Derby Air Conditioner Error Codes
Error CodesLed Status
E0EEPROM parameter error
E1Indoor / outdoor units communication protection
E2Zero-crossing signal error
E3Fan speed out of control
E5Open or short circuit of outdoor temperature sensor (T4)
E6Open or short circuit of room (T1) or evaporator temperature sensor (T2)
P0Outdoor PCB protection
P1Over voltage or too low voltage protection
P2Temperature protection of compressor top.
P4Inverter compressor drive error

Note: E4 & P3: Reserved function

Diagnosis and Solution

E0 (EEPROM parameter error) error diagnosis and solution

Circuit or software error on indoor PCB ⇒ Replace indoor PCB

E1 (indoor / outdoor units communication protection) error diagnosis and solution

E2 (zero-crossing signal error) diagnosis and solution

E3 (indoor fan speed out of control) diagnosis and solution

Troubleshooting

*Unit does not star:

  • Power cut. Wait for power to be restored.
  • Unit may have become unplugged. Check that plug is securely in wall receptacle.
  • Fuse may have blown. Replace the fuse.
  • Battery in Remote controller may have been exhausted. Replace the battery.
  • The time you have set with timer is incorrect. Wait or cancel timer setting.

*Unit not cooling or heating (Cooling/ heating models only) room very well while air flowing out from the air condtioner:

  • Inappropriate temperature setting. Set temperature correctly.
  • Air filter is blocked. Clean the air filter.
  • Doors or Windows are open. Close the doors or windows.
  • Air inlet or outlet of indoor or outdoor unit has been blocked. Clear obstructions away first, then restart the unit.
  • Compressor 3 minutes protection has been activated. Wait.

If the trouble has not been corrected, please contact a local dealer or the nearest customer service center. Be sure to inform them of the detailed malfunctions and unit model.

Derby AC Self Diagnostic Failure Indications
Derby AC Self Diagnostic Failure Indications

 

Derby Air Conditioner Manual PDF-1

Derby Air Conditioner Manual PDF-2

Derby Air Conditioner Manual PDF-3

Comments

Popular posts from this blog

Rittal Air Conditioner Error Codes

  System messages are shown on the display screen of the Comfort controller via the displays A1 to A20 and E0. Rittal Air Conditioner Error Codes Error Codes System message Possible cause A1 Enclosure door open Door open or door limit switch incorrectly positioned A2 Internal temperature of enclosure too high Cooling capacity inadequate/unit undersized. Error as a consequence of messages A03 to A17. A3 Filter monitoring Filter mat soiled A4 Ambient temperature too high/too low Ambient temperature outside of admissible operating range (+10°C to +60°C) A5 Icing hazard Operational display in case of icing hazard. A6 PSAH pressure-operated switch Ambient temperature too high A7 Evaporator coil Lack of coolant; sensor in front of or behind condenser defective. A8 Condensate warning Condensate discharge kinked or blocked A9 Condenser fan blocked or defective Blocked or defective A10 Evaporator fan blocked or defective Blocked or defective A11 Compressor Compressor overloaded A12 Condense...

Samsung DVM-S VRF Error Codes

  DVM Digital Variable Multi VRF Systems Error Codes Samsung DVM VRF Error Codes Error code related indoor unit: Error Codes Explanation E-101 Indoor unit communication error. Indoor unit can not receive any data from outdoor unit. E-102 Communication error between indoor unit and outdoor unit. Displayed in indoor unit. E-108 Error due to repeated address setting (When 2 or more devices has same address within the network) E-121 Error on indoor temperature sensor of indoor unit (Short or Open) E-122 Error on EVA IN sensor of indoor unit (Short or Open) E-123 Error on EVA OUT sensor of indoor unit (Short or Open) E-128 EVA IN temperature sensor of indoor unit is detached from EVA IN pipe E-129 EVA OUT temperature sensor of indoor unit is detached from EVA OUT pipe E-130 Heat exchanger in/out sensors of indoor unit are detached E-135 RPM feedback error of indoor unit's cleaning fan E-149 Error due to AHU master indoor unit sensor setting. E-151 Error due to opened EEV of indoor unit ...

Panasonic VRF AC Error Codes and Troubleshooting

  Indoor unit is detecting error signal from remote controller (and system controller). Panasonic Mini VRF AC Error Codes and Troubleshooting Error Codes Meaning E01 Error in receiving serial communication signal. E02 Error in transmitting serial communication signal. E03 Indoor unit is detecting error signal from remote controller. E04 Error in receiving serial communication signal. When turning on the power supply, the number of connected indoor units does not correspond to the number set. E06 Error of the outdoor unit in receiving serial communication signal from the indoor unit. E08 Indoor unit address setting is duplicated. E09 Remote controller address connector. E12 Starting auto address setting is prohibited. This alarm message shows that the auto address connector CN-A.ADD is shorted while other RC line is executing auto address operation. E15 Error in auto address setting. E16 Error in auto address setting. E20 No indoor unit is connected during auto address setting. E24 ...