Lennox AC Error Codes and Troubleshooting

 This manual is applicable only to the following models.

Lennox Air Conditioner Inverter Split Type Error Codes;

Lennox AC Error Codes and Troubleshooting
Lennox AC Error Codes and Troubleshooting

LNIV2610 LNIV3510 LNIV5010 LNIV6510

Indoor Unit Error Display:

Error CodesCause
E0EEPROM parameter error
E1Indoor/outdoor units communication protection
E2Zero-crossing signal error
E3Indoor fan speed out of control
E5Open or short circuit of outdoor temperature sensor or outdoor unit EEPROM parameter error
E6Open or short circuit of room or evaporator temperature sensor
E7Outdoor fan speed out of control
P0IBM malfunction or IGBT over-strong current protection
P1Over voltage or too low voltage protection
P2Temperature protection of compressor top
P4Inverter compressor drive error

Lennox Split AC Error Codes

If there is an error occurring during the operation of the system, the error code will be displayed on the LCD, as show in Fig.5.1. If multi errors occur at the same time, their codes will be displayed circularly.

Lennox Split AC Error Codes
Lennox Split AC Error Codes

Note: In event of any error, please turn off the unit and contact the professionally skilled personnel.

Meaning of Each Error

Error CodesMeaning
F1Return air temperature sensor open/ short circuited
P6Drive board communication error
F2Evaporator temperature sensor open/ short circuited
H3Compressor overheating protection
b5Indoor unit liquid valve temperature sensor open/short circuited
LPIndoor and outdoor units unmatched
b7Indoor gas valve temperature sensor open/ short circuited
dnCommunication line misconnected or expansion valve error
P7IPM temperature sensor open/short circuited
E7Running mode conflict
F3Outdoor ambient temperature sensor open/ short circuited
FoPump-down
F4Outdoor unit condenser mid-tube temperature sensor open/short circuited
C5Jumper error
F5Discharge temperature sensor open/ short circuited
H1Forced defrosting
E6Indoor and outdoor communication error
LcCompressor startup failure
PLDC bus under-voltage protection......
E4High discharge temperature protection
PHDC bus over-voltage protection
E8Overload protection
U1Compressor phase current sensing circuit error
E5Whole unit over-current protection
HECompressor demagnetization protection
P5Over phase current protection
HcPFC protection
H7Compressor desynchronizing
P8IPM Temperature Protection
H5IPM Current protection
L9Over-power protection
LdCompressor phase loss/reversal protection
F0System charge shortage or blockage protection
F8Frequency restricted/reduced with whole unit current protection
PUCapacitor charging error
IPMFrequency restricted/reduced with
EnCurrent protection
E1High pressure protection
F9Frequency restricted/reduced with high discharge temperature
E3Low pressure protection
FHFrequency restricted/reduced with antifreezing protection
LECompressor stalling
F6Frequency restricted/reduced with overload protection
LFOver-speeding
EUFrequency restricted/reduced with IPM temperature protection
PFDrive board temperature sensor error
E9Indoor unit full water error
P9AC contactor protection
E2Anti-freezing protection
PETemperature drift protection
PPAC input voltage abnormal
PdSensor connection protection
U5Whole unit current sensing circuit error
U3DC bus voltage drop error
U74-way valve reversing error
L3Outdoor fan 1 error protection
H6Motor stalling
LAOutdoor fan 2 error protection
U8PG motor zero-crossing protection
Lennox AC Remote Control
Lennox AC Remote Control

Lennox Air Conditioner Mini Split Error Codes

Lennox Air Conditioner Mini Split Error Codes
Lennox Air Conditioner Mini Split Error Codes

Indoor and Outdoor Error Codes

 

INDOOR UNIT DISPLAY CODES (ALL SYSTEMS) 2
INDOOR UNIT DISPLAY CODES (ALL SYSTEMS) 2
INDOOR UNIT DISPLAY CODES (ALL SYSTEMS) 6
INDOOR UNIT DISPLAY CODES (ALL SYSTEMS) 6

 

INDOOR UNIT DISPLAY CODES (ALL SYSTEMS)
INDOOR UNIT DISPLAY CODES (ALL SYSTEMS)

 

INDOOR UNIT DISPLAY CODES (ALL SYSTEMS)3
INDOOR UNIT DISPLAY CODES (ALL SYSTEMS)3
INDOOR UNIT DISPLAY CODES (ALL SYSTEMS)4
INDOOR UNIT DISPLAY CODES (ALL SYSTEMS)4

 

Lennox AC Troubleshooting

Please check below items before asking for maintenance.

Phenomenon: Indoor unit can’t receive remote controller’s signal or remote controller has no action.

Check items:

  1. Whether remote controller is within the signal receiving range?
  2. Whether there are obstacles?
  3. Whether remote controller is pointing at the receiving window?
  4. Is sensitivity of remote controller low; fuzzy display and no display?
  5. No display when operating remote controller?
  6. Fluorescent lamp in room?

Solution:

  1. Signal receiving range is 8m.
  2. Remove obstacles.
  3. Select proper angle and point the remote controller at the receiving window on indoor unit.
  4. Check the batteries. If the power of batteries is too low, please replace them.
  5. Check whether remote controller appears to be damaged. If yes, replace it.
  6. Take the remote controller close to indoor unit.

Phenomenon: No air emitted from indoor unit

Check items:

  1. Air inlet or air outlet of indoor unit is blocked?
  2. Under heating mode, indoor temperature is reached to set temperature?
  3. Heating mode is turned on just now?

Solution:

  1. Eliminate obstacles.
  2. After reaching to set temperature, indoor unit will stop blowing out air.
  3. In order to prevent blowing out cold air, indoor unit will be started after delaying for several minutes, which is a normal phenomenon.

Phenomenon: Air conditioner can’t operate

Check items:

  1. Power failure?
  2. Is plug loose?
  3. Air switch trips off or fuse is burnt out?
  4. Wiring has malfunction?
  5. Unit has restarted immediately after stopping operation?
  6. Whether the function setting for remote controller is correct?

Solution:

  1. Wait until power recovery.
  2. Reinsert the plug.
  3. Ask professional to replace air switch or fuse.
  4. Ask professional to replace it.
  5. Wait for 3min, and then turn on the unit again.
  6. Reset the function.

Phenomenon: Mist is emitted from indoor unit’s air outlet

Check items: Indoor temperature and humidity is high?

Solution: Because indoor air is cooled\rapidly. After a while, indoor temperature and humidity will be decrease and mist will disappear.

Phenomenon: Cooling ( heating) effect is not good

Check items:

  1. Voltage is too low?
  2. Filter is dirty?
  3. Set temperature is in proper range?
  4. Door and window are open?

Solution:

  1. Wait until the voltage resumes normal.
  2. Clean the filter.
  3. Adjust temperature to proper range.
  4. Close door and window.

Phenomenon: Outdoor unit has vapor

Check items: Heating mode is turned on?

Solution: During defrosting under heating mode, it may generate vapor, which is a normal phenomenon.

Phenomenon: ”Water flowing” noise

Check items: Air conditioner is turned on or turned offjust now?

Solution: The noise is the sound of \refrigerant flowing inside the unit, which is a normal phenomenon.

Phenomenon: Cracking noise

Check items: Air conditioner is turned on or turned offjust now?

Solution: This is the sound of frictioh caused by expansion and/or contraction of panel or other parts clue to the change of temperature.

Lennox Air Conditioner Manual PDF

Comments

Popular posts from this blog

Rittal Air Conditioner Error Codes

  System messages are shown on the display screen of the Comfort controller via the displays A1 to A20 and E0. Rittal Air Conditioner Error Codes Error Codes System message Possible cause A1 Enclosure door open Door open or door limit switch incorrectly positioned A2 Internal temperature of enclosure too high Cooling capacity inadequate/unit undersized. Error as a consequence of messages A03 to A17. A3 Filter monitoring Filter mat soiled A4 Ambient temperature too high/too low Ambient temperature outside of admissible operating range (+10°C to +60°C) A5 Icing hazard Operational display in case of icing hazard. A6 PSAH pressure-operated switch Ambient temperature too high A7 Evaporator coil Lack of coolant; sensor in front of or behind condenser defective. A8 Condensate warning Condensate discharge kinked or blocked A9 Condenser fan blocked or defective Blocked or defective A10 Evaporator fan blocked or defective Blocked or defective A11 Compressor Compressor overloaded A12 Condense...

Panasonic VRF AC Error Codes and Troubleshooting

  Indoor unit is detecting error signal from remote controller (and system controller). Panasonic Mini VRF AC Error Codes and Troubleshooting Error Codes Meaning E01 Error in receiving serial communication signal. E02 Error in transmitting serial communication signal. E03 Indoor unit is detecting error signal from remote controller. E04 Error in receiving serial communication signal. When turning on the power supply, the number of connected indoor units does not correspond to the number set. E06 Error of the outdoor unit in receiving serial communication signal from the indoor unit. E08 Indoor unit address setting is duplicated. E09 Remote controller address connector. E12 Starting auto address setting is prohibited. This alarm message shows that the auto address connector CN-A.ADD is shorted while other RC line is executing auto address operation. E15 Error in auto address setting. E16 Error in auto address setting. E20 No indoor unit is connected during auto address setting. E24 ...

Vestel AC Error Codes and Troubleshooting

  Error Messages   are displayed, respectively by first the   Er   icon and then the special code (01, 02, …, 20, etc.) of the failure. In that case, do nothing to the air conditioner and contact with the Authorised Service.   Er11   and   Er13   are not error messages. If you see these messages, apply the steps under the following protection messages section. Vestel AC Error Code and Troubleshooting Error Codes Cause dF The icing on the outdoor unit is being defrosted. After the defrosting operation is accomplished, your air conditioner will continue to operate in the heating mode, the product should not be turned off while this mode is enabled. RE Make the arc control for your electrical wiring, if the problem is not fixed call for the service. If the problem comes out very frequently, contact with the authorised service. Sr In case of certain failures, in order to not to spoil you comfort, your air conditioner continues to operate despite the f...