Comfort Aire AC Error Codes

 Some issues can be resolved without any maintenance to the unit, check the chart below to see if there is a suggested solution to the problem before calling for service.

Comfortaire AC Error Codes and Troubleshooting
Comfortaire AC Error Codes and Troubleshooting

 

Glossary of Error Codes and Their Meanings:

Error CodesMeaning
E1High Pressure Protection
E2Shutdown for Whole Unit AntiFreeze Protection
E3Low Pressure Protection
E4High Discharge Temp Protection
E6Communication Error
E9Indoor Unit Water Full Error
FoRefrigerant Recovery Mode
F3Outdoor Ambient Temp Sensor Error
F4Outdoor Mid-Coil Temp Sensor Error
F5Outdoor Discharge Air Temp Sensor Error
F7Oil Return for Cooling
H1Forced Defrosting
H2Oil Return for Heating or Defrosting
H3Compressor Overheat Protection
H5IPM Protection
H7Motor Desynchronizing
HcPFC Error
LcStartup Failure
LADC Fan motor Error
LdPhase Loss
LECompressor Stalling
LFOver-Speed
P0IPM Reset
P5Compressor Current Protection
P6Communication Error between the Inverter Drive and the Main Controller
P7Radiator Temp Sensor Error
P8Radiator Overheat Protection
P9AC Contactor Protection
PcCurrent Sensor Error
PdSensor Connection Protection
PHOver Voltage Protection
PLLow Voltage Protection
PETemp Drift Protection
PFDrive Board Ambient Temp Sensor Error
PAAC Current Protection
PUCharging Circuit Error
PPAC Input Voltage Anomaly

Troubleshooting

Before calling for service, review this list. It may save you time and expense. This list includes common occurrences that are not the result of defective workman-ship or materials in this appliance.

Problem: The unit will not operate at all.

Cause:

  1. Blown Fuse or tripped circuit breaker
  2. Power Failure
  3. Remote Control batteries are low
  4. Signal from remote control is not being sent

Solution:

  1. Check the fuse or circuit breaker. Replace the blown fuse or reset the circuit breaker.
  2. Wait until the power is restored to restart the unit. If you experience brown out conditions, contact an electrician or your local utility.
  3. Replace the batteries. Be sure not to mix old and new batteries, as well as different brands/types
  4. Be sure that you are not using the remote control too far away from the indoor unit’s control panel.

Problem: The unit runs and then stops immediately

Cause: Air inlets and/or outlets are blocked

Solution: Remove any obstacles from the air inlets/outlets/Clean the air filter, louvers, and inlet grille.

Problem: Abnormal heating or cooling

Cause:

  1. Air inlets and/or outlets are blocked
  2. Improper temperature is set
  3. Check the fan speed
  4. Improper louver adjustment
  5. Be sure that there are no other sources of heat/steam in the area being cooled
  6. Conditioned air might be escaping

Solution:

  1. Remove any obstacles from the air inlets/outlets-Clean the air filter, louvers, and inlet grille.
  2. Ensure that the proper mode and temperature is set on the unit. Try to adjust the set point temperature on the thermostat to a better operating temperature
  3. Adjust the fan speed to see if that improves the conditions.
  4. Try to adjust the louver position to ensure it is open enough.
  5. Remove or turn off other appliances producing heat or steam.
  6. Ensure that any doors or windows in the area being heated/cooled are closed

Problem: Air from unit does not feel cold enough

Solution:

  1. Room temperature below 62 F(17 C ). Cooling may not occur until room temperature O O rises above 62 F(17 C).
  2. Temperature sensing behind air filter element touching cold coil. Keep it from the cold coil.
  3. Set to a Lower temperature.
  4. Compressor stopped when changing modes. Wait for 3 minutes after set to the COOL mode.

Problem: Noise when unit is cooling

Solution:

  1. Air movement sound. This is normal . If too loud, set to a slower FAN setting.
  2. Window vibration – poor installation. Refer to installation instructions or check with installer.
Comfort Aire Mini Split Ductless Air Conditioners Error Codes
Comfort Aire Mini Split Ductless Air Conditioners Error Codes

 

After power on, LED3 (Green color) and LED2 (Red color) will be flash if the unit has some
After power on, LED3 (Green color) and LED2 (Red color) will be flash if the unit has some
Table-4-Meaning-of-Each-Error
Table-4-Meaning-of-Each-Error
Table-4-Meaning-of-Each-Error2
Table-4-Meaning-of-Each-Error2

COMFORT-AIRE BG-81P Owner’s Manual PDF

Comments

Popular posts from this blog

Rittal Air Conditioner Error Codes

  System messages are shown on the display screen of the Comfort controller via the displays A1 to A20 and E0. Rittal Air Conditioner Error Codes Error Codes System message Possible cause A1 Enclosure door open Door open or door limit switch incorrectly positioned A2 Internal temperature of enclosure too high Cooling capacity inadequate/unit undersized. Error as a consequence of messages A03 to A17. A3 Filter monitoring Filter mat soiled A4 Ambient temperature too high/too low Ambient temperature outside of admissible operating range (+10°C to +60°C) A5 Icing hazard Operational display in case of icing hazard. A6 PSAH pressure-operated switch Ambient temperature too high A7 Evaporator coil Lack of coolant; sensor in front of or behind condenser defective. A8 Condensate warning Condensate discharge kinked or blocked A9 Condenser fan blocked or defective Blocked or defective A10 Evaporator fan blocked or defective Blocked or defective A11 Compressor Compressor overloaded A12 Condense...

Samsung DVM-S VRF Error Codes

  DVM Digital Variable Multi VRF Systems Error Codes Samsung DVM VRF Error Codes Error code related indoor unit: Error Codes Explanation E-101 Indoor unit communication error. Indoor unit can not receive any data from outdoor unit. E-102 Communication error between indoor unit and outdoor unit. Displayed in indoor unit. E-108 Error due to repeated address setting (When 2 or more devices has same address within the network) E-121 Error on indoor temperature sensor of indoor unit (Short or Open) E-122 Error on EVA IN sensor of indoor unit (Short or Open) E-123 Error on EVA OUT sensor of indoor unit (Short or Open) E-128 EVA IN temperature sensor of indoor unit is detached from EVA IN pipe E-129 EVA OUT temperature sensor of indoor unit is detached from EVA OUT pipe E-130 Heat exchanger in/out sensors of indoor unit are detached E-135 RPM feedback error of indoor unit's cleaning fan E-149 Error due to AHU master indoor unit sensor setting. E-151 Error due to opened EEV of indoor unit ...

Panasonic VRF AC Error Codes and Troubleshooting

  Indoor unit is detecting error signal from remote controller (and system controller). Panasonic Mini VRF AC Error Codes and Troubleshooting Error Codes Meaning E01 Error in receiving serial communication signal. E02 Error in transmitting serial communication signal. E03 Indoor unit is detecting error signal from remote controller. E04 Error in receiving serial communication signal. When turning on the power supply, the number of connected indoor units does not correspond to the number set. E06 Error of the outdoor unit in receiving serial communication signal from the indoor unit. E08 Indoor unit address setting is duplicated. E09 Remote controller address connector. E12 Starting auto address setting is prohibited. This alarm message shows that the auto address connector CN-A.ADD is shorted while other RC line is executing auto address operation. E15 Error in auto address setting. E16 Error in auto address setting. E20 No indoor unit is connected during auto address setting. E24 ...