Lennox Rooftop-Gas Furnace Error Codes

 Climatic 50 Roof-Top, Aircoolair & Compactair Version 24

Lennox Rooftop-Gas Furnace Error Codes
Lennox Rooftop-Gas Furnace Error Codes
Error CodesProblem
001Airflow
004Filters, Clogged up
005Filters, Missing
006Recovery Module , Filters, Clogged up
011Electric heating elements
012High Temperature, Blowing
013Low Temperature, Ambient
014Gas burner, 1
015Gas burner, 2
022Low Temperature, Blowing
023High Temperature, Ambient
031Humidifier
032Low Humidity, Ambient
033High Humidity, Ambient
041Pump
051Recovery Module, Motor failure
052Recovery Module, Wheel failure
070Clock card
071BE50, 1
072BE50, 2
081Temperature sensor, Ambient
082Humidity sensor, Ambient
083Temperature probe, Outside
084Humidity sensor, Outside
085Temperature probe, Blower
086Circuit 1, Temperature sensor, Water condenser Outlet
087Circuit 2, Temperature sensor, Water condenser Outlet
088Temperature sensor, return or Mixing air
091Blower
092Circuit 1, Condenser fan
093Circuit 2, Condenser fan
094Circuit 3, Condenser fan
095Circuit 4, Condenser fan
096Low temperature, Water Condenser
097High temperature, Water Condenser
098Flow rate, water condenser
099Smoke detector
111Circuit 1, Probe or Sensor
115Circuit 1, High pressure or electrical protection
117Circuit 1, Low pressure
118Circuit 1, Risk of Frosting
121Circuit 2, Probe or Sensor
125Circuit 2, High pressure or electrical protection
127Circuit 2, Low pressure
128Circuit 2, Risk of Frosting
131Circuit 3, Probe or Sensor
135Circuit 3, High pressure or electrical protection
137Circuit 3, Low pressure
141Circuit 4, Probe or Sensor
145Circuit 4, High pressure or electrical protection
147Circuit 4, Low pressure

Lennox Gas Furnace Error Codes

Lennox Gas Furnace Error Codes
Lennox Gas Furnace Error Codes

EL180DFE series units are mid-efficiency gas furnaces used for downflow applications only, manufactured with Lennox Duralok heat exchangers formed of aluminized steel. EL180DFE units are available in heating capacities of 44,000 to 110,000 Btuh and cooling applications 1.5 to 5 tons. Refer to Engineering Handbook for proper sizing.

The integrated control is equipped with an LED light for troubleshooting

Off -No power to control or board fault detected

On- Board fault detected,

Heartbeat1- Control powered – displayed during all modes of operation if no errors are detected

1 Reverse Line Voltage Polarity

2 Improper Earth Ground

3 Burner failed to light, or lost flame during heat demand

4 Low Flame Signal – check flame sensor

5 Watchguard – burner failed to light, exceeded maximum number of retries or recycles.

6 Not Used

7 Primary or Secondary Limit Open or Watchguard Mode  – Limit Switch Open longer than 3 minutes.

8 Rollout Switch Open

9 Pressure Switch failed to close or opened during heat demand

10 Watchguard – Pressure Switch opened 5 times during one heat demand

11 Pressure Switch stuck closed prior to activation of combustion air inducer

12 Flame Sensed without gas valve energized

13 Low Line Voltage

Notes:

Note 1

A ”Heartbeat” is indicated by a ”Slow Flash” – 1 sec on 1 sec off, repeating

Note 2

Error codes are indicated by a ”Rapid Flash” – the LED flashes X times at 1/2 sec on 1/2 sec off, remains off for 3 sec, then repeats

Note 3
Last 10 error codes are stored in memory including when power is shut off to the unit. – To recall, press and release button, most recent will be displayed first, LED off for 3 sec, then next error code is displayed, etc. To clear error codes, depress and hold button longer than 5 seconds.

Lennox AC Error Codes and Troubleshooting

INSTALLATION OPERATING & MAINTENANCE MANUAL:

Lennox Rooftop Service Manual

Comments

Popular posts from this blog

Rittal Air Conditioner Error Codes

  System messages are shown on the display screen of the Comfort controller via the displays A1 to A20 and E0. Rittal Air Conditioner Error Codes Error Codes System message Possible cause A1 Enclosure door open Door open or door limit switch incorrectly positioned A2 Internal temperature of enclosure too high Cooling capacity inadequate/unit undersized. Error as a consequence of messages A03 to A17. A3 Filter monitoring Filter mat soiled A4 Ambient temperature too high/too low Ambient temperature outside of admissible operating range (+10°C to +60°C) A5 Icing hazard Operational display in case of icing hazard. A6 PSAH pressure-operated switch Ambient temperature too high A7 Evaporator coil Lack of coolant; sensor in front of or behind condenser defective. A8 Condensate warning Condensate discharge kinked or blocked A9 Condenser fan blocked or defective Blocked or defective A10 Evaporator fan blocked or defective Blocked or defective A11 Compressor Compressor overloaded A12 Condense...

Samsung DVM-S VRF Error Codes

  DVM Digital Variable Multi VRF Systems Error Codes Samsung DVM VRF Error Codes Error code related indoor unit: Error Codes Explanation E-101 Indoor unit communication error. Indoor unit can not receive any data from outdoor unit. E-102 Communication error between indoor unit and outdoor unit. Displayed in indoor unit. E-108 Error due to repeated address setting (When 2 or more devices has same address within the network) E-121 Error on indoor temperature sensor of indoor unit (Short or Open) E-122 Error on EVA IN sensor of indoor unit (Short or Open) E-123 Error on EVA OUT sensor of indoor unit (Short or Open) E-128 EVA IN temperature sensor of indoor unit is detached from EVA IN pipe E-129 EVA OUT temperature sensor of indoor unit is detached from EVA OUT pipe E-130 Heat exchanger in/out sensors of indoor unit are detached E-135 RPM feedback error of indoor unit's cleaning fan E-149 Error due to AHU master indoor unit sensor setting. E-151 Error due to opened EEV of indoor unit ...

Panasonic VRF AC Error Codes and Troubleshooting

  Indoor unit is detecting error signal from remote controller (and system controller). Panasonic Mini VRF AC Error Codes and Troubleshooting Error Codes Meaning E01 Error in receiving serial communication signal. E02 Error in transmitting serial communication signal. E03 Indoor unit is detecting error signal from remote controller. E04 Error in receiving serial communication signal. When turning on the power supply, the number of connected indoor units does not correspond to the number set. E06 Error of the outdoor unit in receiving serial communication signal from the indoor unit. E08 Indoor unit address setting is duplicated. E09 Remote controller address connector. E12 Starting auto address setting is prohibited. This alarm message shows that the auto address connector CN-A.ADD is shorted while other RC line is executing auto address operation. E15 Error in auto address setting. E16 Error in auto address setting. E20 No indoor unit is connected during auto address setting. E24 ...