SoleusAir Portable AC Error Codes

 Before installing and using your portable air conditioner, please read this owner’s manual carefully. Store this manual in a safe place for future reference.

SoleusAir Portable AC Error Codes
SoleusAir Portable AC Error Codes
Error CodesSolutions
E5Over Current Protection. Unplug for 10 minutes and then turn on the unit. If “E5” is still displayed, contact customer service.
H8The backup water tank is full. Drain the water tank.
F1The room air temperature sensor malfunction.. Please inform the maintenance man to maintain.
F2The tube temperature sensor malfunction. Please inform the maintenance man to maintain.
  • GM-PAC-08E3 / 8,000 BTU EVAPORATIVE AC
  • GM-PAC-10E2 / 10,000 BTU EVAPORATIVE AC
  • GM-PAC-12E1 / 12,000 BTU PORTABLE AC
  • GL-PAC-08E4/ 8,000 BTU EVAPORATIVE PORTABLE AC

 

SoleusAir Portable AC Control Display
SoleusAir Portable AC Control Display

Troubleshooting

SoleusAir Portable AC Remote Control
SoleusAir Portable AC Remote Control

Problem: The Air Conditioner will not start

Possible Causes:

  1. The air conditioner is unplugged or not connected well.
  2. The fuse is blown/circuit breaker is tripped.
  3. Power Failure
  4. The current interrupter device is tripped.

Solutions:

  1. Make sure the air conditioner plug is pushed completely into the outlet
  2. Check the house fuse/circuit breaker box and replace the fuse or reset the breaker.
  3. The unit will automatically restart when power is restored.
  4. Press the RESET button located on the power cord plug.

Problem: The Air Conditioner does not cool as it should

Possible Causes:

  1. Airflow is restricted
  2. The temperature control may not be set correctly.
  3. The air filter is dirty
  4. The room may be too warm
  5. Cold air is escaping
  6. The Evaporator is frozen

Solutions:

  1. Make sure there are no curtains, blinds, or furniture blocking the front of the air conditioner.
  2. Lower the set thermostat temperature.
  3. Clean the filter. See the Cleaning and Care Section of the manual.
  4. Please allow time for the room to cool down after turning on the air conditioner.
  5. Check for open furnace registers and cold air returns.
  6. The unit is defrosting and will resume operation when done.

Problem: The Air Conditioner displays the Timer hours but does not work

Possible Causes: Is the TIMER ON enabled?

Solutions: Cancel the TIMER or wait until the unit turns on.

Problem: The Remote Control is not working

Possible Causes:

  1. The batteries are inserted incorrectly
  2. The batteries may be dead

Solutions:

  1. Check the position of the batteries.
  2. Replace the batteries.

Problem: The LCD Display is showing “E5”

Possible Causes: Low Voltage Protection

Solutions: Unplug for 10 minutes and then turn on the unit. If “E5” is still displayed, contact customer service.

Problem: The LCD Display is showing “H8”

Possible Causes: The backup water tank is full

Solutions:

  1. Drain the water tank
  2. If the “H8” I still displayed after the water tank has been emptied, contact customer service.

GH-PAC-10E5/ 10,000 BTU HEAT PUMP AC

GH-PAC-12E1 / 12,000 BTU EVAPORATIVE AC

GB-PAC-08E4/ 8,000 BTU EVAPORATIVE AC

Gree products are sold through two major US home comfort brands; Soleus Air and Soleus Air Powered by Gree.

Model GM-PAC-08E3 Operating Instructions PDF

Model No. GH-PAC-10E5 Operating Instructions PDF

Model No. GL-PAC-08E4 Operating Instructions PDF

Comments

Popular posts from this blog

Rittal Air Conditioner Error Codes

  System messages are shown on the display screen of the Comfort controller via the displays A1 to A20 and E0. Rittal Air Conditioner Error Codes Error Codes System message Possible cause A1 Enclosure door open Door open or door limit switch incorrectly positioned A2 Internal temperature of enclosure too high Cooling capacity inadequate/unit undersized. Error as a consequence of messages A03 to A17. A3 Filter monitoring Filter mat soiled A4 Ambient temperature too high/too low Ambient temperature outside of admissible operating range (+10°C to +60°C) A5 Icing hazard Operational display in case of icing hazard. A6 PSAH pressure-operated switch Ambient temperature too high A7 Evaporator coil Lack of coolant; sensor in front of or behind condenser defective. A8 Condensate warning Condensate discharge kinked or blocked A9 Condenser fan blocked or defective Blocked or defective A10 Evaporator fan blocked or defective Blocked or defective A11 Compressor Compressor overloaded A12 Condense...

Samsung DVM-S VRF Error Codes

  DVM Digital Variable Multi VRF Systems Error Codes Samsung DVM VRF Error Codes Error code related indoor unit: Error Codes Explanation E-101 Indoor unit communication error. Indoor unit can not receive any data from outdoor unit. E-102 Communication error between indoor unit and outdoor unit. Displayed in indoor unit. E-108 Error due to repeated address setting (When 2 or more devices has same address within the network) E-121 Error on indoor temperature sensor of indoor unit (Short or Open) E-122 Error on EVA IN sensor of indoor unit (Short or Open) E-123 Error on EVA OUT sensor of indoor unit (Short or Open) E-128 EVA IN temperature sensor of indoor unit is detached from EVA IN pipe E-129 EVA OUT temperature sensor of indoor unit is detached from EVA OUT pipe E-130 Heat exchanger in/out sensors of indoor unit are detached E-135 RPM feedback error of indoor unit's cleaning fan E-149 Error due to AHU master indoor unit sensor setting. E-151 Error due to opened EEV of indoor unit ...

Panasonic VRF AC Error Codes and Troubleshooting

  Indoor unit is detecting error signal from remote controller (and system controller). Panasonic Mini VRF AC Error Codes and Troubleshooting Error Codes Meaning E01 Error in receiving serial communication signal. E02 Error in transmitting serial communication signal. E03 Indoor unit is detecting error signal from remote controller. E04 Error in receiving serial communication signal. When turning on the power supply, the number of connected indoor units does not correspond to the number set. E06 Error of the outdoor unit in receiving serial communication signal from the indoor unit. E08 Indoor unit address setting is duplicated. E09 Remote controller address connector. E12 Starting auto address setting is prohibited. This alarm message shows that the auto address connector CN-A.ADD is shorted while other RC line is executing auto address operation. E15 Error in auto address setting. E16 Error in auto address setting. E20 No indoor unit is connected during auto address setting. E24 ...