Skip to main content

Daewoo AC Error Codes and Troubleshooting

 The following table shows the fault protections.

Daewoo Air Conditioner Error Codes and Troubleshooting
Daewoo Air Conditioner Error Codes and Troubleshooting
Error CodesSolution
Indoor unitLED display function
E0EEPROM error
E1Indoor and outdoor communication error
E2Zero-crossing examination error
E3Fan speed beyond control
E5Outdoor units temp. sensor or connector of temp. sensor is defective
E6Indoor units temp. sensor or connector of temp. sensor is defective
P0Inverter module protection
P1Outdoor voltage protection
P2Compressor top protection against temperature
P3Compressor current protection
P5Outdoor low temp. protection
Outdoor unitLED display function
E0EEPROM error
E1No 1 Indoor units pipe temp. sensor or connector of pipe temp. sensor is defective
E2No 2 Indoor units pipe temp. sensor or connector of pipe temp. sensor is defective
E3No 3 Indoor units pipe temp. sensor or connector of pipe temp. sensor is defective
E4Outdoor temp. sensor or connector of temp. sensor is defective
E5Compressor voltage protection
E6No 4 Indoor units pipe temp. sensor or connector of pipe temp. sensor is defective
E7Indoor and outdoor communication error
P0Compressor top protection against temperature
P1High pressure protection
P2Low pressure protection
P3Compressor current protection
P4Inverter module protection
P5Outdoor low temp. protection
P6Condenser high-temperature protection

Troubleshooting

Before requesting service, please refer to the chart below for possible solutions:

Symptoms: No power

Possible Cause:

  1. Power failure.
  2. Line voltage too low.
  3. Unit is unplugged or not completely plugged in.
  4. Unit is off.
  5. Batteries in remote are weak or dead.
  6. EMERGENCY/REMOTE switch is not set to REMOTE.

Possible Solutions:

  1. Restore the power.
  2. Contact electrician to install new outlet.
  3. Insert plug all the way.
  4. Turn unit on.
  5. Replace remote’s batteries.
  6. Slide EMERGENCY/REMOTE to REMOTE.

Symptoms: The compressor does not turn on. (no cool air)

Possible Cause:

  1. When the unit is first plugged in and turned on, the compressor will delay turn on for 3 minutes.
  2. If the unit is turned off and then immediately back on, the compressor will delay for 3 minutes.
  3. The air filter(s) is dirty or clogged.
  4. Unit is located near a heat source (heater, stove, etc.)
  5. A door or window is open.
  6. There is an obstacle in front of intake or indoor unit.
  7. Thermostat is set too high.

Possible Solutions:

  1. Wait 3 minutes for the unit to operate.
  2. Wait 3 minutes for the unit to operate.
  3. Clean or replace filter(s).
  4. When locating unit for the first time,make sure it is in a desirable location.
  5. Shut door or window.
  6. Remove obstacle.
  7. Set thermostat lower.

Symptoms: Strange sounds occur

Possible Cause: During operation, especially after turning it on or off, refrigerant flows inside the unit.

Possible Solutions: This is normal.

Symptoms: Strange smells occur.

Possible Cause: The fan is bringing out the smells of the carpet, walls, etc.

Possible Solutions: The smell should go away shortly.

Symptoms: No remote operation.

Possible Cause:

  1. Batteries are weak, dead or inserted improperly.
  2. Remote is out of range.
  3. Remote not aimed at sensor.
  4. There is an obstruction between unit and remote.

Possible Solutions:

  1. Replace batteries.
  2. Move closer to unit.
  3. Aim remote at sensor.
  4. Remove obstruction.

Self-Diagnostic Function

Error CODE- Display- Check point
Error CODE- Display- Check point
Failure phenomenon- Operation lamp -Timer lamp -Fan lamp
Failure phenomenon- Operation lamp -Timer lamp -Fan lamp

Indoor fan does not operate at all (E6).

How to fix E6
How to fix E6

Product does not operate at all.

Product does not operate at all
Product does not operate at all

Daewoo Air Conditioner Remote Control

Daewoo Air Conditioner Remote Control
Daewoo Air Conditioner Remote Control

 

Daewoo Air Conditioner Service Manual PDF

Comments

Popular posts from this blog

Rittal Air Conditioner Error Codes

  System messages are shown on the display screen of the Comfort controller via the displays A1 to A20 and E0. Rittal Air Conditioner Error Codes Error Codes System message Possible cause A1 Enclosure door open Door open or door limit switch incorrectly positioned A2 Internal temperature of enclosure too high Cooling capacity inadequate/unit undersized. Error as a consequence of messages A03 to A17. A3 Filter monitoring Filter mat soiled A4 Ambient temperature too high/too low Ambient temperature outside of admissible operating range (+10°C to +60°C) A5 Icing hazard Operational display in case of icing hazard. A6 PSAH pressure-operated switch Ambient temperature too high A7 Evaporator coil Lack of coolant; sensor in front of or behind condenser defective. A8 Condensate warning Condensate discharge kinked or blocked A9 Condenser fan blocked or defective Blocked or defective A10 Evaporator fan blocked or defective Blocked or defective A11 Compressor Compressor overloaded A12 Condense...

Panasonic VRF AC Error Codes and Troubleshooting

  Indoor unit is detecting error signal from remote controller (and system controller). Panasonic Mini VRF AC Error Codes and Troubleshooting Error Codes Meaning E01 Error in receiving serial communication signal. E02 Error in transmitting serial communication signal. E03 Indoor unit is detecting error signal from remote controller. E04 Error in receiving serial communication signal. When turning on the power supply, the number of connected indoor units does not correspond to the number set. E06 Error of the outdoor unit in receiving serial communication signal from the indoor unit. E08 Indoor unit address setting is duplicated. E09 Remote controller address connector. E12 Starting auto address setting is prohibited. This alarm message shows that the auto address connector CN-A.ADD is shorted while other RC line is executing auto address operation. E15 Error in auto address setting. E16 Error in auto address setting. E20 No indoor unit is connected during auto address setting. E24 ...

Vestel AC Error Codes and Troubleshooting

  Error Messages   are displayed, respectively by first the   Er   icon and then the special code (01, 02, …, 20, etc.) of the failure. In that case, do nothing to the air conditioner and contact with the Authorised Service.   Er11   and   Er13   are not error messages. If you see these messages, apply the steps under the following protection messages section. Vestel AC Error Code and Troubleshooting Error Codes Cause dF The icing on the outdoor unit is being defrosted. After the defrosting operation is accomplished, your air conditioner will continue to operate in the heating mode, the product should not be turned off while this mode is enabled. RE Make the arc control for your electrical wiring, if the problem is not fixed call for the service. If the problem comes out very frequently, contact with the authorised service. Sr In case of certain failures, in order to not to spoil you comfort, your air conditioner continues to operate despite the f...