Indoor Unit Error Display:

Error CodesLED Status
E0EEPROM parameter error
E1Indoor / outdoor units communication protection
E2Zero-crossing signal error
E3Indoor fan speed out of control
E5Open or short circuit of outdoor temperature sensor or outdoor unit EEPROM parameter error
E6Open or short circuit of room or evaporator temperature sensor
E7Outdoor fan speed out of control
P0IBM malfunction or IGBT over-strong current protection
P1Over voltage or too low voltage protection
P2Temperature protection of compressor top.
P4Inverter compressor drive error

Outdoor unit error display:

On the outdoor PCB, there are two LED lights. One is green, the other is red. You can judge what the error is through the status of the two lights.

Indoor Unit Display: P1

LED 6 (Green) Light,  LED 5 (RED) Light: Over voltage or too lows or too voltage protection

Indoor Unit Display: P2

LED 6 (Green) Light,  LED 5 (RED) Flash: Over voltage or too lows or too voltage protection

Indoor Unit Display: P4

LED 6 (Green) Off,  LED 5 (RED) Flash: Inverter compressor drive error

Indoor Unit Display: P4

LED 6 (Green) Flash,  LED 5 (RED) Light: Inverter compressor drive error

Indoor Unit Display: P4

LED 6 (Green) Flash,  LED 5 (RED) Flash: Inverter compressor drive error

Indoor Unit Display: P0

LED 6 (Green) Flash,  LED 5 (RED) Off: IBM malfuntion or IGBT over-strong current protection

Indoor Unit Display: Stand by

LED 6 (Green) Light,  LED 5 (RED) Off: Stand by

Outdoor unit error display
Outdoor unit error display

Troubleshooting

Malfunctions: Unit does not start

Cause:

  1. Power cut
  2. Unit may have become Unplugged
  3. Fuse may have blown
  4. Battery in Remote controller may have been exhausted
  5. The time you have set with timer is incorrect

What should be done:

  1. Wait for power to be restored
  2. Check that plug is securely in wall receptacle
  3. Replace the fuse
  4. Replace the battery
  5. Wait or cancel timer setting

Malfunctions: Unit not cooling or heating (Cooling/ heating models only) room very well while air flowing out from the air cond tioner

Cause:

  1. Inappropriate temperature setting
  2. Air filter is blocked
  3. Doors or Windows are open
  4. Air inlet or outlet of indoor or outdoor unit has been blocked
  5. Compressor 3 minutes protection has been activated

What should be done:

  1. Set temperature correctly. For detailed method please refer to ”Using remote control” section
  2. Clean the air filter
  3. Close the doors or windows
  4. Clear obstructions away first, then restart the unit
  5. Wait

Malfunctions: The unit starts and stops frequently

Cause:

  1. There’s too much or too little refrigerant in the system
  2. Incompressible gas or moisture has entered the system.
  3. The compressor is broken
  4. The voltage is too high or too low

What should be done:

  1. Check for leaks and recharge the system with refrigerant.
  2. Evacuate and recharge the system with refrigerant
  3. Replace the compressor
  4. Install a manostat to regulate the voltage

Issue: Both the indoor unit and outdoor unit make noises

Possible Causes:

  1. Low hissing sound during operation: This is normal and is caused by refrigerant gas flowing through both indoor and outdoor units.
  2. Low hissing sound when the system starts, has just stopped running, or is defrosting: This noise is normal and is caused by the refrigerant gas stopping or changing direction.
  3. Squeaking sound: Normal expansion and contraction of plastic and metal parts caused by temperature changes during operation can cause squeaking noises.

Diagnosis and Solution

EEPROM parameter error diagnosis and solution

EEPROM parameter error diagnosis and solution
EEPROM parameter error diagnosis and solution

 

Fan speed has been out of control diagnosis

Fan speed has been out of control diagnosis
Fan speed has been out of control diagnosis

Open or short circuit of temperature sensor diagnosis and solution

Open or short circuit of temperature sensor diagnosis and solution
Open or short circuit of temperature sensor diagnosis and solution

IGBT over-strong current protection diagnosis and solution

IGBT over-strong current protection diagnosis and solution
IGBT over-strong current protection diagnosis and solution

Over voltage or too low voltage protection diagnosis and solution

Over voltage or too low voltage protection diagnosis and solution
Over voltage or too low voltage protection diagnosis and solution

High temperature protection of compressor top diagnosis and solution

High temperature protection of compressor top diagnosis and solution
High temperature protection of compressor top diagnosis and solution

Inverter compressor drive error diagnosis and solution

Inverter compressor drive error diagnosis and solution
Inverter compressor drive error diagnosis and solution

Zero crossing detection error

This is alarm signal when the main chip can’t detect over-zero signal. When such failure occurs, the main control board must have fault.

Display function

Icon explanation on indoor display board.

Senville AC Display function
Senville AC Display function

OPERATION indication lamp: This lamp illuminates when the air conditioner is in operation.

AUTO indication lamp: Lights up during the Auto operation.

Ion indication lamp (optional function)Lights up when Clean Air feature is activated and Ionizer can generate abundant anions to fill the room with refreshing and natural air.

TIMER indication lamp: Lights up during Timer operation.

DEFROST indication lamp (For cooling & heating models only): Lights up when the air conditioner starts defrosting automatically or when the warm air control feature is activated in heating operation.

DIGITAL DISPLAY: Displays the current setting temperature and malfunction/protection code when the air conditioner is in operation.

Frequency display: This display is separated into five zones. The zones illuminate based on the compressor current frequency. For example, higher frequency will illuminate more zones.

Senville indoor symbol meaning
Senville indoor symbol meaning

Senville Air Conditioner Remote Control Symbol Meaning

Senville Air Conditioner Remote Control Symbol Meaning
Senville Air Conditioner Remote Control Symbol Meaning

Senville AURA Series Air Conditioner Manual PDF

Senville AURA Series Multi-Zone Air Conditioner Manual PDF

Senville LETO Series Air Conditioner Manual PDF

Source: senville.com

Comments

Popular posts from this blog

Rittal Air Conditioner Error Codes

  System messages are shown on the display screen of the Comfort controller via the displays A1 to A20 and E0. Rittal Air Conditioner Error Codes Error Codes System message Possible cause A1 Enclosure door open Door open or door limit switch incorrectly positioned A2 Internal temperature of enclosure too high Cooling capacity inadequate/unit undersized. Error as a consequence of messages A03 to A17. A3 Filter monitoring Filter mat soiled A4 Ambient temperature too high/too low Ambient temperature outside of admissible operating range (+10°C to +60°C) A5 Icing hazard Operational display in case of icing hazard. A6 PSAH pressure-operated switch Ambient temperature too high A7 Evaporator coil Lack of coolant; sensor in front of or behind condenser defective. A8 Condensate warning Condensate discharge kinked or blocked A9 Condenser fan blocked or defective Blocked or defective A10 Evaporator fan blocked or defective Blocked or defective A11 Compressor Compressor overloaded A12 Condense...

Samsung DVM-S VRF Error Codes

  DVM Digital Variable Multi VRF Systems Error Codes Samsung DVM VRF Error Codes Error code related indoor unit: Error Codes Explanation E-101 Indoor unit communication error. Indoor unit can not receive any data from outdoor unit. E-102 Communication error between indoor unit and outdoor unit. Displayed in indoor unit. E-108 Error due to repeated address setting (When 2 or more devices has same address within the network) E-121 Error on indoor temperature sensor of indoor unit (Short or Open) E-122 Error on EVA IN sensor of indoor unit (Short or Open) E-123 Error on EVA OUT sensor of indoor unit (Short or Open) E-128 EVA IN temperature sensor of indoor unit is detached from EVA IN pipe E-129 EVA OUT temperature sensor of indoor unit is detached from EVA OUT pipe E-130 Heat exchanger in/out sensors of indoor unit are detached E-135 RPM feedback error of indoor unit's cleaning fan E-149 Error due to AHU master indoor unit sensor setting. E-151 Error due to opened EEV of indoor unit ...

Panasonic VRF AC Error Codes and Troubleshooting

  Indoor unit is detecting error signal from remote controller (and system controller). Panasonic Mini VRF AC Error Codes and Troubleshooting Error Codes Meaning E01 Error in receiving serial communication signal. E02 Error in transmitting serial communication signal. E03 Indoor unit is detecting error signal from remote controller. E04 Error in receiving serial communication signal. When turning on the power supply, the number of connected indoor units does not correspond to the number set. E06 Error of the outdoor unit in receiving serial communication signal from the indoor unit. E08 Indoor unit address setting is duplicated. E09 Remote controller address connector. E12 Starting auto address setting is prohibited. This alarm message shows that the auto address connector CN-A.ADD is shorted while other RC line is executing auto address operation. E15 Error in auto address setting. E16 Error in auto address setting. E20 No indoor unit is connected during auto address setting. E24 ...