If any error occurs in your air conditioner, indoor display shows error codes. Following are the error code for respective error: Though your AC shows fault code on the display, it will remain ON for particular faults to make your comfortable. But your have to call service person for repair.

Error CodesFailure/Protection
E1System Hi Pressure Protection
E2Inner anti-frozen protection
E3System Low Pressure Protection
E4Compressor Discharge Pressure
E5Low Voltage Over-current Protect
E6Communication Failure
E7Mode Conflict
E8Anti-Hi Temp Protection
E9Anti Cold Wind Protection
E0Lower running frequency due Low-Voltage of Power Supply
H6No response from indoor motor. PCB failure
F1Indoor environment temp. sensor short or open circuit
F2Indoor evaporator temp. sensor short or open circuit
F3Outdoor environment temp. sensor short or open circuit
F4Outdoor condenser temp. sensor short or open circuit
F5Outdoor discharge temp. sensor short or open circuit
F6Lower running frequency due to cooling overloaded
F7Oil return in cooling mode
F8lower running frequency due to over current
F9lower running frequency due discharge pressure too high
H1Defrost
H2Static dust removing protection
H3Compressor overload protection
H4System abnormal
H5Module protection
H7Synchronization failure
H8Water full protection
H9Electric Heater Malfunction
H0Lower frequency for antihigh-temp in heating mode
FALower running frequency due to high pipe temp.
FHLower running frequency due to anti-freeze
C5No Jumper
Godrej AC Remote Control Display
Godrej AC Remote Control Display

Troubleshooting

Please check below items before asking for maintenance. If the malfunction still can’t be eliminated, please contact local dealer or qualified professionals.

Godrej AC Remote Control Button Meanings
Godrej AC Remote Control Button Meanings

Indoor unit can’t receive remote controller’s signal or remote controller has no action.

Check items

  1. Whether it’s interfered severely (such as static electricity, stable voltage)?
  2. Whether remote controller is within the signal receiving range?
  3. Whether there are obstacles?
  4. Whether remote controller is pointing at the receiving window?
  5. Is sensitivity of remote controller low; fuzzy display and no display?
  6. No display when operating remote controller?
  7. Fluorescent lamp in room?

Solution

  1. Pull out the plug. Reinsert the plug after about 3min, and then turn on the unit again.
  2. Signal receiving range is 8m.
  3. Remove obstacles.
  4. Select proper angle and point the remote controller at the receiving window on indoor unit.
  5. Check the batteries. If the power of batteries is too low, please replace them.
  6. Check whether remote controller appears to be damaged. If yes, replace it.
  7. Take the remote controller close to indoor unit or Turn off the fluoresent lamp and then try it again.

No air emitted from indoor unit

Check items

  1. Air inlet or air outlet of indoor unit is blocked?
  2. Air inlet or air outlet of indoor unit is blocked?
  3. Heating mode is turned on just now?

Solution

  1. Eliminate obstacles.
  2. After reaching to set temperature, indoor unit will stop blowing out air.
  3. In order to prevent blowing out cold air, indoor unit will be started after delaying for sev- eral minutes, which is a normal phenomenon.

Air conditioner can’t operate

Check items

  1. Power failure?
  2. Is plug loose?
  3. Circuit break trips off or fuse is burnt out?
  4. Wiring has malfunction?
  5. Unit has restarted immediately after stopping operation?
  6. Whether the function setting for remote controller is correct?

Solution

  1. Wait until power recovery
  2. Reinsert the plug
  3. Ask professional to replace circuit break or fuse
  4. Ask professional to replace it
  5. Wait for 3min, and then turn on the unit again
  6. Reset the function

Cooling (heating) effect is not good

Check items

  1. Voltage is too low?
  2. Filter is dirty?
  3. Set temperature is in proper range?
  4. Door and window are open?

Solution

  1. Wait until the voltage resumes normal.
  2. Clean the filter.
  3. Adjust temperature to proper range.
  4. Close door and window.

“Water flowing” noise

Check items

  1. Air conditioner is turned on or turned off just now?

Solution

  1. The noise is the sound of refrigerant flowing inside the unit, which is a normal phenomenon.

Cracking noise

Check items

  1. Air conditioner is turned on or turned off just now?

Solution

  1. This is the sound of friction caused by expansion and/or contraction of panel or other parts due to the change of temperature.

Clean Filter

Godrej AC Clean Filter
Godrej AC Clean Filter
  1. Open panel: Pull out the panel to a certain angle as shown in the fig.
  2. Remove filter: Remove the filter as indicated in the fig.
  3. Use dust catcher or water to clean filter. When the filter is very dirty, use the water (below 45℃) to clean it, and then put it in a shady and cool place to dry.
  4. Install filter: Install the filter and then close the paneş cover tightly.
Location of controls
Location of controls

Download Godrej AC 5160 Owner’s Manual PDF

Comments

Popular posts from this blog

Rittal Air Conditioner Error Codes

  System messages are shown on the display screen of the Comfort controller via the displays A1 to A20 and E0. Rittal Air Conditioner Error Codes Error Codes System message Possible cause A1 Enclosure door open Door open or door limit switch incorrectly positioned A2 Internal temperature of enclosure too high Cooling capacity inadequate/unit undersized. Error as a consequence of messages A03 to A17. A3 Filter monitoring Filter mat soiled A4 Ambient temperature too high/too low Ambient temperature outside of admissible operating range (+10°C to +60°C) A5 Icing hazard Operational display in case of icing hazard. A6 PSAH pressure-operated switch Ambient temperature too high A7 Evaporator coil Lack of coolant; sensor in front of or behind condenser defective. A8 Condensate warning Condensate discharge kinked or blocked A9 Condenser fan blocked or defective Blocked or defective A10 Evaporator fan blocked or defective Blocked or defective A11 Compressor Compressor overloaded A12 Condense...

Samsung DVM-S VRF Error Codes

  DVM Digital Variable Multi VRF Systems Error Codes Samsung DVM VRF Error Codes Error code related indoor unit: Error Codes Explanation E-101 Indoor unit communication error. Indoor unit can not receive any data from outdoor unit. E-102 Communication error between indoor unit and outdoor unit. Displayed in indoor unit. E-108 Error due to repeated address setting (When 2 or more devices has same address within the network) E-121 Error on indoor temperature sensor of indoor unit (Short or Open) E-122 Error on EVA IN sensor of indoor unit (Short or Open) E-123 Error on EVA OUT sensor of indoor unit (Short or Open) E-128 EVA IN temperature sensor of indoor unit is detached from EVA IN pipe E-129 EVA OUT temperature sensor of indoor unit is detached from EVA OUT pipe E-130 Heat exchanger in/out sensors of indoor unit are detached E-135 RPM feedback error of indoor unit's cleaning fan E-149 Error due to AHU master indoor unit sensor setting. E-151 Error due to opened EEV of indoor unit ...

Panasonic VRF AC Error Codes and Troubleshooting

  Indoor unit is detecting error signal from remote controller (and system controller). Panasonic Mini VRF AC Error Codes and Troubleshooting Error Codes Meaning E01 Error in receiving serial communication signal. E02 Error in transmitting serial communication signal. E03 Indoor unit is detecting error signal from remote controller. E04 Error in receiving serial communication signal. When turning on the power supply, the number of connected indoor units does not correspond to the number set. E06 Error of the outdoor unit in receiving serial communication signal from the indoor unit. E08 Indoor unit address setting is duplicated. E09 Remote controller address connector. E12 Starting auto address setting is prohibited. This alarm message shows that the auto address connector CN-A.ADD is shorted while other RC line is executing auto address operation. E15 Error in auto address setting. E16 Error in auto address setting. E20 No indoor unit is connected during auto address setting. E24 ...