Sharp Air Conditioner Error Codes

 Sharp Air Conditioner Error Codes:

Sharp Air Conditioner Error Codes
Sharp Air Conditioner Error Codes
Error CodesProblem
EEButtons are locked
E0Water pump malffunction
E1High pressure protection of compressor
E2Indoor anti-frozen of compressor
E3Low pressure protection of compressor
E4Air discharge high-temperature protection of compressor
E5Overload protection of compressor
E6Transmit malfunction
E8Indoor fan protection
E9Water flow protection
FFConnected control communications Failure
F0Malfunction of indoor environment sensor at air return vent
F1Evaporator sensor malfunction
F2Condenser sensor malfunction
F3Outdoor environment sensor malfunction
F4Malfunction of air discharge sensor
F5Malfunction of environment sensor on displayer
eeMalfunction of outdoor drive memory chip. Outdoor drive board.
H3
Compressor over load protection. Compressor overload switch.
H4Overload protection. Evaporator temperature, condenser temperature.
H6
Malfunction of outdoor fan motor. Outdoor fan motor.
U7Direction changing malfunction of 4-way valve.
P6Communicatio n malfunction between main control and drive.
EEMalfunction of outdoor main control memory chip. Outdoor main control board.

ES: If this display reads ”ES” or ”AS”, a sensor has failed. Contact your Authorized Sharp Service Center.

Sharp Air Conditioner Remote Control
”ES” or ”AS”, a sensor has failed

Sharp Air Conditioner Troubleshooting

SymptomTroubleshooting
Air conditioner does not run if attem pt to immediately restart after a stop.To protect the air conditioner upon immediate restart after a stop, the microcomputer controller will delay the unit for 3 minutes before the air conditioner will run.
Air conditioner blows out bad smell when it is initially started.The air conditioner itself has no bad smell. If a bad smell has been accumulated from the environment, clean the airfilter.
You may hear ''Water Flowing'' noiseWhen the air conditioner is started, or the compressor is started or stopped during running or the air conditioner is stopped, sometimes you may hear fluid gurgling noises. This is not a fault - it is the sound offlowing refrigerant.
Sometimes a thin mist will flow out of the outlet when air conditioner is running under cooling mode.This might occur when indoor temperature and humidity are high. This is because the indoor air is quickly cooled down. After a period of time, the mist will disappear with the decrease of indoor temperature and humidity.
You may hear a slight cracking sound when the air conditioner is started or stopped.This is the sound of friction caused by expansion and/or contraction of panel or other parts due to the change of temperature.
The unit will not runHas the power been shut down? Has the circuit breaker device tripped off? Is the Timer correctly used? Have the wiring or connections been a damaged?P
Cooling (Heating) efficiency is not good.Is Temp. setting suitable? Are inlet and outlet vents obstructed? Are the windows and doors closed? Is the fa n speed_set at low speed? Is there too much dust accumulated and obstructing the filter?
Wireless remote control is not workingCheck that there is no magnetic or electrical interference near the main unit that may be affecting the operation of the controller.
Water is dripping or leaking from the indoor unitThe air humidity is on the high side. Condensing water has overflowed. The connection of indoor unit drainage pipe has been loosened.
Noise from indoor unitFan or compressor relay is switching on or off. When defrosting is started or stopped, there is a sound of refrigerant flowing in the reverse direction.
Moisture on air outlet ventIf unit is running under high humidity for a long time, moisture will be condensed on the air outlet grill and may drip off.
Sharp Air Conditioner Remote Control
Sharp Air Conditioner Remote Control

Main board dual 8 numeral tube Display Codes for Outdoor Unit of 09~48k

Malfunction ItemIndoor-Outdoor Unit Display
DC busbar over-voltage protectionPH
IPM or PFC over-temperature protectionP8
Current sense circuit errorPc
IPM or PFC temperature sensor errorP7
Compressor current protectionP5
DC busbar under-voltage protectionPL
Compressor startup failureLc
Drive module resetP0
Compressor motor desynchronizingH7
Phase lossLd
Drive-to-main-control communication errorP6
IPM protectionH5
Compressor overload protectionH3
AC current protection (input side)PA
Charging circuit errorPU
PFC protectionHC(48k only)
DC fan errorH6
Input AC voltage abnormalityPP
Driving board memory chip erroree(09-42k)

Sharp Air Conditioner Manual PDF

Sharp Air Conditioner Service Manual PDF

Comments

Popular posts from this blog

Rittal Air Conditioner Error Codes

  System messages are shown on the display screen of the Comfort controller via the displays A1 to A20 and E0. Rittal Air Conditioner Error Codes Error Codes System message Possible cause A1 Enclosure door open Door open or door limit switch incorrectly positioned A2 Internal temperature of enclosure too high Cooling capacity inadequate/unit undersized. Error as a consequence of messages A03 to A17. A3 Filter monitoring Filter mat soiled A4 Ambient temperature too high/too low Ambient temperature outside of admissible operating range (+10°C to +60°C) A5 Icing hazard Operational display in case of icing hazard. A6 PSAH pressure-operated switch Ambient temperature too high A7 Evaporator coil Lack of coolant; sensor in front of or behind condenser defective. A8 Condensate warning Condensate discharge kinked or blocked A9 Condenser fan blocked or defective Blocked or defective A10 Evaporator fan blocked or defective Blocked or defective A11 Compressor Compressor overloaded A12 Condense...

Samsung DVM-S VRF Error Codes

  DVM Digital Variable Multi VRF Systems Error Codes Samsung DVM VRF Error Codes Error code related indoor unit: Error Codes Explanation E-101 Indoor unit communication error. Indoor unit can not receive any data from outdoor unit. E-102 Communication error between indoor unit and outdoor unit. Displayed in indoor unit. E-108 Error due to repeated address setting (When 2 or more devices has same address within the network) E-121 Error on indoor temperature sensor of indoor unit (Short or Open) E-122 Error on EVA IN sensor of indoor unit (Short or Open) E-123 Error on EVA OUT sensor of indoor unit (Short or Open) E-128 EVA IN temperature sensor of indoor unit is detached from EVA IN pipe E-129 EVA OUT temperature sensor of indoor unit is detached from EVA OUT pipe E-130 Heat exchanger in/out sensors of indoor unit are detached E-135 RPM feedback error of indoor unit's cleaning fan E-149 Error due to AHU master indoor unit sensor setting. E-151 Error due to opened EEV of indoor unit ...

Panasonic VRF AC Error Codes and Troubleshooting

  Indoor unit is detecting error signal from remote controller (and system controller). Panasonic Mini VRF AC Error Codes and Troubleshooting Error Codes Meaning E01 Error in receiving serial communication signal. E02 Error in transmitting serial communication signal. E03 Indoor unit is detecting error signal from remote controller. E04 Error in receiving serial communication signal. When turning on the power supply, the number of connected indoor units does not correspond to the number set. E06 Error of the outdoor unit in receiving serial communication signal from the indoor unit. E08 Indoor unit address setting is duplicated. E09 Remote controller address connector. E12 Starting auto address setting is prohibited. This alarm message shows that the auto address connector CN-A.ADD is shorted while other RC line is executing auto address operation. E15 Error in auto address setting. E16 Error in auto address setting. E20 No indoor unit is connected during auto address setting. E24 ...