McQuay Rooftop Package AC Error Codes

 When the system is on and an error occurs, the ON/OFF LED on the LCD panel will blink and an error code is shown. When the system is off and there is a thermistor error, the ON/OFF LED is off but the error code is still displayed. Each error code represents different message as below.

McQuay Rooftop Packaged AC Error Code
Error CodesPossible Fault
E01Require manual reset (possible causes)
E02Compressor 1 high temperature (overload)
E03Compressor 2 high temperature(overload)
E06Compressor 1 high pressure trip / contact open
E07Compressor 2 high pressure trip / contact open
E10Compressor 1 trip / low R-22 / outdoor abnormal
E11Compressor 2 trip / low R-22 / outdoor abnormal
E14Room sensor short
E15Room sensor open
E16Indoor coil sensor 1 short
E17Indoor coil sensor 2 short
E20Indoor coil sensor 1 open
E21Indoor coil sensor 2 open
E24Outdoor coil sensor 1 short
E25Outdoor coil sensor 2 short
E28 Outdoor coil sensor 1 open
E29Outdoor coil sensor 2 open
E32Compressor 1 de-ice
E33Compressor 2 de-ice

 

McQuay Rooftop Packaged Sequential Controller Functions

 

McQuay Rooftop Packaged AC Error Code
McQuay Rooftop Packaged AC Error Codes

Features

  • High Efficiency: The McQuay rooftop unit is supplied with high efficiency and reliable scroll compressor (except MRT 080/100/150/200 AR).
  • Package Unit: Dubbed the “Plug and Play” equivalent in the air-conditioning industry, the single unit configuration allows hassle free installation. No additional piping work is required as both the indoor and outdoor sides are pre-connected. Refrigerant is factory pre-charged to ensure clean and efficient operation.
  • Flexibility Of Air Supply: McQuay rooftop unit uses a belt driven fan such that the air volume and static required can be adjusted according to the requirement. This flexibility allows for wider application.
  • Flat Top Design: McQuay rooftop unit’s flat top design allows for maximum utilization of warehouse and container space.
  • Electrical Control Capability: All series are equipped with our Electronic Remote Controller (SLM and Sequential LCD). The Sequential LCD features 7 days programmable timer, compressor run/error status, cool/heat/fan/dry/auto modes, etc, while the SLM features a 15 hour delay timer, cool/heat/fan/dry/auto modes, etc. Part loading of system capacity is now possible with the use of our Sequential PAC (Package Air-Condition) control for multiple compressor McQuay rooftop units (M(4)RT150/200/250/300/360/420 A/AR).

McQuay Rooftop Packaged AC Manual PDF

Comments

Popular posts from this blog

Rittal Air Conditioner Error Codes

  System messages are shown on the display screen of the Comfort controller via the displays A1 to A20 and E0. Rittal Air Conditioner Error Codes Error Codes System message Possible cause A1 Enclosure door open Door open or door limit switch incorrectly positioned A2 Internal temperature of enclosure too high Cooling capacity inadequate/unit undersized. Error as a consequence of messages A03 to A17. A3 Filter monitoring Filter mat soiled A4 Ambient temperature too high/too low Ambient temperature outside of admissible operating range (+10°C to +60°C) A5 Icing hazard Operational display in case of icing hazard. A6 PSAH pressure-operated switch Ambient temperature too high A7 Evaporator coil Lack of coolant; sensor in front of or behind condenser defective. A8 Condensate warning Condensate discharge kinked or blocked A9 Condenser fan blocked or defective Blocked or defective A10 Evaporator fan blocked or defective Blocked or defective A11 Compressor Compressor overloaded A12 Condense...

Panasonic VRF AC Error Codes and Troubleshooting

  Indoor unit is detecting error signal from remote controller (and system controller). Panasonic Mini VRF AC Error Codes and Troubleshooting Error Codes Meaning E01 Error in receiving serial communication signal. E02 Error in transmitting serial communication signal. E03 Indoor unit is detecting error signal from remote controller. E04 Error in receiving serial communication signal. When turning on the power supply, the number of connected indoor units does not correspond to the number set. E06 Error of the outdoor unit in receiving serial communication signal from the indoor unit. E08 Indoor unit address setting is duplicated. E09 Remote controller address connector. E12 Starting auto address setting is prohibited. This alarm message shows that the auto address connector CN-A.ADD is shorted while other RC line is executing auto address operation. E15 Error in auto address setting. E16 Error in auto address setting. E20 No indoor unit is connected during auto address setting. E24 ...

Vestel AC Error Codes and Troubleshooting

  Error Messages   are displayed, respectively by first the   Er   icon and then the special code (01, 02, …, 20, etc.) of the failure. In that case, do nothing to the air conditioner and contact with the Authorised Service.   Er11   and   Er13   are not error messages. If you see these messages, apply the steps under the following protection messages section. Vestel AC Error Code and Troubleshooting Error Codes Cause dF The icing on the outdoor unit is being defrosted. After the defrosting operation is accomplished, your air conditioner will continue to operate in the heating mode, the product should not be turned off while this mode is enabled. RE Make the arc control for your electrical wiring, if the problem is not fixed call for the service. If the problem comes out very frequently, contact with the authorised service. Sr In case of certain failures, in order to not to spoil you comfort, your air conditioner continues to operate despite the f...