Skip to main content

DuctlessAire Air Conditioner Error Codes

 Ductlessair Mini Split AC Error Codes

DuctlessAire Air Conditioner Error Codes
DuctlessAire Air Conditioner Error Codes

Indoor Unit Error Display;

Operation lampTimer lampDisplayLED STATUS
☆ 1 timeXE0Indoor unit EEPROM parameter error
☆ 2 timesXE1Indoor / outdoor units communication error
☆ 3 timesXE2Zero-crossing signal detection error
☆ 4 timesXE3Indoor fan speed has been out of control
☆ 5 timesXE4Indoor room temperature sensor T1 open circuit or short
circuit
☆ 6 timesXE5Evaporator coil temperature sensor T2 open circuit or
short circuit
☆ 7 timesXECRefrigerant leakage detection
☆ 2 timesOF1Outdoor temperature sensor T4 open circuit or short
circuit
☆ 3 timesOF2Condenser coil temperature sensor T3 open circuit or
short circuit
☆ 4 timesOF3Compressor discharge temperature sensor T5 open
circuit or short circuit
☆ 5 timesOF4Outdoor unit EEPROM parameter error
☆ 6 timesOF5Outdoor fan speed has been out of control(only for)
☆ 1 timesP0IPM malfunction or IGBT over-strong current protection
☆ 2 timesP1Over voltage or over low voltage protection
☆ 3 timesP2High temperature protection of compressor top diagnosis
and solution(only for MS11D-21HRDN1-MN5Q1W model)
☆ 5 timesP4Inverter compressor drive error

 

Error Code: P4

Malfunction decision conditions: An abnormal inverter compressor drive is detected by a special detection circuit, including communication signal detection, voltage detection, compressor rotation speed signal detection and so on.

Error Code: P2

Malfunction decision conditions: If the sampling voltage is not 5V, the LED will display the failure.

Error Code: P1

Malfunction decision conditions: An abnormal voltage rise or drop is detected by checking the specified voltage detection circuit.

Error Code: P0

Malfunction decision conditions: When the voltage signal that IPM send to compressor drive chip is abnormal, the display LED will show “P0” and AC will turn off.

Error Code: EC

Malfunction decision conditions: Define the evaporator coil temp.T2 of the compressor just starts running as Tcool.

Error Code: E5

Malfunction decision conditions: If the sampling voltage is lower than 0.06V or higher than 4.94V, the LED will display the failure.

Error Code: E3

Malfunction decision conditions: When indoor fan speed keeps too low (300RPM) for certain time, the unit will stop and the LED will display the failure.

Error Code: E2

Malfunction decision conditions: When PCB does not receive zero crossing signal feedback for 4 minutes or the zero crossing signal time interval is abnormal.

Error Code: E1

Malfunction decision conditions: Indoor unit does not receive the feedback from outdoor unit during 110 seconds and this condition happens four times continuously.

Error Code: E0/F4

Malfunction decision conditions: Indoor or outdoor PCB main chip does not receive feedback from EEPROM chip.

DuctlessAire Air Conditioner Unit Parts
DuctlessAire Air Conditioner Unit Parts

Comments

Popular posts from this blog

Rittal Air Conditioner Error Codes

  System messages are shown on the display screen of the Comfort controller via the displays A1 to A20 and E0. Rittal Air Conditioner Error Codes Error Codes System message Possible cause A1 Enclosure door open Door open or door limit switch incorrectly positioned A2 Internal temperature of enclosure too high Cooling capacity inadequate/unit undersized. Error as a consequence of messages A03 to A17. A3 Filter monitoring Filter mat soiled A4 Ambient temperature too high/too low Ambient temperature outside of admissible operating range (+10°C to +60°C) A5 Icing hazard Operational display in case of icing hazard. A6 PSAH pressure-operated switch Ambient temperature too high A7 Evaporator coil Lack of coolant; sensor in front of or behind condenser defective. A8 Condensate warning Condensate discharge kinked or blocked A9 Condenser fan blocked or defective Blocked or defective A10 Evaporator fan blocked or defective Blocked or defective A11 Compressor Compressor overloaded A12 Condense...

Samsung DVM-S VRF Error Codes

  DVM Digital Variable Multi VRF Systems Error Codes Samsung DVM VRF Error Codes Error code related indoor unit: Error Codes Explanation E-101 Indoor unit communication error. Indoor unit can not receive any data from outdoor unit. E-102 Communication error between indoor unit and outdoor unit. Displayed in indoor unit. E-108 Error due to repeated address setting (When 2 or more devices has same address within the network) E-121 Error on indoor temperature sensor of indoor unit (Short or Open) E-122 Error on EVA IN sensor of indoor unit (Short or Open) E-123 Error on EVA OUT sensor of indoor unit (Short or Open) E-128 EVA IN temperature sensor of indoor unit is detached from EVA IN pipe E-129 EVA OUT temperature sensor of indoor unit is detached from EVA OUT pipe E-130 Heat exchanger in/out sensors of indoor unit are detached E-135 RPM feedback error of indoor unit's cleaning fan E-149 Error due to AHU master indoor unit sensor setting. E-151 Error due to opened EEV of indoor unit ...

Panasonic VRF AC Error Codes and Troubleshooting

  Indoor unit is detecting error signal from remote controller (and system controller). Panasonic Mini VRF AC Error Codes and Troubleshooting Error Codes Meaning E01 Error in receiving serial communication signal. E02 Error in transmitting serial communication signal. E03 Indoor unit is detecting error signal from remote controller. E04 Error in receiving serial communication signal. When turning on the power supply, the number of connected indoor units does not correspond to the number set. E06 Error of the outdoor unit in receiving serial communication signal from the indoor unit. E08 Indoor unit address setting is duplicated. E09 Remote controller address connector. E12 Starting auto address setting is prohibited. This alarm message shows that the auto address connector CN-A.ADD is shorted while other RC line is executing auto address operation. E15 Error in auto address setting. E16 Error in auto address setting. E20 No indoor unit is connected during auto address setting. E24 ...