Fisher Air Conditioner Error Codes and Troubleshooting
Fisher Air Conditioner Error Codes and Troubleshooting
Error CodeCause
E0Indoor unit EEPROM parameter error
E1Indoor / outdoor units communication error
E3Indoor fan speed has been out of control
E4Indoor room temperature sensor T1 open circuit or short circuit
E5Evaporator coil temperature sensor T2 open circuit or short circuit
ECRefrigerant leakage detection
F0Overload current protection
F1Outdoor ambient temperature sensor T4 open circuit or short circuit
F2Condenser coil temperature sensor T3 open circuit or short circuit
F3Compressor discharge temperature sensor T5 open circuit or short circuit
F4Outdoor unit EEPROM parameter error
F5Outdoor fan speed has been out of control
P0IPM malfunction or IGBT over-strong current protection
P1 Over voltage or over low voltage protection
P2High temperature protection of IPM module or compressor top
P4Inverter compressor drive error

Fault Symptom: The display board shows a garbled code or a code that is not an error code found in the service manual nor a temperature reading.

Fisher DC Inverter Floor Ceiling Type AC Error Codes:

Fisher DC Inverter Floor Ceiling Type AC Error Codes
Fisher DC Inverter Floor Ceiling Type AC Error Codes
  • DC Inverter Floor Ceiling Type Air Conditioner
  • E0 Water Pump Malfunction
  • E1 High pressure protection of compressor
  • E3 Low pressure protection of compressor
  • E4 High discharge temperature protection of compressor
  • E5 Compressor overload or drive error
  • E6 Communication malfunction
  • E9 Water overflow protection
  • F0 Indoor unit ambient sensor malfunction at air return opening
  • F1 Evaporator sensor malfunction
  • F2 Condenser sensor malfunction
  • F3 Outdoor unit ambient temperature sensor malfunction
  • F4 Discharge temperature sensor malfunction
  • F5 Ambient sensor malfunction on Displayer (or LED board)

If there is malfunction during running of the system, LCD will display error code at temperature–displayed location. Once there is more than one malfunction, error codes will be displayed circularly. If there are multiple circuit systems, the system number of failed system will be displayed before the colon (not for single system). If malfunction occurs, turn off the unit and contact nearest dealer for help.

Fisher Portable AC Error Codes:

E1: Room temperature sensor error. Unplug the unit and plug it back in. If error repeats, call for service.

E2: Evaporator temperature sensor error. Unplug the unit and plug it back in. If error repeats, call for service.

E3: Condenser temperature sensor error. Unplug the unit and plug it back in. If error repeats, call for service (on some models).

E4: Display panel communication error. Unplug the unit and plug it back in. If error repeats, call for service.

P1: Bottom tray is full. Connect the drain hose and drain the collected water away. If protection repeats, call for service.

Troubleshooting

Problem: The unit does not run.

Solutions:

  • check if the power supply is in order.
  • check if the timer switch is on or not.

Problem: The air conditioner runs but does not cool enough.

Solutions:

  • Check if the preset temperature is too high.
  • Check if the sunlight shines directly into the room.
  • Check if the door and window are opened.
  • Check if there is anything blocking the air discharge.
  • Check if the exhaust fan still operates.
  • Check if the air filter is dirty or clogged.

Problem: Vapor or mist fume comes out from the unit when it runs.

Solutions: check if the hot air in the room is mixed with cool air, which may cause smog.

Problem: The remote controller works abnormally.

Solutions:

  • check if the batteries are inserted in correct directions.
  • check if the batteries are exhausted.

Fisher Air Conditioner Manual PDF

Comments

Popular posts from this blog

Rittal Air Conditioner Error Codes

  System messages are shown on the display screen of the Comfort controller via the displays A1 to A20 and E0. Rittal Air Conditioner Error Codes Error Codes System message Possible cause A1 Enclosure door open Door open or door limit switch incorrectly positioned A2 Internal temperature of enclosure too high Cooling capacity inadequate/unit undersized. Error as a consequence of messages A03 to A17. A3 Filter monitoring Filter mat soiled A4 Ambient temperature too high/too low Ambient temperature outside of admissible operating range (+10°C to +60°C) A5 Icing hazard Operational display in case of icing hazard. A6 PSAH pressure-operated switch Ambient temperature too high A7 Evaporator coil Lack of coolant; sensor in front of or behind condenser defective. A8 Condensate warning Condensate discharge kinked or blocked A9 Condenser fan blocked or defective Blocked or defective A10 Evaporator fan blocked or defective Blocked or defective A11 Compressor Compressor overloaded A12 Condense...

Samsung DVM-S VRF Error Codes

  DVM Digital Variable Multi VRF Systems Error Codes Samsung DVM VRF Error Codes Error code related indoor unit: Error Codes Explanation E-101 Indoor unit communication error. Indoor unit can not receive any data from outdoor unit. E-102 Communication error between indoor unit and outdoor unit. Displayed in indoor unit. E-108 Error due to repeated address setting (When 2 or more devices has same address within the network) E-121 Error on indoor temperature sensor of indoor unit (Short or Open) E-122 Error on EVA IN sensor of indoor unit (Short or Open) E-123 Error on EVA OUT sensor of indoor unit (Short or Open) E-128 EVA IN temperature sensor of indoor unit is detached from EVA IN pipe E-129 EVA OUT temperature sensor of indoor unit is detached from EVA OUT pipe E-130 Heat exchanger in/out sensors of indoor unit are detached E-135 RPM feedback error of indoor unit's cleaning fan E-149 Error due to AHU master indoor unit sensor setting. E-151 Error due to opened EEV of indoor unit ...

Panasonic VRF AC Error Codes and Troubleshooting

  Indoor unit is detecting error signal from remote controller (and system controller). Panasonic Mini VRF AC Error Codes and Troubleshooting Error Codes Meaning E01 Error in receiving serial communication signal. E02 Error in transmitting serial communication signal. E03 Indoor unit is detecting error signal from remote controller. E04 Error in receiving serial communication signal. When turning on the power supply, the number of connected indoor units does not correspond to the number set. E06 Error of the outdoor unit in receiving serial communication signal from the indoor unit. E08 Indoor unit address setting is duplicated. E09 Remote controller address connector. E12 Starting auto address setting is prohibited. This alarm message shows that the auto address connector CN-A.ADD is shorted while other RC line is executing auto address operation. E15 Error in auto address setting. E16 Error in auto address setting. E20 No indoor unit is connected during auto address setting. E24 ...