Perfect Aire Dehumidifier Error Codes and Troubleshooting

 If the display shows any of the following error codes, unplug the unit for at least 5 minutes and plug it back in.

  
E1Room Sensor failure
E2Defroster Sensor failure
E3Humidity Sensor failure
ECUnit malfunction, Make sure the temperature of the working environment is between 41°F/5°C and 95°F/35°C. If not, please operate the unit under the correct stated temperature. If on a concrete floor, unplug and elevate unit a few inches off the floor; plug back into outlet and power on.
P2Bucket is full or not in the correct position. Empty the bucket and replace it in the proper position. Ensure float switch and foam are secured properly in bucket.
ESTemperature sensor error, Unplug the unit for at least 5 minutes and plug it back in.
ASHumidity sensor error Unplug the unit for at least 5 minutes and plug it back in.
Perfect Aire Dehumidifier Error Codes and Troubleshooting
Perfect Aire Dehumidifier Error Codes and Troubleshooting

Troubleshooting

ISSUEPOSSIBLE CAUSES
Unit Does Not Start• Make sure the dehumidifier’s plug is pushed completely into the outlet. • Check the fuse/circuit breaker box in your home. • The bucket is full and needs to be emptied. • The water bucket is not in the proper position.
Dehumidifier’s Bucket Full Light Is Iuminated Even Though Bucket Is Empty• Verify drain plug has not been removed from back of unit if using the bucket to collect water. • Check float switch (inch length tab in top of unit behind bucket) to ensure it is not cracked, broken or stuck. The switch is located on the right side behind the bucket when you are facing the unit. • Check that unit is level and the filter, vents and bucket are thoroughly clean. • Ensure float is snapped properly into place inside the bucket. (See page 3 for description of “float” piece.) • Unplug unit for at least 5 minutes. Remove and return bucket securely, plug unit back in, then turn on unit.
Dehumidifier Not Drawing WaterBe sure unit is not too large or too small for the area of the room. • Allow enough time for unit to remove moisture. • Set humidity low enough to ensure moisture removal. • Setting may be the same as actual humidity in room, thus no moisture to remove. • Be sure all doors, windows and other openings are securely closed. • Be sure unit is level and that there is sufficient air circulation around the unit, as well as between unit and floor. • Make sure unit is level and that there are no curtains, blinds, or furniture blocking the unit. • Check that room temperature is 41ºF or above. • If unit is near a heat source, such as a clothes dryer, etc., relocate unit. • Clean the air filter and air outlet.
Auto Defrost Displays Repeatedly• Turn off unit and unplug 4-6 hours. • Plug unit back in. Run in normal mode (no Turbo fan, not on Continuous operation). • Be sure unit humidity is not set too low, unit is not sitting on too cold of a floor and unit is not being used in too cold of a room. (Room should be 41ºF or above.) • Be sure there is sufficient air circulation between the unit and the surface on which it is sitting.
Dehumidifier Constantly Cycles On/off• Be sure unit is not too large or too small for the area of the room. • Using unit in much less than its stated coverage will likely cause it to go on and off more frequently. Using too small of a unit will cause it to run constantly. • If the humidity setting and actual humidity in room are cycling right around the same, the unit will go off and on accordingly. • The fan will run for a few minutes after the compressor shuts off. • Check that unit is level and the filter, vents and bucket are thoroughly clean and nothing is obstructing them. • Be sure all doors, windows and other openings are securely closed. • Ensure there is sufficient air circulation around the unit, as well as between unit and floor. • Unplug unit for at least 5 minutes. Plug back in unit, remove and return bucket to dehumidifier and turn on.
Unit Makes A Loud Noise When Operating• Make sure the air filter is clean and not clogged. • Make sure the unit is upright (not tilted) and on a flat, level surface.
Dehumidifier Always Running• Be sure unit is not too large or too small for the area of the room. • Allow enough time for unit to remove moisture. • If humidity in room is above the set humidity, then unit will run. • Be sure all doors, windows and other openings are securely closed. • Be sure unit is level and that there is sufficient air circulation around the unit, as well as between unit and floor. • Make sure there are no curtains, blinds, or furniture blocking the unit. • If unit is near a source of moisture, such as a sink, shower, washing machine, etc., then relocate unit. • Check that filter, vents and bucket are thoroughly clean
Continuous Drain Not Working Properly• If using a garden hose (not included), be sure hose is CLEAN, pliable and no longer than 6 feet in length (recommended). Clear tubing with sizing of 0.5 inches (13 mm) for inner diameter is recommended. (Tubing not included.) • Hose should be secure on both ends, being especially mindful that it is pushed all the way onto connector piece inside unit. • Hose should exit through the back of unit and always be positioned at a DOWNWARD slope to the desired drain location. • Check that filter, vents and bucket are thoroughly clean. • Be sure nothing is obstructing hose connection and there are no kinks or tears in any of the hosing. • Ensure unit is level and not tilted forward and that bucket is pushed in all the way. Though the unit may appear level, if the surface it sits on is even slightly uneven and the front of the unit is tilted downward, continuous draining may not work. If necessary, slightly prop up the front of the unit, taking care that the unit does not fall backward. • If water is going into bucket instead of hose, the unit is working properly. Please double check all of the above and/or un-hook hosing set-up and start again.
Water On Floor• Check the hose connection points to make sure they are not loose. • Ensure float is snapped properly into place inside the bucket. (See page 3 for description of “float” piece.) • Ensure foam piece is securely inside float and has not been removed (1PED50 and 1PED70 models only
A Hissing Noise Or Hollow SoundThis sound is normal. It is generated from the refrigerant flowing in the pipes.
A Squeaking NoiseThis noise is generated from the unit when it expands or contracts with temperature changes.
The Unit Does Not Immediately Start Or Change Operating ModeTo prevent overloading the compressor motor, after the unit has stopped (or entered a mode), it cannot resume operation (or enter a different mode) in the first 3 minutes afterwards.

Perfect Aire Dehumidifier Manual PDF

Comments

Popular posts from this blog

Rittal Air Conditioner Error Codes

  System messages are shown on the display screen of the Comfort controller via the displays A1 to A20 and E0. Rittal Air Conditioner Error Codes Error Codes System message Possible cause A1 Enclosure door open Door open or door limit switch incorrectly positioned A2 Internal temperature of enclosure too high Cooling capacity inadequate/unit undersized. Error as a consequence of messages A03 to A17. A3 Filter monitoring Filter mat soiled A4 Ambient temperature too high/too low Ambient temperature outside of admissible operating range (+10°C to +60°C) A5 Icing hazard Operational display in case of icing hazard. A6 PSAH pressure-operated switch Ambient temperature too high A7 Evaporator coil Lack of coolant; sensor in front of or behind condenser defective. A8 Condensate warning Condensate discharge kinked or blocked A9 Condenser fan blocked or defective Blocked or defective A10 Evaporator fan blocked or defective Blocked or defective A11 Compressor Compressor overloaded A12 Condense...

Samsung DVM-S VRF Error Codes

  DVM Digital Variable Multi VRF Systems Error Codes Samsung DVM VRF Error Codes Error code related indoor unit: Error Codes Explanation E-101 Indoor unit communication error. Indoor unit can not receive any data from outdoor unit. E-102 Communication error between indoor unit and outdoor unit. Displayed in indoor unit. E-108 Error due to repeated address setting (When 2 or more devices has same address within the network) E-121 Error on indoor temperature sensor of indoor unit (Short or Open) E-122 Error on EVA IN sensor of indoor unit (Short or Open) E-123 Error on EVA OUT sensor of indoor unit (Short or Open) E-128 EVA IN temperature sensor of indoor unit is detached from EVA IN pipe E-129 EVA OUT temperature sensor of indoor unit is detached from EVA OUT pipe E-130 Heat exchanger in/out sensors of indoor unit are detached E-135 RPM feedback error of indoor unit's cleaning fan E-149 Error due to AHU master indoor unit sensor setting. E-151 Error due to opened EEV of indoor unit ...

Panasonic VRF AC Error Codes and Troubleshooting

  Indoor unit is detecting error signal from remote controller (and system controller). Panasonic Mini VRF AC Error Codes and Troubleshooting Error Codes Meaning E01 Error in receiving serial communication signal. E02 Error in transmitting serial communication signal. E03 Indoor unit is detecting error signal from remote controller. E04 Error in receiving serial communication signal. When turning on the power supply, the number of connected indoor units does not correspond to the number set. E06 Error of the outdoor unit in receiving serial communication signal from the indoor unit. E08 Indoor unit address setting is duplicated. E09 Remote controller address connector. E12 Starting auto address setting is prohibited. This alarm message shows that the auto address connector CN-A.ADD is shorted while other RC line is executing auto address operation. E15 Error in auto address setting. E16 Error in auto address setting. E20 No indoor unit is connected during auto address setting. E24 ...