Galanz Air Conditioner Error Codes

 When the outdoor coil pipe TEMP sensor is out of order or removed, the air conditioner will set to defrost automatically in order to prevent it not working normally while the outdoor coil pipe TEMP sensor  is malfunction.

Fault F6: PG motor faults

Fault F7: Indoor TEMP sensor faults

Fault F8: Indoor coil pipe TEMP sensor faults

Fault F9: Outdoor coil pipe TEMP sensor faults

Galanz Air Conditioner Error Codes
Galanz Air Conditioner Error Codes

Wall Mounted Type

Indoor unit display and solve methods of protector stop ingredients in indoor unit and outdoor unit

Error CodesTrouble
F1Heat overloading protector
F2Cool freeze protector
F3Instantaneous power cut
F4direct current fan motor no feedback
1Fcool overloading protector
2Fexhaust overheating protector
3Fover or not enough pressure protector
4Fover-current protector
5FIPM protector
6Fdefrost state
7Fdirect current compressor drive exceptional
8Fdirect current compressor cannt start
Galanz Air Conditioner Remote Control
Galanz Air Conditioner Remote Control

Trouble Solve Methods

E1: The trouble of indoor unit room temperature sensor.

E2: The trouble of unit pipe temperature sensor. indoor

E3: The trouble of PG motor

E5: The trouble of bad communication of indoor unit and outdoor unit.

E6: The EEPRO of indoor unit error

1E: The trouble of outdoor unit pipe temperature sensor

3E: The trouble of exhaust sensor

4E: The EEPRO of indoor unit error

8E: The trouble of PFC.

Troubleshooting

Operation of air conditioner: Fan speed setting is not allowed in AUTO or DRY mode

Explanation: The speed of the indoor fan is set to low in DRY mode. Fan speed of 3 steps is selected automatically in AUTO mode

Operation of air conditioner: Compressor stops operation intermittently in DRY mode

Explanation: Compressor operation is automatically controlled in DRY mode depending on the room temperature and humidity

Operation of air conditioner: Compressor of the outdoor unit is operating although it is turned off in HEAT mode

Explanation: When the unit is turned off while de-ice is activated, the compressor continues operation for up to 10 minutes (maximum) until the deice is completed

Operation of air conditioner: Timer indicator lamp lights up and the air conditioner does not operate

Explanation: Timer is being activated and the unit is in ready mode. The unit operates normally if the timer operation is cancelled

Operation of air conditioner: The compressor and indoor fan stop intermittently in HEAT mode

Explanation: The compressor and indoor fan stop intermittently if room temperature exceeds a setting temperature in order to protect the compressor from overheated air in HEAT mode

Operation of air conditioner: Indoor fan and outdoor fan stop intermittently in HEAT mode

Explanation: The compressor operates in a reverse cycle to remove exterior ice in HEAT mode, and indoor fan and outdoor fan do not operate intermittently for within 20% of the total heat operation

Operation of air conditioner: The compressor stops intermittently in COOL mode or DRY mode, and fan speed of the indoor unit decreases

Explanation: The compressor stops intermittently or the fan speed of the indoor unit decreases to prevent inside/outside air frozen depending on the inside/outside air temperature.

Galanz Air Conditioner Manual PDF

Comments

Popular posts from this blog

Rittal Air Conditioner Error Codes

  System messages are shown on the display screen of the Comfort controller via the displays A1 to A20 and E0. Rittal Air Conditioner Error Codes Error Codes System message Possible cause A1 Enclosure door open Door open or door limit switch incorrectly positioned A2 Internal temperature of enclosure too high Cooling capacity inadequate/unit undersized. Error as a consequence of messages A03 to A17. A3 Filter monitoring Filter mat soiled A4 Ambient temperature too high/too low Ambient temperature outside of admissible operating range (+10°C to +60°C) A5 Icing hazard Operational display in case of icing hazard. A6 PSAH pressure-operated switch Ambient temperature too high A7 Evaporator coil Lack of coolant; sensor in front of or behind condenser defective. A8 Condensate warning Condensate discharge kinked or blocked A9 Condenser fan blocked or defective Blocked or defective A10 Evaporator fan blocked or defective Blocked or defective A11 Compressor Compressor overloaded A12 Condense...

Panasonic VRF AC Error Codes and Troubleshooting

  Indoor unit is detecting error signal from remote controller (and system controller). Panasonic Mini VRF AC Error Codes and Troubleshooting Error Codes Meaning E01 Error in receiving serial communication signal. E02 Error in transmitting serial communication signal. E03 Indoor unit is detecting error signal from remote controller. E04 Error in receiving serial communication signal. When turning on the power supply, the number of connected indoor units does not correspond to the number set. E06 Error of the outdoor unit in receiving serial communication signal from the indoor unit. E08 Indoor unit address setting is duplicated. E09 Remote controller address connector. E12 Starting auto address setting is prohibited. This alarm message shows that the auto address connector CN-A.ADD is shorted while other RC line is executing auto address operation. E15 Error in auto address setting. E16 Error in auto address setting. E20 No indoor unit is connected during auto address setting. E24 ...

Vestel AC Error Codes and Troubleshooting

  Error Messages   are displayed, respectively by first the   Er   icon and then the special code (01, 02, …, 20, etc.) of the failure. In that case, do nothing to the air conditioner and contact with the Authorised Service.   Er11   and   Er13   are not error messages. If you see these messages, apply the steps under the following protection messages section. Vestel AC Error Code and Troubleshooting Error Codes Cause dF The icing on the outdoor unit is being defrosted. After the defrosting operation is accomplished, your air conditioner will continue to operate in the heating mode, the product should not be turned off while this mode is enabled. RE Make the arc control for your electrical wiring, if the problem is not fixed call for the service. If the problem comes out very frequently, contact with the authorised service. Sr In case of certain failures, in order to not to spoil you comfort, your air conditioner continues to operate despite the f...