 If the system does not properly operate except the above mentioned cases or the above mentioned malfunctions is evident, investigate the system according to the following procedures.

Lloyd Air Conditioner Error Codes
Lloyd Air Conditioner Error Codes

Troubles and Causes of Remote Controller;

Before asking for serving or repairing, check the following points.

Error CodesMalfunction
E2Room temperature sensor checking channel is abnormal. LED 2 Timer: Flashing
E3Pipe temperature sensor checking channel is abnormal. LED 1 Operation: Flashing
E4Outdoor pipe TEMP. sensor checking is abnormal. LED 3 Def.Fan: Flashing
E6Outdoor malfunction. LED 1, LED 2, LED 3, LED 4 : Flashing
E7EEPROM malfunction. LED 1, LED 2 : Flashing
E8Water-level alarm malfunction. LED 4 Alarm: Flashing
CLCL is not actually a fault code. it is an indication that the child lock is activated.
DFThe df fault code signals a defrost mode issue.
H3The h3 fault code indicates a compressor overload protection issue.
P3Lack of gas in the system or the pcb is miscalculating the gas pressure.
P4When the indoor unit displays an P4 error on temperature indicator, it means there is an inverter compressor drive error.
Four-way Cassette Type Air Conditioner E2-E3-E4-E6-E7-E8
Four-way Cassette Type Air Conditioner E2-E3-E4-E6-E7-E8

Troubles and causes of air conditioner

If one of the following malfunctions occur, stop operation, shut off the power, and contact with your dealer.

    • The operation lamp is flashing rapidly (5Hz). This lamp is still flashing rapidly after turn off the power and turn on again.
    • Remote controller receives malfunction or the button does not work well.
    • A safety device such as a fuse, a breaker frequently actuates.
    • Obstacles and water enter the unit.
    • Water leaks from indoor unit.
    • Other malfunctions.

Troubleshooting

Symptoms: Unit does not start

Causes:

      1. Power failure.
      2. Power switch is off.
      3. Fuse of power switch may have burned.
      4. Batteries of remote controller exhausted or other problem of controller.

Solution:

      1. Wait for the comeback of power.
      2. Switch on the power.
      3. Replace the fuse.
      4. Replace the batteries or check the controller.

Symptoms: Units start or stop frequently

Causes:

      1. Refrigerant is too little or too much.
      2. Air or no concreting gas in the refrigerating circuit.
      3. Compressor is malfunction.
      4. Voltage is too high or too low.
      5. System circuit is blocked.

Solution:

      1. Check leakage, and rightly recharge refrigerant.
      2. Vacuum and recharge refrigerant.
      3. Maintenance or change compressor.
      4. Install manostat.
      5. Find reasons and solution.

Symptoms: Low cooling effect

Causes:

      1. Outdoor unit and indoor unit heat exchanger is dirty.
      2. The air filter is dirty.
      3. Inlet/outlet of indoor/outdoor units is blocked.
      4. Doors and windows are open
      5. Sunlight directly shine.
      6. Too much heat resource.
      7. Outdoor temp. is too high.
      8. Leakage of refrigerant or lack of refrigerant.

Solution:

      1. Clean the heat exchanger.
      2. Clean the air filter.
      3. Eliminate all dirties and make air smooth.
      4. Close doors and windows.
      5. Make curtains in order to shelter from sunshine.
      6. Reduce heat source.
      7. AC cooling capacity reduces (normal).
      8. Check leakage and rightly recharge refrigerant.

Symptoms: Low heating effect

Causes:

      1. Outdoor temperature is lower than 7 C .
      2. Doors and windows not completely closed.
      3. Leakage of refrigerant or lack of refrigerant.

Solution:

      1. Use heating device.
      2. Close doors and windows.
      3. Check leakage and rightly recharge refrigerant.

Symptoms: The fan speed can not be changed.

Causes:

      1. Check whether the MODE indicated on the display is “AUTO”
      2. Check whether the MODE indicated on the display is “DRY”

Solution:

      1. When the automatic mode is selected, the air conditioner will automatically change the fan speed.
      2. When dry operation is selected, the air conditioner automatically change the fan speed. The fan speed can be selected during “COOL” , “FAN ONLY”, and “HEAT”.

 

Lloyd-Air-Conditioner-Error-Code
Lloyd Air Conditioner Error Code
Lloyd-Air-Conditioner-Error-CodeS
Lloyd Air Conditioner Error Codes

Symptoms: The remote controller signal is not transmitted even when the ON/OFF button is pushed.

Causes: Check whether the batteries in the remote controller are exhausted.

Solution: The power supply is off.

Symptoms: The TEMP. indicator does not come on.

Causes: Check whether the MODE indicated on the display is FAN ONLY.

Solution: The temperature cannot be set during FAN mode.

Symptoms: The indication on the display disappears after a lapse of time.

Causes: Check whether the timer operation has come to an end when the TIMER OFF is indicated on the display.

Solution: The air conditioner operation will stop up to the set time.

Symptoms: The TIMER ON indicator goes off after a lapse of certain time.

Causes: Check whether the timer operation is started when the TIMER ON is indicated on the display.

Solution: Up to the set time, the air conditioner will automatically start and the appropriate indicator will go off.

Symptoms: No receiving tone sounds from the indoor unit even when the ON/OFF button is pressed.

Causes: Check whether the signal transmitter of the remote controller is properly directed to the infrared signal receiver of the indoor unit when the ON/OFF button is pressed.

Solution: Directly transmit the signal transmitter of the remote controller to the infrared signal receiver of the indoor unit, and then repeatly push the ON/OFF button twice.

 Lloyd Air Conditioner  Manual PDF

Comments

Popular posts from this blog

Rittal Air Conditioner Error Codes

  System messages are shown on the display screen of the Comfort controller via the displays A1 to A20 and E0. Rittal Air Conditioner Error Codes Error Codes System message Possible cause A1 Enclosure door open Door open or door limit switch incorrectly positioned A2 Internal temperature of enclosure too high Cooling capacity inadequate/unit undersized. Error as a consequence of messages A03 to A17. A3 Filter monitoring Filter mat soiled A4 Ambient temperature too high/too low Ambient temperature outside of admissible operating range (+10°C to +60°C) A5 Icing hazard Operational display in case of icing hazard. A6 PSAH pressure-operated switch Ambient temperature too high A7 Evaporator coil Lack of coolant; sensor in front of or behind condenser defective. A8 Condensate warning Condensate discharge kinked or blocked A9 Condenser fan blocked or defective Blocked or defective A10 Evaporator fan blocked or defective Blocked or defective A11 Compressor Compressor overloaded A12 Condense...

Samsung DVM-S VRF Error Codes

  DVM Digital Variable Multi VRF Systems Error Codes Samsung DVM VRF Error Codes Error code related indoor unit: Error Codes Explanation E-101 Indoor unit communication error. Indoor unit can not receive any data from outdoor unit. E-102 Communication error between indoor unit and outdoor unit. Displayed in indoor unit. E-108 Error due to repeated address setting (When 2 or more devices has same address within the network) E-121 Error on indoor temperature sensor of indoor unit (Short or Open) E-122 Error on EVA IN sensor of indoor unit (Short or Open) E-123 Error on EVA OUT sensor of indoor unit (Short or Open) E-128 EVA IN temperature sensor of indoor unit is detached from EVA IN pipe E-129 EVA OUT temperature sensor of indoor unit is detached from EVA OUT pipe E-130 Heat exchanger in/out sensors of indoor unit are detached E-135 RPM feedback error of indoor unit's cleaning fan E-149 Error due to AHU master indoor unit sensor setting. E-151 Error due to opened EEV of indoor unit ...

Panasonic VRF AC Error Codes and Troubleshooting

  Indoor unit is detecting error signal from remote controller (and system controller). Panasonic Mini VRF AC Error Codes and Troubleshooting Error Codes Meaning E01 Error in receiving serial communication signal. E02 Error in transmitting serial communication signal. E03 Indoor unit is detecting error signal from remote controller. E04 Error in receiving serial communication signal. When turning on the power supply, the number of connected indoor units does not correspond to the number set. E06 Error of the outdoor unit in receiving serial communication signal from the indoor unit. E08 Indoor unit address setting is duplicated. E09 Remote controller address connector. E12 Starting auto address setting is prohibited. This alarm message shows that the auto address connector CN-A.ADD is shorted while other RC line is executing auto address operation. E15 Error in auto address setting. E16 Error in auto address setting. E20 No indoor unit is connected during auto address setting. E24 ...