Daihatsu Air Conditioner Error Codes

 

Daihatsu Air Conditioner Error Codes
Daihatsu Air Conditioner Error Codes

Daihatsu Inverter Air Conditioner Error Codes; When air conditioner status is abnormal, temperature indictor on indoor unit will blink to display corresponding error code. Please refer to below list for identific ation of error code.

Digital LED CodeFailure Type-LED Code-Function Indicator (flash)
E0Indoor and outdoor communication failure. RUN, TIMER – both winking.
ECOutdoor communication failure. RUN TIMER – both winking.
E1Indoor room temperature sensor (IRT). RUN-1 time/8s.
E2Indoor coil temperature sensor (IPT). RUN-2 times /8s.
E3Outdoor coil temperature sensor (OPT). RUN-3 times /8s.
E4System abnormity. RUN-4 times /8s.
E5Model configuration wrong. RUN-5 times /8s.
E6Indoor fan motor fault. RUN-6 times /8s.
E7Outdoor temperature sensor. RUN-7 times /8s.
E8Exhaust temp. sensor. RUN-8 times /8s.
E9IPM drive and module fault. RUN-9 times /8s.
EFOutdoor fan motor fault (DC motor). RUN-10 times /8s.
EACurrent sensor fault. RUN-11 times /8s.
EEIndoor unit EEPROM fault. RUN-12 times /8s.
EPTemp. switch fault ( on top of the compressor). RUN-13 times /8s.
EUVoltage sensor fault. RUN-14 times /8s.
P1Overvoltage /lower voltage protection. RUN: Blink; TIMER: 1 blink /8 sec.
P2Overcurrent protection. RUN: Blink; TIMER: 2 blink /8 sec.
P4Exhaust over temperature protection. RUN: Blink; TIMER: 4 blink /8 sec.
P5Too cool protection in cooling mode. RUN: Bright; TIMER: 5 blink /8 sec.
P6Overheat protection in cooling mode. RUN: Bright; TIMER: 6 blink /8 sec.
P7Overheat protection in heating mode. RUN: Bright; TIMER: 7 blink /8 sec.
P8Outdoor over temperature / lower temperature protection. RUN: Bright; TIMER: 8 blink /8 sec.
P9Drive protection (software control ). RUN: Blink; TIMER: 9 blink /8 sec.
P0Module protection (hardware control). RUN: Blink; TIMER: 10 blink /8 sec.
C5Connector jumper malfunction. Check if the connector jumper contacts the properly. If replace the PCB, please take off the old for the new PCB.
H6PC motor (indoor fan) can’t run. Feedback terminal of PG motor hasn’t been connected firmly. The control end of PG motor hasn’t been connected firmly
U8Malfunction of zero cross detection circuit for PG motor (indoor fan). Control panel has been damaged.
daihatsu air conditioner remote controller
Daihatsu Air Conditioner Remote Controller

Outdoor failure display

There is a LED on outdoor power board, it blinks 1s ON and 1s OFF while compressor standby and it always light (ON) while compressor running; If there is failure happened on ODU, The indicator (LED) alerts the fault in a cycle as such that it is bright for 0.5 seconds, dark for 0.5 seconds, blinks “n” times and then dark for 3 seconds. For details as table below:

Display on outdoor power source board:


blink time (n)Failure
1IPM protection
2Over voltage /lower voltage
3Overcurrent
4Exhaust over temperature protection
5Outdoor coil over temperature protection
6Drive fault and protection (V1ˈVP1)
7Communication fault with indoor unit
8Compressor overheat fault (compressor top switch)
9Short-circuit / open-circuit fault of outdoor temperature sensor
10Short circuit / open-circuit fault of outdoor heat exchanger temperature sensor
11Short-circuit / open-circuit fault of exhaust temperature sensor
12Voltage sensor fault
13Current sensor fault
14IPM fault
15Communication fault between power source board and IPM
16No feedback from DC fan motor(outdoor unit)
17Defrost state

Daihatsu Air Conditioner Troubleshooting

Please check below items before asking for maintenance. If the malfunction still can’t be eliminated, please contact local dealer or qualified professionals.

TroubleSolution
Indoor unit can’t receive remote controller’s signal or remote controller has no action.Whether it’s interfered severely (such as static electricity,stable voltage)? Pull out the plug. Reinsert the plug after about 3 min, and then turn on the unit again.
Whether remote controller is within the signal receiving range? Signal receiving range is 8m.
Whether there are obstacles? Remove obstacles.
Whether remote controller is pointing at the receiving window? Select proper angle and point the remote controller at the receiving window on indoor unit.
Is sensitivity of remote controller low; fuzzy display and no display? Check the batteries. If the power of batteries is too low, please replace them.
No display when operating remote controller? Check whether remote controller appears to be damaged. If yes, replace it.
Fluorescent lamp in room? Take the remote controller close to indoor unit. Turn off the fluoresent lamp and then try it again.
No air emitted from indoor unitAir inlet or air outlet of indoor unit is blocked? Eliminate obstacles.
Under heating mode, indoor temperature is reached to set temperature? After reaching to set temperature, indoor unit will stop blowing out air.
Heating mode is turned on just now? In order to prevent blowing out cold air, indoor unit will be started after delaying for several minutes, which is a normal phenomenon.
Air conditioner can’t operatePower failure? Wait until power recovery.
Is plug loose? Reinsert the plug.
Air switch trips off or fuse is burnt out? Ask professional to replace air switch or fuse.
Wiring has malfunction? Ask professional to replace it.
Unit has restarted immediately after stopping operation? Wait for 3 min, and then turn on the unit again.
Whether the function setting for remote controller is correct? Reset the function.
Mist is emitted from indoor unit’s air outletIndoor temperature and humidity is high? Because indoor air is cooled rapidly. After a while, indoor temperature and humidity will be decrease and mist will disappear.
Odours are emittedWhether there’s odour source, such as furniture and cigarette, etc. Eliminate the odour source. Clean the filter.
Air conditioner operates normally suddenlyWhether there’s interference, such as thunder, wireless devices, etc. Disconnect power, put back power, and then turn on the unit again.
Outdoor unit has vaporHeating mode is turned on? During defrosting under heating mode, it may generate vapor, which is a normal phenomenon.
“Water flowing” noiseAir conditioner is turned on or turned off just now? The noise is the sound of refrigerant flowing inside the unit, which is a normal phenomenon.
Cracking noiseAir conditioner is turned on or turned off just now? This is the sound of friction caused by expansion and/or contraction of panel or other parts due to the change of temperature.

Introduction for buttons on remote controller

Introduction for buttons on remote controller
Introduction for buttons on remote controller

Comments

Popular posts from this blog

Rittal Air Conditioner Error Codes

  System messages are shown on the display screen of the Comfort controller via the displays A1 to A20 and E0. Rittal Air Conditioner Error Codes Error Codes System message Possible cause A1 Enclosure door open Door open or door limit switch incorrectly positioned A2 Internal temperature of enclosure too high Cooling capacity inadequate/unit undersized. Error as a consequence of messages A03 to A17. A3 Filter monitoring Filter mat soiled A4 Ambient temperature too high/too low Ambient temperature outside of admissible operating range (+10°C to +60°C) A5 Icing hazard Operational display in case of icing hazard. A6 PSAH pressure-operated switch Ambient temperature too high A7 Evaporator coil Lack of coolant; sensor in front of or behind condenser defective. A8 Condensate warning Condensate discharge kinked or blocked A9 Condenser fan blocked or defective Blocked or defective A10 Evaporator fan blocked or defective Blocked or defective A11 Compressor Compressor overloaded A12 Condense...

Panasonic VRF AC Error Codes and Troubleshooting

  Indoor unit is detecting error signal from remote controller (and system controller). Panasonic Mini VRF AC Error Codes and Troubleshooting Error Codes Meaning E01 Error in receiving serial communication signal. E02 Error in transmitting serial communication signal. E03 Indoor unit is detecting error signal from remote controller. E04 Error in receiving serial communication signal. When turning on the power supply, the number of connected indoor units does not correspond to the number set. E06 Error of the outdoor unit in receiving serial communication signal from the indoor unit. E08 Indoor unit address setting is duplicated. E09 Remote controller address connector. E12 Starting auto address setting is prohibited. This alarm message shows that the auto address connector CN-A.ADD is shorted while other RC line is executing auto address operation. E15 Error in auto address setting. E16 Error in auto address setting. E20 No indoor unit is connected during auto address setting. E24 ...

Vestel AC Error Codes and Troubleshooting

  Error Messages   are displayed, respectively by first the   Er   icon and then the special code (01, 02, …, 20, etc.) of the failure. In that case, do nothing to the air conditioner and contact with the Authorised Service.   Er11   and   Er13   are not error messages. If you see these messages, apply the steps under the following protection messages section. Vestel AC Error Code and Troubleshooting Error Codes Cause dF The icing on the outdoor unit is being defrosted. After the defrosting operation is accomplished, your air conditioner will continue to operate in the heating mode, the product should not be turned off while this mode is enabled. RE Make the arc control for your electrical wiring, if the problem is not fixed call for the service. If the problem comes out very frequently, contact with the authorised service. Sr In case of certain failures, in order to not to spoil you comfort, your air conditioner continues to operate despite the f...