Everstar AC Error Codes and Troubleshooting

 Everstar Portable Air Conditioner Error Codes;

Everstar AC Error Codes and Troubleshooting
Everstar AC Error Codes and Troubleshooting
Error CodesProblem-Solution
P1The LCD window will shows "P1" and the Water Full indicator will flash every 0.5 seconds.
P2Compressor does not work and the digital display area shows “ P2 ". The bottom tray is full
E1The cooting indicator light flashes at 1H: and the digital display area shows “E1 ". The room temperature Sensor is off or shon-circuit.
E2The FAN indicator light flashes at 1H: and the digital display area shows “ E2 ". The Evaporator Temperature Sensor is off or short-circuit.
E3The Dehumidifying indicator light flashes at 1H: and the digital display area shows ''E3''. The Condenser Temperature Sensor is off or short-circuit.

Troubleshooting

Troubles: Unit does not Start when Pressing onloff Button

Possible Causes:

  1. Wateriull indicator blinks, water tank is full.
  2. Room temperature is higher than the set temperature.
  3. Room temperature is lower than the set temperature.

Suggest Remedies:

  1. Dump the water in the water tank.
  2. Reset the temperature.
  3. Reset the temperature.

Troubles: Not cool enough

Possible Causes:

  1. The windows or doors in the room are not closed.
  2. There are heat sources inside the room.
  3. Exhaust air duct is not connected or blocked.
  4. Temperature setting is too high.
  5. Air filter is blocked by dust.

Suggest Remedies:

  1. Make sure all the windows and doors are closed.
  2. Remove the heat sources it possible.
  3. Connect the duct and make sure it can function properly.
  4. Decrease the set temperature.
  5. Clean the air filter.

Troubles: Noisy or vibration

Possible Causes: The ground is not level or not flat enough.

Suggest Remedies: Place the unit on a flat. level ground if possible.

Troubles: Gurgling sound

Possible Causes: The sound comes from the flowing of the refrigerant inside the air conditioner.

Suggest Remedies: It is normal.

How to Fix P1 Error?

How to Fix P1 Error
How to Fix P1 Error

This unit is equipped with a fail-safe switch mechanism which prevents the unit from condensing water in the event the water tank is accidentally displaced, and / or FULL with water. If this situation occurs, the LED window shows “P1” and the WATER FULL indicator light will flash red continuously until the water tank is correctly positioned and/or emptied. Condensed water will be accumulated in the water tank. When the tank is full, the LED window will show “P1” and the Water Full indicator light start flashing. At this time the air cooling process will immediately stop. However, the fan motor will continue to operate (this is normal). Carefully remove the water tank from the cabinet and dispose of the water. Replace the water tank back to it’s original position (in cabinet) and the air cooling process will automatically resume. It may take 3-5 minutes for the compressor to re-start. This is normal.

Everstar Portable Air Conditioner Manual PDF

Comments

Popular posts from this blog

Rittal Air Conditioner Error Codes

  System messages are shown on the display screen of the Comfort controller via the displays A1 to A20 and E0. Rittal Air Conditioner Error Codes Error Codes System message Possible cause A1 Enclosure door open Door open or door limit switch incorrectly positioned A2 Internal temperature of enclosure too high Cooling capacity inadequate/unit undersized. Error as a consequence of messages A03 to A17. A3 Filter monitoring Filter mat soiled A4 Ambient temperature too high/too low Ambient temperature outside of admissible operating range (+10°C to +60°C) A5 Icing hazard Operational display in case of icing hazard. A6 PSAH pressure-operated switch Ambient temperature too high A7 Evaporator coil Lack of coolant; sensor in front of or behind condenser defective. A8 Condensate warning Condensate discharge kinked or blocked A9 Condenser fan blocked or defective Blocked or defective A10 Evaporator fan blocked or defective Blocked or defective A11 Compressor Compressor overloaded A12 Condense...

Samsung DVM-S VRF Error Codes

  DVM Digital Variable Multi VRF Systems Error Codes Samsung DVM VRF Error Codes Error code related indoor unit: Error Codes Explanation E-101 Indoor unit communication error. Indoor unit can not receive any data from outdoor unit. E-102 Communication error between indoor unit and outdoor unit. Displayed in indoor unit. E-108 Error due to repeated address setting (When 2 or more devices has same address within the network) E-121 Error on indoor temperature sensor of indoor unit (Short or Open) E-122 Error on EVA IN sensor of indoor unit (Short or Open) E-123 Error on EVA OUT sensor of indoor unit (Short or Open) E-128 EVA IN temperature sensor of indoor unit is detached from EVA IN pipe E-129 EVA OUT temperature sensor of indoor unit is detached from EVA OUT pipe E-130 Heat exchanger in/out sensors of indoor unit are detached E-135 RPM feedback error of indoor unit's cleaning fan E-149 Error due to AHU master indoor unit sensor setting. E-151 Error due to opened EEV of indoor unit ...

Panasonic VRF AC Error Codes and Troubleshooting

  Indoor unit is detecting error signal from remote controller (and system controller). Panasonic Mini VRF AC Error Codes and Troubleshooting Error Codes Meaning E01 Error in receiving serial communication signal. E02 Error in transmitting serial communication signal. E03 Indoor unit is detecting error signal from remote controller. E04 Error in receiving serial communication signal. When turning on the power supply, the number of connected indoor units does not correspond to the number set. E06 Error of the outdoor unit in receiving serial communication signal from the indoor unit. E08 Indoor unit address setting is duplicated. E09 Remote controller address connector. E12 Starting auto address setting is prohibited. This alarm message shows that the auto address connector CN-A.ADD is shorted while other RC line is executing auto address operation. E15 Error in auto address setting. E16 Error in auto address setting. E20 No indoor unit is connected during auto address setting. E24 ...