Lennox Rooftop-Gas Furnace Error Codes

 Climatic 50 Roof-Top, Aircoolair & Compactair Version 24

Lennox Rooftop-Gas Furnace Error Codes
Lennox Rooftop-Gas Furnace Error Codes
Error CodesProblem
001Airflow
004Filters, Clogged up
005Filters, Missing
006Recovery Module , Filters, Clogged up
011Electric heating elements
012High Temperature, Blowing
013Low Temperature, Ambient
014Gas burner, 1
015Gas burner, 2
022Low Temperature, Blowing
023High Temperature, Ambient
031Humidifier
032Low Humidity, Ambient
033High Humidity, Ambient
041Pump
051Recovery Module, Motor failure
052Recovery Module, Wheel failure
070Clock card
071BE50, 1
072BE50, 2
081Temperature sensor, Ambient
082Humidity sensor, Ambient
083Temperature probe, Outside
084Humidity sensor, Outside
085Temperature probe, Blower
086Circuit 1, Temperature sensor, Water condenser Outlet
087Circuit 2, Temperature sensor, Water condenser Outlet
088Temperature sensor, return or Mixing air
091Blower
092Circuit 1, Condenser fan
093Circuit 2, Condenser fan
094Circuit 3, Condenser fan
095Circuit 4, Condenser fan
096Low temperature, Water Condenser
097High temperature, Water Condenser
098Flow rate, water condenser
099Smoke detector
111Circuit 1, Probe or Sensor
115Circuit 1, High pressure or electrical protection
117Circuit 1, Low pressure
118Circuit 1, Risk of Frosting
121Circuit 2, Probe or Sensor
125Circuit 2, High pressure or electrical protection
127Circuit 2, Low pressure
128Circuit 2, Risk of Frosting
131Circuit 3, Probe or Sensor
135Circuit 3, High pressure or electrical protection
137Circuit 3, Low pressure
141Circuit 4, Probe or Sensor
145Circuit 4, High pressure or electrical protection
147Circuit 4, Low pressure

Lennox Gas Furnace Error Codes

Lennox Gas Furnace Error Codes
Lennox Gas Furnace Error Codes

EL180DFE series units are mid-efficiency gas furnaces used for downflow applications only, manufactured with Lennox Duralok heat exchangers formed of aluminized steel. EL180DFE units are available in heating capacities of 44,000 to 110,000 Btuh and cooling applications 1.5 to 5 tons. Refer to Engineering Handbook for proper sizing.

The integrated control is equipped with an LED light for troubleshooting

Off -No power to control or board fault detected

On- Board fault detected,

Heartbeat1- Control powered – displayed during all modes of operation if no errors are detected

1 Reverse Line Voltage Polarity

2 Improper Earth Ground

3 Burner failed to light, or lost flame during heat demand

4 Low Flame Signal – check flame sensor

5 Watchguard – burner failed to light, exceeded maximum number of retries or recycles.

6 Not Used

7 Primary or Secondary Limit Open or Watchguard Mode  – Limit Switch Open longer than 3 minutes.

8 Rollout Switch Open

9 Pressure Switch failed to close or opened during heat demand

10 Watchguard – Pressure Switch opened 5 times during one heat demand

11 Pressure Switch stuck closed prior to activation of combustion air inducer

12 Flame Sensed without gas valve energized

13 Low Line Voltage

Notes:

Note 1

A ”Heartbeat” is indicated by a ”Slow Flash” – 1 sec on 1 sec off, repeating

Note 2

Error codes are indicated by a ”Rapid Flash” – the LED flashes X times at 1/2 sec on 1/2 sec off, remains off for 3 sec, then repeats

Note 3
Last 10 error codes are stored in memory including when power is shut off to the unit. – To recall, press and release button, most recent will be displayed first, LED off for 3 sec, then next error code is displayed, etc. To clear error codes, depress and hold button longer than 5 seconds.

Lennox AC Error Codes and Troubleshooting

INSTALLATION OPERATING & MAINTENANCE MANUAL:

Lennox Rooftop Service Manual

Comments

Popular posts from this blog

AUX Air Con Error Codes

Aux Air Conditioner Troubleshooting November 3, 2018 at 9:18 pm If the following phenomena are found, the problem is not from the  air-conditioner itself. Problems The motor is heard operating but the air-conditioner dose not work when the indoor unit is powered on Causes Since the air-conditioner is powered on, it will come to working condition as long as you press the ON/OFF button of the remote control and the Signal is well received. Problems The compressor stops running but the indoor fan motor keeps working when it is at cooling mode with the indoor temperature higher than set temperature. Causes If you turn off the air-conditioner and restart it immediately, it will return to normal in 3 minutes, after that, the air-conditioner will automatically adjust the indoor fan speed to what you set. Problems The compressor works discontinuously at dehumidifying mode. Causes The air-conditioner will automatically control the working of the compressor according to the insi

Acson AC Error Codes and Troubleshooting

Acson AC Error Codes and Troubleshooting   The code indication changes as shown below, and notifies with a long beep. Wall Mounted AC Inverter Unit Error Codes Operation / Faulty Indication E1 Room air sensor contact loose / short. Check room sensor connection / change room sensor E2 Indoor coil sensor contact open. Check indoor coil sensor connection / change indoor coil sensor E3 Outdoor coil sensor contact open. Check outdoor coil sensor connection / change outdoor coil sensor E4 Compressor overload protection / Indoor / Outdoor coil sensor short. If running ampere highly increase, change the compressor. If not, replace the coil sensor E5 Gas leak. Check for leakage & repair / Top up refrigerant E6 Pump fault. Clear the clogging at drain pipe. If pump is not working, change the pump E7 Outdoor coil sensor exist (MS model). Remove outdoor coil sensor E8 Hardware error (tact switch pin short). Check for the tact switch pin condition E9 No Feedback from indoor fan. Check indoor fan

Samsung DVM-S VRF Error Codes

  DVM Digital Variable Multi VRF Systems Error Codes Samsung DVM VRF Error Codes Error code related indoor unit: Error Codes Explanation E-101 Indoor unit communication error. Indoor unit can not receive any data from outdoor unit. E-102 Communication error between indoor unit and outdoor unit. Displayed in indoor unit. E-108 Error due to repeated address setting (When 2 or more devices has same address within the network) E-121 Error on indoor temperature sensor of indoor unit (Short or Open) E-122 Error on EVA IN sensor of indoor unit (Short or Open) E-123 Error on EVA OUT sensor of indoor unit (Short or Open) E-128 EVA IN temperature sensor of indoor unit is detached from EVA IN pipe E-129 EVA OUT temperature sensor of indoor unit is detached from EVA OUT pipe E-130 Heat exchanger in/out sensors of indoor unit are detached E-135 RPM feedback error of indoor unit's cleaning fan E-149 Error due to AHU master indoor unit sensor setting. E-151 Error due to opened EEV of indoor unit