Klimaire Air Conditioner Error Codes

 Models: KSIM20912-H216, KSIM30912-H216, KSIM40912-H216

Klimaire Air Conditioner Error Codes
Error CodesProblem
Troubleshooting for indoor unit
E0EEPROM error
E1Communication error between indoor and outdoor unit
E2Zero-crossing examination error
E3Fan speed beyond control
E5Outdoor units temp. sensor or connector of temp. sensor is defective
E6Indoor units temp. sensor or connector of temp. sensor is defective
P0Inverter module protection
P1Outdoor voltage too low protection
P2Compressor discharge temp. protection
P3Outdoor temp. too low protection
P4Compressor driving protection
P5Outdoor temp. too low protection
Troubleshooting for outdoor unit
E1No 1 Indoor units pipe temp. sensor or connector of pipe temp. sensor is defective
E2No 2 Indoor units pipe temp. sensor or connector of pipe temp. sensor is defective
E3No 3 Indoor units pipe temp. sensor or connector of pipe temp. sensor is defective
E6No 4 Indoor units pipe temp. sensor or connector of pipe temp. sensor is defective
E4Outdoor temp. sensor or connector of temp. sensor is defective
E5Compressor volt protection
E7Communication error between outdoor IC and DSP
P0Compressor discharge temp. protection
P1High pressure protection (just for 36K 1x4 units.)
P2Low pressure protection (just for 36K 1x4 units.)
P3Compressor current protection
P4Inverter module protection
P5Outdoor temp. too low protection
P6 Condenser high-temperature protection
P7Compressor driving protection
PF PFC protection.

Diagnosis and Solution:

EEPROM parameter error diagnosis and solution (E0/F4):

Malfunction decision conditions: Indoor or outdoor PCB main chip does not receive feedback from EEPROM chip.

Supposed causes: Installation mistake. PCB faulty .

Indoor / outdoor unit’s communication diagnosis and solution (E1):

Malfunction decision conditions: Indoor unit does not receive the feedback from outdoor unit during 110 seconds and this condition happens four times continuously.

Supposed causes: Wiring mistake. Indoor or outdoor PCB faulty.

Zero crossing detection error diagnosis and solution (E2)

Malfunction decision conditions: When PCB does not receive zero crossing signal feedback for 4 minutes or the zero crossing signal time interval is abnormal.

Supposed causes: Connection mistake. PCB faulty.

Fan speed has been out of control diagnosis and solution (E3)

Malfunction decision conditions: When indoor fan speed keeps too low (300RPM) for certain time, the unit will stop and the LED will display the failure

Supposed causes: Wiring mistake. Fan assembly faulty. Fan motor faulty. PCB faulty.

Troubleshooting

Klimaire Air Conditioner Troubleshooting
Klimaire Air Conditioner Troubleshooting

The following problems are not a malfunction and in most situations will not require repairs.

ProblemsCauses
The motor is heard operating but the air-conditioner dose not work when the indoor unit is powered onSince the air-conditioner is powered on, it will come to working condition as long as you press the ON/OFF button of the remote control and the Signal is well received.
The compressor stops running but the indoor fan motor keeps working when it is at cooling mode with the indoor temperature higher than set temperatureIf you turn off the air-conditioner and restart it immediately, it will return to normal in 3 minutes, after that, the air-conditioner will automatically adjust the indoor fan speed to what you set.
The compressor works discontinuously at dehumidifying modeThe air-conditioner will automatically control the working of the compressor according to the inside temperature.
The air-conditioner does not work while the LED display is onThe TIMER is set with the air-conditioner; it will be in hold on condition. If the TIMER setting is cancelled, the air-conditioner will return to normal working condition.
The compressor works discontinuously at cooling and dehumidifying mode, and the indoor fan motor slows downThe compressor stops internally or the fan motor slows down to prevent the indoor heat exchanger from being frozen.

Issue: Unit does not turn on when pressing ON/OFF button

Possible Causes: The Unit has a 3-minute protection feature that prevents the unit from overloading. The unit cannot be restarted within three minutes of being turned off.

Issue: The unit changes from COOL/HEAT mode to FAN mode

Possible Causes:

  • The unit may change its setting to prevent frost from forming on the unit. Once the temperature increases, the unit will start operating in the previously selected mode again.
  • The set temperature has been reached, at which point the unit turns off the compressor. The unit will continue operating when the temperature fluctuates again.

Issue: The indoor unit emits white mist

Possible Causes: In humid regions, a large temperature difference between the room’s air and the conditioned air can cause white mist.

Issue: The indoor unit makes noises

Possible Causes:

  • A rushing air sound may occur when the louver resets its position.
  • A squeaking sound may occur after running the unit in HEAT mode due to expansion and contraction of the unit’s plastic parts.

How to operate your unit without the remote control?

In the event that your remote control fails to work, your unit can be operated manually with the MANUAL CONTROL button located on the indoor unit. Note that manual operation is not a long-term solution, and that operating the unit with your remote control is strongly recommended.

How to operate your unit without the remote control
How to operate your unit without the remote control

To operate your unit manually:

  1. Open the front panel of the indoor unit.
  2. Locate the MANUAL CONTROL button on the right-hand side of the unit.
  3. Press the MANUAL CONTROL button one time to activate FORCED AUTO mode.
  4. Press the MANUAL CONTROL again to activate FORCED COOLING mode.
  5. Press the MANUAL CONTROL button a third time to turn the unit off.
  6. Close the front panel.

Cleaning Your Air Filter

A clogged air conditioner can reduce the cooling efficiency of your unit, and can also be bad for your health. Make sure to clean the filter once every two weeks.

Cleaning Your Air Filter
Cleaning Your Air Filter
  1. Lift the front panel of the indoor unit.
  2. Grip the tab on the end of the filter, push it up slightly, then pull it a little towards yourself.
  3. Now pull down to extract the filter.
  4. If your filter has a small air freshening filter, unclip it from the larger filter. Clean this air freshening filter with a hand-held vacuum.
  5. Clean the large air filter with warm, soapy water. Be sure to use a mild detergent.
  6. Rinse the filter with fresh water, then shake off excess water.
  7. Dry it in a cool, dry place, and refrain from exposing it to direct sunlight.
  8. When dry, re-clip the air freshening filter to the larger filter, then slide it back into the indoor unit.
  9. Close the front panel of the indoor unit.

Klimaire Air Conditioner Manual PDF

Comments

Popular posts from this blog

Rittal Air Conditioner Error Codes

  System messages are shown on the display screen of the Comfort controller via the displays A1 to A20 and E0. Rittal Air Conditioner Error Codes Error Codes System message Possible cause A1 Enclosure door open Door open or door limit switch incorrectly positioned A2 Internal temperature of enclosure too high Cooling capacity inadequate/unit undersized. Error as a consequence of messages A03 to A17. A3 Filter monitoring Filter mat soiled A4 Ambient temperature too high/too low Ambient temperature outside of admissible operating range (+10°C to +60°C) A5 Icing hazard Operational display in case of icing hazard. A6 PSAH pressure-operated switch Ambient temperature too high A7 Evaporator coil Lack of coolant; sensor in front of or behind condenser defective. A8 Condensate warning Condensate discharge kinked or blocked A9 Condenser fan blocked or defective Blocked or defective A10 Evaporator fan blocked or defective Blocked or defective A11 Compressor Compressor overloaded A12 Condense...

Samsung DVM-S VRF Error Codes

  DVM Digital Variable Multi VRF Systems Error Codes Samsung DVM VRF Error Codes Error code related indoor unit: Error Codes Explanation E-101 Indoor unit communication error. Indoor unit can not receive any data from outdoor unit. E-102 Communication error between indoor unit and outdoor unit. Displayed in indoor unit. E-108 Error due to repeated address setting (When 2 or more devices has same address within the network) E-121 Error on indoor temperature sensor of indoor unit (Short or Open) E-122 Error on EVA IN sensor of indoor unit (Short or Open) E-123 Error on EVA OUT sensor of indoor unit (Short or Open) E-128 EVA IN temperature sensor of indoor unit is detached from EVA IN pipe E-129 EVA OUT temperature sensor of indoor unit is detached from EVA OUT pipe E-130 Heat exchanger in/out sensors of indoor unit are detached E-135 RPM feedback error of indoor unit's cleaning fan E-149 Error due to AHU master indoor unit sensor setting. E-151 Error due to opened EEV of indoor unit ...

Panasonic VRF AC Error Codes and Troubleshooting

  Indoor unit is detecting error signal from remote controller (and system controller). Panasonic Mini VRF AC Error Codes and Troubleshooting Error Codes Meaning E01 Error in receiving serial communication signal. E02 Error in transmitting serial communication signal. E03 Indoor unit is detecting error signal from remote controller. E04 Error in receiving serial communication signal. When turning on the power supply, the number of connected indoor units does not correspond to the number set. E06 Error of the outdoor unit in receiving serial communication signal from the indoor unit. E08 Indoor unit address setting is duplicated. E09 Remote controller address connector. E12 Starting auto address setting is prohibited. This alarm message shows that the auto address connector CN-A.ADD is shorted while other RC line is executing auto address operation. E15 Error in auto address setting. E16 Error in auto address setting. E20 No indoor unit is connected during auto address setting. E24 ...