Sea Breeze AC Mini Split Error Codes

 This air conditioning system has been provided with built in self diagnostic error codes. Please refer to the following table for error code definitions:

Sea Breeze AC Mini Split Error Codes
Sea Breeze AC Mini Split Error Codes

For Sea Breeze Models: 9MH46ZIGX Evaporator- 12MH46ZIGX Evaporator- 18MH46ZIGX Evaporator- 34MH46ZOGX Condenser – 24MH46ZOGX Condenser

Indoor Unit Error Codes:

Error CodesMeaning
H4System Overload
H3Compressor Overload Protection
H5IPM Protection
E1High Pressure Protection
E2Anti-Freezing Protection
E4Exhaust Protection
E5Over Current Protection
E7Mode Conflict
E6Communication Malfunction
H1Defrost or Oil Return of Heat
F1Indoor Ambient Sensor Malfunction
F2Indoor Tube Sensor Malfunction
F3Outdoor Ambient Sensor Malfunction
F4Outdoor Tube Sensor Malfunction
F5Outdoor Exhaust Sensor Malfunction
H7Failure Startup
HCPFC Malfunction PFC
HEDemagnetizing Protection for Compressor
F6Frequency Drop for Overload
F8Frequency Drop for Over Current Protection
F9Frequency Drop for Exhaust Protection
H0Frequency Drop for Heating High Temperature Protection
E9Anti-Cold Protection
F7Oil Return of Cooling

Troubleshooting

The first step in troubleshooting is to disconnect power for 30 seconds to allow the unit to reset. If this does not rectify the problem proceed with the troubleshooting chart below.

Problem: The unit does not run.

Troubleshooting:

  • Is the power off?
  • Is the circuit protection device tripped?
  • Is voltage too high or low? (Tested by a professional)
  • Is the Timer on?
  • A 3 minute delay occurs before each compressor start.

Problem: Cooling and or Heating efficiency is not good.

Troubleshooting:

  • Is temperature setting correct?
  • Are the inlet or outlet vents obstructed?
  • Is the filter clean?
  • Are windows and doors closed?
  • Is fan set to low speed?
  • Is there a heat source in the room?

Problem: Wireless remote control is not working.

Troubleshooting:

  • Reset unit. Disconnect main power for 30 seconds then reapply.
  • Is it within receiving range? Is it obstructed?
  • Replace the batteries.
  • Is remote control damaged?

Problem: Water leaking into room.

Troubleshooting:

  • The air humidity is excessively high. Check to see if all windows and doors are closed.
  • Call service Tech if not corrected by the above action.

Problem: Water leakage in outdoor unit.

Troubleshooting:

  • When the unit is running in Auto Defrosting mode, ice will thaw and drip into pan.
  • When the unit is running in HEAT mode, the water adhered to the condenser coil drains into pan.

Problem: Noise from indoor unit emitted.

Troubleshooting:

  • When defrosting is started or stopped, it will make a sound. This is due to the refrigerant flow reversing directions.
  • Normal refrigerant flowing in unit.

Notes:

  1. If E7 error code occurs, see the AUTO mode section in Operators Manual on page 7 .
  2. An audible beep will be heard, when a button is pressed, if the remote control is communicating with the receiver.

Selecting locations for the Indoor unit

  1. Determine the best location for mounting the Indoor unit. Ensure the dimensions requirement indicated be the arrows are followed.
  2. Paying close attention to the air circulation in the room, these units throw air approximately 15ft. Ensure that no obstacles impede airflow.
  3. Do not mount this unit close to a heat source or a doorway.
Best Location For Ac Unit In Your Room
Best Location For Ac Unit In Your Room

Selecting location for Outdoor unit

  1. Determine the best location for mounting the outdoor unit. Ensure the dimensions requirement indicated be the arrows are followed.
  2. Do not mount this unit close to combustibles or heat sources.
  3. Although this unit is fairly quiet when in operation, do not mount where noise issues could be a problem.

Sea Breeze AC Manual PDF

Comments

Popular posts from this blog

AUX Air Con Error Codes

Aux Air Conditioner Troubleshooting November 3, 2018 at 9:18 pm If the following phenomena are found, the problem is not from the  air-conditioner itself. Problems The motor is heard operating but the air-conditioner dose not work when the indoor unit is powered on Causes Since the air-conditioner is powered on, it will come to working condition as long as you press the ON/OFF button of the remote control and the Signal is well received. Problems The compressor stops running but the indoor fan motor keeps working when it is at cooling mode with the indoor temperature higher than set temperature. Causes If you turn off the air-conditioner and restart it immediately, it will return to normal in 3 minutes, after that, the air-conditioner will automatically adjust the indoor fan speed to what you set. Problems The compressor works discontinuously at dehumidifying mode. Causes The air-conditioner will automatically control the working of the compressor according to the insi

Hisense VRF Air Conditioner Error Codes

 Inverter-driven Multi-split Air Conditioner (Heat Pump) Error Codes Problem 01 Activation of Protection Device (Float Switch). Activation of Float Switch. 02 Activation of Protection Device (High Pressure Cut). Activation of PSH. 03 Abnormality between Indoor and Outdoor. Incorrect Wiring, Loose Terminals, Disconnect Wire, Blowout of Fuse, Outdoor Unit Power OFF. 04 Abnormality between Inverter PCB and Outdoor PCB. Inverter PCB - Outdoor PCB Transmission Failure. 04. Abnormality between Fan Controller and Outdoor PCB. Fan Controller - Outdoor PCB Transmission Failure. 05 Abnormality Power Source Phases. Incorrect Power Source, Connection to Reversed Phase, Open-Phase. 06 Abnormal Inverter Voltage. Outdoor Voltage Drop, Insufficient Power Capacity. 06. Abnormal Fan Controller Voltage. Outdoor Voltage Drop, Insufficient Power Capacity. 07 Decrease in Discharge Gas Superheat. Excessive Refrigerant Charge, Failure of Thermistor, Incorrect Wiring, Incorrect Piping Connection, Expansion Val

Samsung DVM-S VRF Error Codes

  DVM Digital Variable Multi VRF Systems Error Codes Samsung DVM VRF Error Codes Error code related indoor unit: Error Codes Explanation E-101 Indoor unit communication error. Indoor unit can not receive any data from outdoor unit. E-102 Communication error between indoor unit and outdoor unit. Displayed in indoor unit. E-108 Error due to repeated address setting (When 2 or more devices has same address within the network) E-121 Error on indoor temperature sensor of indoor unit (Short or Open) E-122 Error on EVA IN sensor of indoor unit (Short or Open) E-123 Error on EVA OUT sensor of indoor unit (Short or Open) E-128 EVA IN temperature sensor of indoor unit is detached from EVA IN pipe E-129 EVA OUT temperature sensor of indoor unit is detached from EVA OUT pipe E-130 Heat exchanger in/out sensors of indoor unit are detached E-135 RPM feedback error of indoor unit's cleaning fan E-149 Error due to AHU master indoor unit sensor setting. E-151 Error due to opened EEV of indoor unit