Skip to main content

Videocon Air Conditioner Error Codes

 Air conditioners had been installed self diagnosis system to display the information for the units.

Videocon Air Conditioner Error Codes
Videocon Air Conditioner Error Codes
Error CodeSeIf-check code of IuminotronSeIf-check information
Indicates ''dF'' or Heating icon flashFlicker 1 time/1sDefrost indication
Fan motor picture not runningFlicker 1 time/1sAnti cold wind
E2Flicker 1 times/8sRoom temperature sensor fault
E3Flicker 2 times/8sCoil temperature sensor
E8Flicker 3 tlmes/8sOver heat protection/Defrosting
E5Flicker 6 times/8sIndoor fan fault
E7Flicker 7 times/8sExternal feedback fault
E0Flicker 3times/8sOpen the door fault
E1Flicker 4 times/8sOutdoor tube temperature sensor faults
E6Flicker 6 times/8s(EEPROM) communication failures
FFFlicker 1 times/1sNorth American environment outside temperature erceeds the scope

Note: Above self check information is commonly applicable in our most air conditioners,but some are special,you can refer to the User’s Manual for information or contact the dealer or authorized maintenance people for help.

Selection of installation positions for outdoor unit

  • To install the outdoor unit at the places which can stand the load of the machine weight and will not cause big vibrations and noises;
  • To install the unit at the places not to be exposed to rain or direct sunshine, and the places with good ventilation;
  • The noises generated from the unit will not affect the neighboring places;
  • Do not install the unit on non-metal frame;
  • Not to install the unit at the places where there might occur the generation, inflow, stay or leakage of inflammable gases;
  • Pay attention to the drainage of the condensed water from the base plate during operations;
  • To avoid the air outlet being directly against the wind.
Videocon Air Conditioner Error Codes
Videocon Air Conditioner Error Codes

Selection of installation positions for indoor unit

  • To be installed at the position where the air delivered from the unit can reach every corner of the room;
  • To avoid being affected by the outdoor air;
  • To avoid blockage to the air inlet or outlet of the unit;
  • To avoid too much oil smoke or steam;
  • To avoid possible generation, inflow, lingering or leakage of flammable gases;
  • To avoid high-frequency facilities (such as high frequency arc welders, etc.);
  • To avoid the places where acid solutions are frequently used;
  • To avoid the places where some special sprayers (sulfides) are frequently used.
  • Not to install on top of the musical instruments,TV,computer etc.valuab|e appliance.
  • Not to install a fire alarming device near the air outlet of the unit (during operation, the fire alarm device might be erroneously triggered by the warm air from the unit);

Videocon VS5C3 Series Installation And Repair Manual PDF

Comments

Popular posts from this blog

Rittal Air Conditioner Error Codes

  System messages are shown on the display screen of the Comfort controller via the displays A1 to A20 and E0. Rittal Air Conditioner Error Codes Error Codes System message Possible cause A1 Enclosure door open Door open or door limit switch incorrectly positioned A2 Internal temperature of enclosure too high Cooling capacity inadequate/unit undersized. Error as a consequence of messages A03 to A17. A3 Filter monitoring Filter mat soiled A4 Ambient temperature too high/too low Ambient temperature outside of admissible operating range (+10°C to +60°C) A5 Icing hazard Operational display in case of icing hazard. A6 PSAH pressure-operated switch Ambient temperature too high A7 Evaporator coil Lack of coolant; sensor in front of or behind condenser defective. A8 Condensate warning Condensate discharge kinked or blocked A9 Condenser fan blocked or defective Blocked or defective A10 Evaporator fan blocked or defective Blocked or defective A11 Compressor Compressor overloaded A12 Condense...

Samsung DVM-S VRF Error Codes

  DVM Digital Variable Multi VRF Systems Error Codes Samsung DVM VRF Error Codes Error code related indoor unit: Error Codes Explanation E-101 Indoor unit communication error. Indoor unit can not receive any data from outdoor unit. E-102 Communication error between indoor unit and outdoor unit. Displayed in indoor unit. E-108 Error due to repeated address setting (When 2 or more devices has same address within the network) E-121 Error on indoor temperature sensor of indoor unit (Short or Open) E-122 Error on EVA IN sensor of indoor unit (Short or Open) E-123 Error on EVA OUT sensor of indoor unit (Short or Open) E-128 EVA IN temperature sensor of indoor unit is detached from EVA IN pipe E-129 EVA OUT temperature sensor of indoor unit is detached from EVA OUT pipe E-130 Heat exchanger in/out sensors of indoor unit are detached E-135 RPM feedback error of indoor unit's cleaning fan E-149 Error due to AHU master indoor unit sensor setting. E-151 Error due to opened EEV of indoor unit ...

Panasonic VRF AC Error Codes and Troubleshooting

  Indoor unit is detecting error signal from remote controller (and system controller). Panasonic Mini VRF AC Error Codes and Troubleshooting Error Codes Meaning E01 Error in receiving serial communication signal. E02 Error in transmitting serial communication signal. E03 Indoor unit is detecting error signal from remote controller. E04 Error in receiving serial communication signal. When turning on the power supply, the number of connected indoor units does not correspond to the number set. E06 Error of the outdoor unit in receiving serial communication signal from the indoor unit. E08 Indoor unit address setting is duplicated. E09 Remote controller address connector. E12 Starting auto address setting is prohibited. This alarm message shows that the auto address connector CN-A.ADD is shorted while other RC line is executing auto address operation. E15 Error in auto address setting. E16 Error in auto address setting. E20 No indoor unit is connected during auto address setting. E24 ...