor temperature sensor of indoor unit (Short or Open) E-122 Error on EVA IN sensor of indoor unit (Short or Open) E-123 Error on EVA OUT sensor of indoor unit (Short or Open) E-128 EVA IN temperature sensor of indoor unit is detached from EVA IN pipe E-129 EVA OUT temperature sensor of indoor unit is detached from EVA OUT pipe E-130 Heat exchanger in/out sensors of indoor unit are detached E-135 RPM feedback error of indoor unit's cleaning fan E-149 Error due to AHU master indoor unit sensor setting. E-151 Error due to opened EEV of indoor unit ...

Panasonic VRF AC Error Codes and Troubleshooting

  Indoor unit is detecting error signal from remote controller (and system controller). Panasonic Mini VRF AC Error Codes and Troubleshooting Error Codes Meaning E01 Error in receiving serial communication signal. E02 Error in transmitting serial communication signal. E03 Indoor unit is detecting error signal from remote controller. E04 Error in receiving serial communication signal. When turning on the power supply, the number of connected indoor units does not correspond to the number set. E06 Error of the outdoor unit in receiving serial communication signal from the indoor unit. E08 Indoor unit address setting is duplicated. E09 Remote controller address connector. E12 Starting auto address setting is prohibited. This alarm message shows that the auto address connector CN-A.ADD is shorted while other RC line is executing auto address operation. E15 Error in auto address setting. E16 Error in auto address setting. E20 No indoor unit is connected during auto address setting. E24 ...