Delonghi Portable AC Error Codes and Troubleshooting
Delonghi Portable AC Error Codes and Troubleshooting

Self-Diagnosis:

Error CodesWhat Should I Do
LELow Temperature (frost prevention). The appliance is fitted with a frost protection device to avoid excessive formation of ice. The appliance starts up again automatically when the defrosting process is completed.
HLHigh Level (internal tray full). Empty the internal safety tray following the instructions in the section “End of season operations”. If it reoccurs in cooling mode, contact your local authorised customer services. In heating mode: empty the internal tray.
CFChange filter. When this message is displayed, the water filter needs replacing as described in the section: “Replacing the limescale filter”.
PFProbe Failure (sensor damaged). If this is displayed, contact your local authorised service centre.
F1Failure 1. This message could appear if the water filter is particularly clogged. See section: “Replacing the limescale filter”. If the filter has been replaced recently, contact your local authorised service centre.
LoLow Temperature - Room temperature is too low.
H1High Temperature - Room temperature is too high.
E1Probe Failure ( Sensor Damaged).

The appliance has a self diagnosis system to identify a number of malfunctions. Error messages are displayed on the appliance display.

Delonghi Portable Air Conditioner Error Codes
Delonghi Portable Air Conditioner Error Codes – LE, HL, CF, PF and F1

Delonghi Portable AC Troubleshooting

Problem: The air conditioner does not come on

Cause:

  1. there is no current
  2. it is not plugged into the mains
  3. the internal safety device has tripped

Solution:

  1. wait
  2. plug into the mains
  3. call the Service Centre

Problem: The air conditioner works for a short time only

Cause:

  1. there are bends or kinks in the air exhaust hose
  2. something is preventing the air from being discharged

Solution:

  1. position the air hose correctly, keeping it as short and free of curves as possible to avoid bottlenecks.
  2. check and remove any obstacles obstructing air discharge

Problem: The air conditioner works, but does not cool the room

Cause:

  1. windows, doors and/or curtains open
  2. there are heat sources in the room (oven, hairdryer, etc)
  3. the air exhaust hose is detached from the appliance
  4. dust filters clogged

Solution:

  1. close doors, windows and curtains, bearing in mind the “tips for correct use” given above
  2. eliminate the heat sources
  3. fit the air exhaust hose in the housing at the back of the appliance
  4. clean or replace the filters as described above

Problem: During operation, there is an unpleasant smell in the room

Cause: dust filter and (when present) electrostatic filter clogged

Solution: clean the filters as described above

Problem: The air conditioner does not operate for about three minutes after restarting it

Cause: the internal compressor safety device prevents the appliance from being restarted until three minutes have elapsed since it was last turned off.

Solution: wait. This delay is part of normal operation.

Problem: The symbol and one of the following messages LT / HL/Cf/PF / FI appears on the appliance display:

Cause: The appliance has a self diagnosis system to identify a number of malfunctions.

Solution: See the SELF-DIAGNOSIS chapter.

Delonghi Portable Air Conditioner Error Codes1
Delonghi Portable Air Conditioner Error Codes

“CF” is displayed when the limescale filter needs replacing. The efficacy of the filter depends on water hardness. It should, however, be replaced every five years.

If the remote control unit is replaced or discarded, the batteries must be removed and disposed of in accordance with current legislation as they are harmful to the environment. Do not mix old and new batteries. Do not mix alka line, standard (carbon-zinc) or rechargeable (nickel-cadmium) batteries. Do not dispose of batteries in fire. Batteries may explode or leak.

Delonghi Description of The Remote Control
Delonghi 4 in 1 Portable AC Display Panel
Delonghi 4 in 1 Portable AC Display Panel
Delonghi Portable AC Display Panel 2
Delonghi Portable AC Display Panel 2

Delonghi Portable A.C  Manual PDF

Delonghi 4 in 1 AC Manual PDF

De’longhi Air Conditioner Manual AN140EKF PDF


Comments

Popular posts from this blog

Rittal Air Conditioner Error Codes

  System messages are shown on the display screen of the Comfort controller via the displays A1 to A20 and E0. Rittal Air Conditioner Error Codes Error Codes System message Possible cause A1 Enclosure door open Door open or door limit switch incorrectly positioned A2 Internal temperature of enclosure too high Cooling capacity inadequate/unit undersized. Error as a consequence of messages A03 to A17. A3 Filter monitoring Filter mat soiled A4 Ambient temperature too high/too low Ambient temperature outside of admissible operating range (+10°C to +60°C) A5 Icing hazard Operational display in case of icing hazard. A6 PSAH pressure-operated switch Ambient temperature too high A7 Evaporator coil Lack of coolant; sensor in front of or behind condenser defective. A8 Condensate warning Condensate discharge kinked or blocked A9 Condenser fan blocked or defective Blocked or defective A10 Evaporator fan blocked or defective Blocked or defective A11 Compressor Compressor overloaded A12 Condense...

Panasonic VRF AC Error Codes and Troubleshooting

  Indoor unit is detecting error signal from remote controller (and system controller). Panasonic Mini VRF AC Error Codes and Troubleshooting Error Codes Meaning E01 Error in receiving serial communication signal. E02 Error in transmitting serial communication signal. E03 Indoor unit is detecting error signal from remote controller. E04 Error in receiving serial communication signal. When turning on the power supply, the number of connected indoor units does not correspond to the number set. E06 Error of the outdoor unit in receiving serial communication signal from the indoor unit. E08 Indoor unit address setting is duplicated. E09 Remote controller address connector. E12 Starting auto address setting is prohibited. This alarm message shows that the auto address connector CN-A.ADD is shorted while other RC line is executing auto address operation. E15 Error in auto address setting. E16 Error in auto address setting. E20 No indoor unit is connected during auto address setting. E24 ...

Vestel AC Error Codes and Troubleshooting

  Error Messages   are displayed, respectively by first the   Er   icon and then the special code (01, 02, …, 20, etc.) of the failure. In that case, do nothing to the air conditioner and contact with the Authorised Service.   Er11   and   Er13   are not error messages. If you see these messages, apply the steps under the following protection messages section. Vestel AC Error Code and Troubleshooting Error Codes Cause dF The icing on the outdoor unit is being defrosted. After the defrosting operation is accomplished, your air conditioner will continue to operate in the heating mode, the product should not be turned off while this mode is enabled. RE Make the arc control for your electrical wiring, if the problem is not fixed call for the service. If the problem comes out very frequently, contact with the authorised service. Sr In case of certain failures, in order to not to spoil you comfort, your air conditioner continues to operate despite the f...