Danby Portable AC Error Codes and Troubleshooting

 Occasionally, a problem may arise that is minor in nature, and a service call may not be necessary. Use this troubleshooting guide for a possible solution.

Danby Portable AC Error Codes and Troubleshooting
Danby Portable AC Error Codes and Troubleshooting
Error CodesProblem
E1Error with the coils temperature sensor.
E2Error with the indoor temperature sensor.
E4Frost protection: the temperature of the coil is too low and the A/C shuts down to prevent excess frost build-up. When the temperature increases to 8°C (46.4°F), the  protective setting is released and the previous setting is applied.
FtTank is full - Connect the drain hose and drain the collected water away. If error repeats, call for service.
P1Bottom tray is full - Connect the drain hose and drain the collected water away. If error repeats, call for service.
LtLow Temperature. The unit will defrost. The appliance will start again once defrosting is complete
PFProbe failure, call for service
Danby Portable Air Conditioner Troubleshooting
Danby Portable Air Conditioner Troubleshooting

Danby Portable Air Conditioner Troubleshooting

Problem: Unit does not start when pressing on/off button

Possible Cause:

  1. P1 appears in the display window
  2. Room temperature is lower than the set temperature. (Cooling mode)

Solution:

  1. Drain the water in the bottom tray.
  2. Reset the temperature.

Problem: Not cool enough

Possible Cause:

  1. The windows or doors in the room are not closed.
  2. There are heat sources inside the room.
  3. Exhaust air duct is not connected or blocked.
  4. Temperature setting is too high.
  5. Air filter is blocked by dust.

Solution:

  1. Make sure all the windows and doors are closed.
  2. Remove the heat sources if possible.
  3. Connect the duct and make sure it can function properly.
  4. Decrease the set temperature.
  5. Clean the air filter.

Problem: Noisy or vibration

Possible Cause: The ground is not level or not flat enough.

Solution: Place the unit on a flat, level ground if possible.

Problem: Gurgling sound

Possible Cause: The sound comes from the flowing of the refrigerant inside the air conditioner

Solution: It is normal

Problem: Power shut off at Heating mode

Possible Cause: The automatic over heat protection function. When the temperature at the air outlet exceeds 70°C/158°F, the device wi ll stop.

Solution: Switch on again after the unit has cooled down.

Danby Portable AC Remote Control
Danby Portable AC Remote Control

WARNING

Be sure the electrical service is adequate for the model you have chosen. This information can be found on the serial plate, which is located on the side of the cabinet and behind the grille.

• Be sure the air conditioner is properly grounded. To minimize shock and fire hazards, proper grounding is important. The power cord is equipped with a three-prong grounding plug for protection against shock hazards.

• Your air conditioner must be used in a properly grounded wall receptacle. If the wall receptacle you intend to use is not adequately grounded or protected by a time delay fuse or circuit breaker, have a qualified electrician install the proper receptacle.

• Ensure the receptacle is accessible after the unit installation.

Danby Portable Air Conditioner Parts
Danby Portable Air Conditioner Parts

How to Fix P1 Error?

When the water level of the bottom tray reaches a predetermined level, the unit beeps 8 times, the digital display area shows P1. At this time the air conditioning/dehumidification process will immediately stop. However, the fan motor will continue to operate (this is normal). Carefully move the unit to a drain location, remove the bottom drain plug and let the water drain away (Fig.24). Restart the machine until the P1 symbol disappears. If the error repeats, call for service.

During dehumidifying modes, remove the drain plug from the back of the unit, install the drain connector (5/8” universal female connecter) with 3/4” hose (locally purchased). For the models without a drain connector, just attach the drain hose to the hole. Place the open end of the hose directly over the drain area in your basement floor. Please refer to Fig.22 & 23.

NOTE: When operating or draining water always protect carpeting or floors from possible water spillage.

Danby Portable Air Conditioner Water Drainage
Danby Portable Air Conditioner Water Drainage

Air Filter

Clean the air filter at least once every two weeks to prevent inferior fan operation because of dust.

Removal: This unit has three filters. Take the upper filter out along the arrow direction (Fig.25), then take the filter down. Remove the lower filter and the side filter by loosening the screws, taking out the filters as shown in Fig.25.

Cleaning: Wash the air filter by immersing it gently in warm water (about 40°C / 104 °F) with a neutral detergent. Rinse the filter and dry it in a shady place.

Mounting: Install the upper air filter after cleaning ,then insert the side filter into the unit and install the lower filter by using the screws (see Fig.26).

Danby Portable Air Conditioner Control Panel
Danby Portable Air Conditioner Control Panel

Danby Portable Air Conditioner Manual

Comments

Popular posts from this blog

Rittal Air Conditioner Error Codes

  System messages are shown on the display screen of the Comfort controller via the displays A1 to A20 and E0. Rittal Air Conditioner Error Codes Error Codes System message Possible cause A1 Enclosure door open Door open or door limit switch incorrectly positioned A2 Internal temperature of enclosure too high Cooling capacity inadequate/unit undersized. Error as a consequence of messages A03 to A17. A3 Filter monitoring Filter mat soiled A4 Ambient temperature too high/too low Ambient temperature outside of admissible operating range (+10°C to +60°C) A5 Icing hazard Operational display in case of icing hazard. A6 PSAH pressure-operated switch Ambient temperature too high A7 Evaporator coil Lack of coolant; sensor in front of or behind condenser defective. A8 Condensate warning Condensate discharge kinked or blocked A9 Condenser fan blocked or defective Blocked or defective A10 Evaporator fan blocked or defective Blocked or defective A11 Compressor Compressor overloaded A12 Condense...

Samsung DVM-S VRF Error Codes

  DVM Digital Variable Multi VRF Systems Error Codes Samsung DVM VRF Error Codes Error code related indoor unit: Error Codes Explanation E-101 Indoor unit communication error. Indoor unit can not receive any data from outdoor unit. E-102 Communication error between indoor unit and outdoor unit. Displayed in indoor unit. E-108 Error due to repeated address setting (When 2 or more devices has same address within the network) E-121 Error on indoor temperature sensor of indoor unit (Short or Open) E-122 Error on EVA IN sensor of indoor unit (Short or Open) E-123 Error on EVA OUT sensor of indoor unit (Short or Open) E-128 EVA IN temperature sensor of indoor unit is detached from EVA IN pipe E-129 EVA OUT temperature sensor of indoor unit is detached from EVA OUT pipe E-130 Heat exchanger in/out sensors of indoor unit are detached E-135 RPM feedback error of indoor unit's cleaning fan E-149 Error due to AHU master indoor unit sensor setting. E-151 Error due to opened EEV of indoor unit ...

Panasonic VRF AC Error Codes and Troubleshooting

  Indoor unit is detecting error signal from remote controller (and system controller). Panasonic Mini VRF AC Error Codes and Troubleshooting Error Codes Meaning E01 Error in receiving serial communication signal. E02 Error in transmitting serial communication signal. E03 Indoor unit is detecting error signal from remote controller. E04 Error in receiving serial communication signal. When turning on the power supply, the number of connected indoor units does not correspond to the number set. E06 Error of the outdoor unit in receiving serial communication signal from the indoor unit. E08 Indoor unit address setting is duplicated. E09 Remote controller address connector. E12 Starting auto address setting is prohibited. This alarm message shows that the auto address connector CN-A.ADD is shorted while other RC line is executing auto address operation. E15 Error in auto address setting. E16 Error in auto address setting. E20 No indoor unit is connected during auto address setting. E24 ...