Error codesSolutions
EEIndoor machine EE fault
E1Indoor fan fault
E2Indoor fan zero-crossing detection abnormal
E3Indoor coil fault and sensor fault
E4Indoor ambient temperature sensor fault
E0Outdoor EE fault
E6Indoor and outdoor machine communication fault
E7Main board and driver board communication fault
F1Compressor starting abnormal (phase failure, reverse)
F2Compressor out-of-step fault
F3IPM module fault
F4Compressor shell roof fault / protection
F5Exhaust temperature sensor fault
F6Suction temperature sensor fault
F7Outdoor coil temperature sensor fault
F8Outdoor ambient temperature sensor fault
F9Outdoor DC fan fault

Marq By Flipkart Air Conditioner Maintenance

Marq By Flipkart Air Conditioner Maintenance
Marq By Flipkart Air Conditioner Maintenance

Periodic maintenance is essential for keeping your air conditioner efficient. Before carrying out any maintenance, disconnect the power supply by taking the plug out from the socket.

Indoor Unit

Anti-Dust Filters:

  1. Open the front panel following the direction of the arrow.
  2. Keeping the front panel raised with one hand, take out the air filter with the other hand.
  3. Clean the filter with water; if the filter is soiled with oil, it can be washed with warm water (not exceeding 45°C). Leave to dry in a cool and dry place.
  4. Keeping the front panel raised with one hand, insert the air filter with the other hand.
  5. Close.

The electrostatic and the deodorant filter (if installed) cannot be washed or regenerated and must be replaced with new filters after every 6 months.

Cleaning the Heat Exchanger:

  1. Open the front panel of the unit and life it till its greatest stroke and then unhooking it from the hinges to make the cleaning easier.
  2. Clean the indoor unit using a cloth with the water ( not higher than 40°C) and neutral soap. Never use aggressive solvents or detergents.
  3. lf the outdoor unit is clogged, remove the leaves and the waste and remove the dust with air jet or a bit of water.
Marq By Flipkart Air Conditioner Remote Control
Marq By Flipkart Air Conditioner Remote Control

Marq By Flipkart Air Conditioner Troubleshooting

MalfunctionPossible Causes
The appliance does not operatePower failure/plug pulled out.
Damaged indoor/outdoor unit fan motor.
Faulty compressor thermo-magnetic circuit breaker.
Faulty protective device or fuses.
Loose connections or plug pulled out.
It sometimes stops operating to protect the appliance.
Voltage higher or lower than the voltage range.
Active TIMER-ON function.
Damaged electronic control board.
Strange odourAir filter dirty.
Noise of running waterBack flow of liquid in the refrigerant circulation.
Afine mist comes from the air outletThis occurs when the air in the room becomes very cold, for example in the “COOLING” or “DEHUMIDIFYING/DRY” modes.
Astrange noise can be heardThis noise is made by the expansion or contraction of the front panel due to variations in temperature and does not indicate a problem.
Insufficient airflow, either hot or coldInappropriate temperature setting.
Air inlet or outlet of indoor or outdoor unit has been blocked.
Air filter is blocked.
Fan speed set at minimum.
Other sources of heat in the room.
No refrigerant.
The appliance does not respond to commandsRemote control is not near enough to indoor unit.
Battery in Remote controller may have been exhausted.
Obstacles between remote control and signal receiver in indoor unit.
The display is offActive LED function.
Power failure.

Switch off the air conditioner immediately and cut off the power supply in the event of:

  • Strange noises during operation.
  • Faulty electronic control board.
  • Faulty fuses or switches.
  • Spraying water or objects inside the appliance.
  • Overheated cables or plugs.
  • Very strong smells coming from the appliance.
Emergency Function,Auto-Restart Function
Emergency Function and Auto-Restart Function

Emergency Function: If the remote controller is lost or damaged, please use auxiliary button to tum on or tum off the air conditioner. The operation in details are as below: As shown in the fig. open panel, press aux. button to turn on or turn off the air conditioner. When the air conditioner is turned on, it will operate under auto mode. Warning: Use insulated object to press the aux. bution.

Auto-Restart Function: The appliance is equipped with Auto-Restart function by the manufacturer. In case of a power failure, the module memorizes the setting conditions before the power failure. When the power is restored, the unit restarts automatically with all the previous settings preserved by the memory function.

To deactivate the AUTO-RESTART function, proceed as follows:

  1. Switch the air conditioner off and plug it off.
  2. Press the emergency button and plug in the appliance.
  3. Long press the emergency button for more than 10 seconds until you hear four short beeps from the unit. The AUTO-RESTART function is deactivated.

To activate the AUTO – RESTART function, follow the same procedure until you hear three short beeps from the unit.

Marq By Flipkart Air Conditioner Manual PDF

Comments

Popular posts from this blog

Rittal Air Conditioner Error Codes

  System messages are shown on the display screen of the Comfort controller via the displays A1 to A20 and E0. Rittal Air Conditioner Error Codes Error Codes System message Possible cause A1 Enclosure door open Door open or door limit switch incorrectly positioned A2 Internal temperature of enclosure too high Cooling capacity inadequate/unit undersized. Error as a consequence of messages A03 to A17. A3 Filter monitoring Filter mat soiled A4 Ambient temperature too high/too low Ambient temperature outside of admissible operating range (+10°C to +60°C) A5 Icing hazard Operational display in case of icing hazard. A6 PSAH pressure-operated switch Ambient temperature too high A7 Evaporator coil Lack of coolant; sensor in front of or behind condenser defective. A8 Condensate warning Condensate discharge kinked or blocked A9 Condenser fan blocked or defective Blocked or defective A10 Evaporator fan blocked or defective Blocked or defective A11 Compressor Compressor overloaded A12 Condense...

Samsung DVM-S VRF Error Codes

  DVM Digital Variable Multi VRF Systems Error Codes Samsung DVM VRF Error Codes Error code related indoor unit: Error Codes Explanation E-101 Indoor unit communication error. Indoor unit can not receive any data from outdoor unit. E-102 Communication error between indoor unit and outdoor unit. Displayed in indoor unit. E-108 Error due to repeated address setting (When 2 or more devices has same address within the network) E-121 Error on indoor temperature sensor of indoor unit (Short or Open) E-122 Error on EVA IN sensor of indoor unit (Short or Open) E-123 Error on EVA OUT sensor of indoor unit (Short or Open) E-128 EVA IN temperature sensor of indoor unit is detached from EVA IN pipe E-129 EVA OUT temperature sensor of indoor unit is detached from EVA OUT pipe E-130 Heat exchanger in/out sensors of indoor unit are detached E-135 RPM feedback error of indoor unit's cleaning fan E-149 Error due to AHU master indoor unit sensor setting. E-151 Error due to opened EEV of indoor unit ...

Panasonic VRF AC Error Codes and Troubleshooting

  Indoor unit is detecting error signal from remote controller (and system controller). Panasonic Mini VRF AC Error Codes and Troubleshooting Error Codes Meaning E01 Error in receiving serial communication signal. E02 Error in transmitting serial communication signal. E03 Indoor unit is detecting error signal from remote controller. E04 Error in receiving serial communication signal. When turning on the power supply, the number of connected indoor units does not correspond to the number set. E06 Error of the outdoor unit in receiving serial communication signal from the indoor unit. E08 Indoor unit address setting is duplicated. E09 Remote controller address connector. E12 Starting auto address setting is prohibited. This alarm message shows that the auto address connector CN-A.ADD is shorted while other RC line is executing auto address operation. E15 Error in auto address setting. E16 Error in auto address setting. E20 No indoor unit is connected during auto address setting. E24 ...