Global Air Portable Air Conditioner Error Codes

 Global Air GLA-08c Portable AC Error Codes and Troubleshooting. Please check the unit and suggestions below before asking for professional service, but never dismantle or repairthe unit by yourself, it may cause harm to you and your property.

Global Air GLA-08c Portable AC Error Codes and Troubleshooting
Global Air GLA-08c Portable AC Error Codes and Troubleshooting
TroubleCause-Remedy
LED displays error code “E1”Tube temperature sensor failure. Check the tube temperature sensor and related circuits
LED displays error code “E2”Room temperature sensor failure. Check the room temperature sensor and related circuits.
LED displays error code “E4”Anti-freeze protection. Restore the functions automatically once anti-freeze protection is over.
Water-full indicator lightsThe water in chassis is full. Drain the water and re-start the unit
The compressor does not workInitiation of overheat protection. Wait until the temperature decrease, the unit will re-start automatically.
High noise levelThe unit is being placed at uneven surface. Put the unit at a flat and firm place (may reduce noise)

Trouble: The unit fails to start up

Cause:

  1. Power supply failure
  2. Water-full and its indicator lighting up
  3. Ambient temperature too low or too high
  4. The room temperature is lower than the set temperature in cooling mode

Remedy:

  1. Connect the unit to a live socket and turn it on
  2. Drain the water stored in the unit
  3. It is recommended to use this unit between 50-95 ℉ (10-35℃)
  4. Change the set temperature

Trouble: Bad cooling effects

Cause:

  1. There is direct sunlight
  2. The doors and windows are open, the room is crowded or there are other heat sources
  3. Dirty filter
  4. Air inlet or air outlet clogged

Remedy:

  1. Close the curtain
  2. Close the door and window, remove other heat sources, and add new air-conditioners
  3. Clean or replace the filter
  4. Remove the obstruction

Trouble: The remote control does not work

Cause:

  1. Too long distance
  2. The remote control didn’t aim at signal receptor on unit
  3. The batteries have no electricity

Remedy:

  1. Bring the remote control close to the air-conditioner and ensure airs at signal receptor on unit.
  2. Bring the remote control close to the air-conditioner and ensure airs at signal receptor on unit.
  3. Replace the batteries

Maintenance and Service

Global Air GLA Portable AC Maintenance and Service
Global Air GLA Portable AC Maintenance and Service

Remark: Turn off the unit and pull out the plug before maintain or send the unit to service center.

1. Surface cleaning

Clean the unit surface with wet and soft cloth, but do not use chemical solvents such as alcohol and gasoline to avoid any damage to unit.

2. Filter cleaning

Clean the filter every two weeks, otherwise it would influence the unit performance if filter clogged with dust.

  • Grip the filter handle and take it out gently in correct direction (as Photo).
  • Clean the filters gently in warm water (about 104℉ (40℃)) mixed with detergent, and dry in the shade (as Photo).
  • Push filter in even force gently into correct place to avoid any damage.

Global Air GLA-08c Portable AC Manual PDF

Comments

Popular posts from this blog

Rittal Air Conditioner Error Codes

  System messages are shown on the display screen of the Comfort controller via the displays A1 to A20 and E0. Rittal Air Conditioner Error Codes Error Codes System message Possible cause A1 Enclosure door open Door open or door limit switch incorrectly positioned A2 Internal temperature of enclosure too high Cooling capacity inadequate/unit undersized. Error as a consequence of messages A03 to A17. A3 Filter monitoring Filter mat soiled A4 Ambient temperature too high/too low Ambient temperature outside of admissible operating range (+10°C to +60°C) A5 Icing hazard Operational display in case of icing hazard. A6 PSAH pressure-operated switch Ambient temperature too high A7 Evaporator coil Lack of coolant; sensor in front of or behind condenser defective. A8 Condensate warning Condensate discharge kinked or blocked A9 Condenser fan blocked or defective Blocked or defective A10 Evaporator fan blocked or defective Blocked or defective A11 Compressor Compressor overloaded A12 Condense...

Panasonic VRF AC Error Codes and Troubleshooting

  Indoor unit is detecting error signal from remote controller (and system controller). Panasonic Mini VRF AC Error Codes and Troubleshooting Error Codes Meaning E01 Error in receiving serial communication signal. E02 Error in transmitting serial communication signal. E03 Indoor unit is detecting error signal from remote controller. E04 Error in receiving serial communication signal. When turning on the power supply, the number of connected indoor units does not correspond to the number set. E06 Error of the outdoor unit in receiving serial communication signal from the indoor unit. E08 Indoor unit address setting is duplicated. E09 Remote controller address connector. E12 Starting auto address setting is prohibited. This alarm message shows that the auto address connector CN-A.ADD is shorted while other RC line is executing auto address operation. E15 Error in auto address setting. E16 Error in auto address setting. E20 No indoor unit is connected during auto address setting. E24 ...

Vestel AC Error Codes and Troubleshooting

  Error Messages   are displayed, respectively by first the   Er   icon and then the special code (01, 02, …, 20, etc.) of the failure. In that case, do nothing to the air conditioner and contact with the Authorised Service.   Er11   and   Er13   are not error messages. If you see these messages, apply the steps under the following protection messages section. Vestel AC Error Code and Troubleshooting Error Codes Cause dF The icing on the outdoor unit is being defrosted. After the defrosting operation is accomplished, your air conditioner will continue to operate in the heating mode, the product should not be turned off while this mode is enabled. RE Make the arc control for your electrical wiring, if the problem is not fixed call for the service. If the problem comes out very frequently, contact with the authorised service. Sr In case of certain failures, in order to not to spoil you comfort, your air conditioner continues to operate despite the f...