Error CodesProblem
E0Indoor/outdoor communication fault
ECOutdoor communication fault
E1Room temperature sensor (IRT)
E2Indoor pipe (coil) temperature sensor (IPT)
E3Outdoor pipe (coil) temperature sensor (OPT)
E4System abnormal
E5Model configuration wrong
E6Indoor fan motor fault
E7Outdoor temperature sensor
E8Exhaust temperature sensor
E9Intelligent power module of drive and module fault
EFOutdoor fan motor fault (DC Motor)
EACurrent sensor fault
EEEEPROM fault
EPTemperature switch fault (on top of the compressor)
EUVoltage sensor fault
EHIntake temperature sensor
P1Overvoltage / undervoltage protection
P2Overcurrent protection
P4Exhaust overtemperature protection
P5Subcooling protection under cooling mode
P6Overheating protection under cooling mode
P7Overheating protection under heating mode
P8Outdoor overtemperature / undertemperature protection
P9Drive protection (software control )
P0Module protection (hardware control)

Protection and Failure Display;

  • When protection display is available, controller will show error code, digital LED shows error code and setting temperature by turns.
  • If there is more than one failure, it will show at first that in front of the error list.
  • Protection display function can be selected in hardware, and the default don’t display;
  • To insure of in and out communist is credibility, the failures relate to outdoor unit will remain failure state for 2 minutes max after recovered.
  • In all failures, only sensor failures don’t have to repower to cancel.

Error list;

TCL AC Error List

Protection display code list: 

TCL AC Display Code List

Outdoor failure display;

There is a LED on outdoor power board, when compressor is running; it is normally light; when no feedback of signal to power board from compressor, it will wink by lighting 1s and going out 1s. If failures happened, it will light 0.5s, go out 0.5s, winking several times and go out 3s for a cycle to indicate failures.

TCL AC Remote Controller
TCL AC Remote Controller

The failure list is the follow:

Wink time/Failure

1: IPM protection

2: higher or lower voltage

3: Over current

4: Discharge temperature too high

5: Outdoor coil temperature too high

6: Drive abnormity

7: Communication abnormity with indoor unit

8: Compressor over heat(switch on top of compressor)

9: Outdoor air temperature sensor failure

10: Outdoor coil temperature sensor failure

11: Outdoor discharge pipe temperature sensor failure

12: Voltage sensor failure

13: Current sensor failure

14: IPM abnormity

15: Outdoor communication abnormity

16: DC fan motor no feedback

17: defrosting

TCL Portable Air Conditioner Error Codes:

This appliance has a self diagnosis system to identify a number of malfunctions. If an error message is displayed, please refer to the below table.

TCL Portable Air Conditioner Error Codes
TCL Portable Air Conditioner Error Codes
Error CodesProblem
LtLow Temperature ( frost prevention). Action: The appliance is fitted with a frost protection device to avoid excessive formation of ice. The appliance starts up again automatically when the defrost process is completed.
PFProbe Failure ( sensor damaged). Action: If this is displayed, contact your local authorised service centre.
FtFull tank ( safety tank full). Action: Empty the internal safety tank.
ASIf the screen on the unit displays 'AS', the room temperature sensor has failed. Contact your Authorize Service Center.
ESIf the screen on the unit displays 'ES', the pipe temperature sensor has failed. Contact your Authorize Service Center.
P1If the screen on the unit displays 'P1', the water collection tank inside the unit should be full. If error repeats, contact your Authorize Service Center.

Model: TCLPAC10/TCLPAC12, TAC-08CPA/HC-TAC10CPA/HC

 

TCL Portable AC Error Codes List
TCL Portable AC Error Codes List

TCL Air Conditioner Troubleshooting

Problem: Air conditioner will not start

Possible Causes:

  1. The air conditioner plug is not completely inserted into the electrical outlet.
  2. The fuse is blown or the circuit breaker has tripped.
  3. Power failure.
  4. P1  appears in the display.
  5. Room temperature is less than the set temperature.

Solutions:

  1. Make sure electrical plug is plugged completely into alive. properly grounded outlet.
  2. Replace the fuse or reset the circuit breaker. Make sure that there are no other appliances on the same circuit.
  3. If a powerfailure occurs, turn the power OFF. When power is restored, wait 3 minutes before restarting the air conditioner.
  4. The water collection tank is full. Drain the tank and reset your settings.
  5. This is normal. The air conditioner automatically shuts offwhen the room equals or is less than (Cool mode) or is more than (Heat mode)the set temperature. Adjust the temperature setting, if needed.

Problem: Air conditioner does not cool properly

Possible Causes:

  1. Airflow is restricted.
  2. The airfilter is dirty.
  3. The room is very hot, or not enough time allowed for cooling.
  4. Cold air is escaping.
  5. Cooling coils have iced up.

Solutions:

  1. Make sure there is sufficient clearance around the air conditioner and that the air inlet and outlet are not blocked.
  2. Clean the air filter at least every two weeks.
  3. When first turned on, allow the air conditioner sufficient time to cool the room.
  4. Check for open furnace.floor registersmold air returns, open windows or doors.
  5. In especially cool, humid weather and when the air conditioner is running frequently or for extended periods, ice can form on the cooling coils, blocking air flow. It is normal, please adjust the temperature higher and High fan speed.

Problem: Air conditioner runs too often or too long

Possible Causes:

  1. Area to be cooled is too large for the air conditioner.
  2. Doors or windows are open.

Solutions:

  1. Consult your dealer for the air conditioner capacity necessary to cool the desired area.
  2. Make sure doors and windows are closed.

Cleaning The Filters:

To keep your air oonditionerworking efficiently, you should clean the filters every week of operation. Grasp the upper panel tab and take off the filterwhioh behind the grill of the back panel as shown the rightfig. Wash the filter using liquid dishwashing detergent and warm water. Rinse filter thorougth Gently shake excess waterfrom the filter. Be sure filter is thoroughly dry before replacing. 0r, instead of washing you may vacuum the filter clean. Replace the filter after the filter is dry.

TCL Portable AC Cleaning The Filters
TCL Portable AC Cleaning The Filters

The eebinet and front may be dusted with an oiI-free cloth or washed with a cloth dampened in a solution of warm water and mild liquid dishwashing detergent. Never use harsh cleaners, wax or polish on the cabinetfront. Be sure to wring excess waterfrom the cloth before wiping around the controls. Excess water in or around the controls may cause damage to the air conditioner.

TCL Split Type AC Electrical Schematic Diagram
TCL Split Type AC Electrical Schematic Diagram

 

Wiring of Inverter Split AC Unit
Wiring of Inverter Split AC Unit

TCL Portable Air Conditioner Manual PDF

TCL AC Manual PDF

TCL Split Type AC Manual PDF

Comments

Popular posts from this blog

Rittal Air Conditioner Error Codes

  System messages are shown on the display screen of the Comfort controller via the displays A1 to A20 and E0. Rittal Air Conditioner Error Codes Error Codes System message Possible cause A1 Enclosure door open Door open or door limit switch incorrectly positioned A2 Internal temperature of enclosure too high Cooling capacity inadequate/unit undersized. Error as a consequence of messages A03 to A17. A3 Filter monitoring Filter mat soiled A4 Ambient temperature too high/too low Ambient temperature outside of admissible operating range (+10°C to +60°C) A5 Icing hazard Operational display in case of icing hazard. A6 PSAH pressure-operated switch Ambient temperature too high A7 Evaporator coil Lack of coolant; sensor in front of or behind condenser defective. A8 Condensate warning Condensate discharge kinked or blocked A9 Condenser fan blocked or defective Blocked or defective A10 Evaporator fan blocked or defective Blocked or defective A11 Compressor Compressor overloaded A12 Condense...

Samsung DVM-S VRF Error Codes

  DVM Digital Variable Multi VRF Systems Error Codes Samsung DVM VRF Error Codes Error code related indoor unit: Error Codes Explanation E-101 Indoor unit communication error. Indoor unit can not receive any data from outdoor unit. E-102 Communication error between indoor unit and outdoor unit. Displayed in indoor unit. E-108 Error due to repeated address setting (When 2 or more devices has same address within the network) E-121 Error on indoor temperature sensor of indoor unit (Short or Open) E-122 Error on EVA IN sensor of indoor unit (Short or Open) E-123 Error on EVA OUT sensor of indoor unit (Short or Open) E-128 EVA IN temperature sensor of indoor unit is detached from EVA IN pipe E-129 EVA OUT temperature sensor of indoor unit is detached from EVA OUT pipe E-130 Heat exchanger in/out sensors of indoor unit are detached E-135 RPM feedback error of indoor unit's cleaning fan E-149 Error due to AHU master indoor unit sensor setting. E-151 Error due to opened EEV of indoor unit ...

Panasonic VRF AC Error Codes and Troubleshooting

  Indoor unit is detecting error signal from remote controller (and system controller). Panasonic Mini VRF AC Error Codes and Troubleshooting Error Codes Meaning E01 Error in receiving serial communication signal. E02 Error in transmitting serial communication signal. E03 Indoor unit is detecting error signal from remote controller. E04 Error in receiving serial communication signal. When turning on the power supply, the number of connected indoor units does not correspond to the number set. E06 Error of the outdoor unit in receiving serial communication signal from the indoor unit. E08 Indoor unit address setting is duplicated. E09 Remote controller address connector. E12 Starting auto address setting is prohibited. This alarm message shows that the auto address connector CN-A.ADD is shorted while other RC line is executing auto address operation. E15 Error in auto address setting. E16 Error in auto address setting. E20 No indoor unit is connected during auto address setting. E24 ...