Insignia Portable Air Conditioner Error Codes

 When any of the following error indicators appear on the LED display, turn off your air conditioner and call a professional maintenance technician or service center.

Insignia Portable Air Conditioner Error Codes
Insignia Portable Air Conditioner Error Codes
Error CodesProblem
FLThe water collection tank is full and must be drained. Drain the tank and reset your settings.
E1Coil temperature sensor error
E2Indoor temperature sensor error
E3Anti-freezing protection. The air conditioner coil temperature is too low and the unit has turned off automatically. The unit resets itself when the temperature reaches 46.4°F (8°C).

Troubleshooting

Problem: Air conditioner does not start

Possible cause:

  1. The air conditioner is unplugged.
  2. The fuse on the circuit is blown or the circuit breaker is tripped.
  3. Power failure.
  4. The current interrupter device in the power cord has tripped.
  5. FL appears on the display.
  6. Room temperature is less than the set temperature.

Possible solution:

  1. Make sure that the air conditioner is plugged in and that the plug is pushed completely into the outlet.
  2. Check the house fuse/circuit breaker box and replace the fuse or reset the circuit breaker.
  3. If a power failure occurs, the air conditioner turns off. When the power is restored, wait three minutes to  restart the air conditioner to prevent tripping the compressor overload.
  4. Press the RESET button located on the power cord plug. If the RESET button will not stay engaged, discontinue use of the air conditioner and contact a qualified service technician.
  5. The water collection tank is full and must be drained. Drain the tank and reset your settings.
  6. This is normal. The air conditioner automatically shuts off when the room temperature equals, or is less than, the set temperature. Adjust the temperature setting, if needed.

Problem: The air conditioner does not cool

Possible cause:

  1. Airflow is restricted.
  2. The temperature control may not be set correctly
  3. The air filter is dirty.
  4. There is a heat source or too many people in the room.
  5. The room may have been hot.
  6. The exhaust hose is not connected or is blocked.

Possible solution:

  1. Make sure that there are no curtains, blinds, or furniture blocking the front of the air conditioner.
  2. In COOL mode, decrease the temperature setting by pressing the ∇ button on the panel or the remote control.
  3. Clean the filter at lease every two weeks.
  4. Move any heat sources from the room.
  5. You need to allow time for the room to cool down after you first turn on the air conditioner.
  6. Connect the exhaust hose and make sure that it is not obstructed and is functioning properly.

Problem: The air conditioner is freezing up

Possible cause: The cooling coils are iced over.

Possible solution: Ice may block the air flow and obstruct the air conditioner from properly cooling the room. Set the mode control to High Fan or High Cool.

Problem: The air conditioner runs too often or too long

Possible cause:

  1. The area to be cooled is too large for the air conditioner.
  2. Doors or windows are open.

Possible solution:

  1. Consult your Insignia technician for the air conditioner capacity required to cool the desired area.
  2. Make sure that doors and windows are closed.

Problem: The venting hose is hot

Possible cause: When the air conditioner runs continuously for a long time, the hose becomes hot.

Possible solution: This is normal.

Problem: The air conditioner is too loud

Possible cause:

  1. The unit may seem rather loud for the first two or three minutes of operation.
  2. A soft, swishing noise can be heard immediately after turning the unit on or off, and during operation.

Possible solution:

  1. This is the sound of the compressor starting up and is normal.
  2. This is the sound of the liquid refrigerant flowing in the unit and is normal.

Problem: The air conditioner makes an odd noise

Possible cause: An audible gurgling noise may be heard when the unit is operated on a gently sloping floor.

Possible solution: Place the unit on a level floor.

Manual PDF

Comments

Popular posts from this blog

Rittal Air Conditioner Error Codes

  System messages are shown on the display screen of the Comfort controller via the displays A1 to A20 and E0. Rittal Air Conditioner Error Codes Error Codes System message Possible cause A1 Enclosure door open Door open or door limit switch incorrectly positioned A2 Internal temperature of enclosure too high Cooling capacity inadequate/unit undersized. Error as a consequence of messages A03 to A17. A3 Filter monitoring Filter mat soiled A4 Ambient temperature too high/too low Ambient temperature outside of admissible operating range (+10°C to +60°C) A5 Icing hazard Operational display in case of icing hazard. A6 PSAH pressure-operated switch Ambient temperature too high A7 Evaporator coil Lack of coolant; sensor in front of or behind condenser defective. A8 Condensate warning Condensate discharge kinked or blocked A9 Condenser fan blocked or defective Blocked or defective A10 Evaporator fan blocked or defective Blocked or defective A11 Compressor Compressor overloaded A12 Condense...

Samsung DVM-S VRF Error Codes

  DVM Digital Variable Multi VRF Systems Error Codes Samsung DVM VRF Error Codes Error code related indoor unit: Error Codes Explanation E-101 Indoor unit communication error. Indoor unit can not receive any data from outdoor unit. E-102 Communication error between indoor unit and outdoor unit. Displayed in indoor unit. E-108 Error due to repeated address setting (When 2 or more devices has same address within the network) E-121 Error on indoor temperature sensor of indoor unit (Short or Open) E-122 Error on EVA IN sensor of indoor unit (Short or Open) E-123 Error on EVA OUT sensor of indoor unit (Short or Open) E-128 EVA IN temperature sensor of indoor unit is detached from EVA IN pipe E-129 EVA OUT temperature sensor of indoor unit is detached from EVA OUT pipe E-130 Heat exchanger in/out sensors of indoor unit are detached E-135 RPM feedback error of indoor unit's cleaning fan E-149 Error due to AHU master indoor unit sensor setting. E-151 Error due to opened EEV of indoor unit ...

Panasonic VRF AC Error Codes and Troubleshooting

  Indoor unit is detecting error signal from remote controller (and system controller). Panasonic Mini VRF AC Error Codes and Troubleshooting Error Codes Meaning E01 Error in receiving serial communication signal. E02 Error in transmitting serial communication signal. E03 Indoor unit is detecting error signal from remote controller. E04 Error in receiving serial communication signal. When turning on the power supply, the number of connected indoor units does not correspond to the number set. E06 Error of the outdoor unit in receiving serial communication signal from the indoor unit. E08 Indoor unit address setting is duplicated. E09 Remote controller address connector. E12 Starting auto address setting is prohibited. This alarm message shows that the auto address connector CN-A.ADD is shorted while other RC line is executing auto address operation. E15 Error in auto address setting. E16 Error in auto address setting. E20 No indoor unit is connected during auto address setting. E24 ...