Chunlan Air Conditioner Error Codes

 Microprocessor-based controller of this unit features troubleshooting and protection display  functions.

Chunlan Air Conditioner Error Codes
Chunlan Air Conditioner Error Codes
Error CodesProblem
E0High pressure protection
E1Antifreeze protection
E2ID ambient temp probe short circuit
E3ID pipe temp probe short circuit
E4OD pipe temp probe short circuit
E5Communication failure
E6Phase sequence protection
E7Overcurrent protection
E8Load relief protection
E9Low pressure protection

In case of repeated protections of air conditioner, cut off power supply and have failure corrected by specialty maintenance personnel, before restarting the machine.

 Chunlan Air Conditioner Error Codes / E1-E2-E3-E4
Chunlan Air Conditioner Error Codes / E0-E1-E2-E3-E4-E5-E6-E7-E8-E9

Common Troubleshooting

In case of AC failure, immediately cut off power supply. Check the following before requesting maintenance:

Failure: Machine not operating

Causes:

  1. Power off
  2. Power not meeting requirement
  3. Molten fuse or open CB

Correction measures:

  1. Use when power is resumed
  2. Check power supply before use
  3. Replace fuse or close circuit breaker

Failure: Machine operating at poor cooling/heating efficiency, or not cooling or heating

Causes:

  1. Clogged air strainer
  2. ID or OD unit air intake clogged
  3. Improper temp control setting
  4. Open door/window

Correction measures:

  1. Clean air strainer
  2. Remove obstacles
  3. Reset temperature control
  4. Close doors/windows

This air duct type air conditioner is our latest home (commercial) centralized air conditioning product.

This product features high efficiency, energy saving, mild and silent operation, computerized intelligent control and healthy fresh air etc.

In addition, wire and wireless controls are provided for easy operation.

The product can be widely used in large area, multi-room composite compartment/houses, villa, and medium and small restaurants, bars, leisure and recreation sites.

Chunlan Air Conditioner Ordinary wire controller
Chunlan Air Conditioner Ordinary wire controller

Note:

1. For relevant models and parameters provided in this manual, actual products and nameplate information shall govern;

2. This manual has been carefully checked. In case of printing error, our company shall not bear responsibility for the consequences.

3. Our company is in constant technology advancement and product series and sizes will be adjusted from time to time. Please note information of our new products.

Chunlan Air Conditioner Manual PDF


Comments

Popular posts from this blog

Rittal Air Conditioner Error Codes

  System messages are shown on the display screen of the Comfort controller via the displays A1 to A20 and E0. Rittal Air Conditioner Error Codes Error Codes System message Possible cause A1 Enclosure door open Door open or door limit switch incorrectly positioned A2 Internal temperature of enclosure too high Cooling capacity inadequate/unit undersized. Error as a consequence of messages A03 to A17. A3 Filter monitoring Filter mat soiled A4 Ambient temperature too high/too low Ambient temperature outside of admissible operating range (+10°C to +60°C) A5 Icing hazard Operational display in case of icing hazard. A6 PSAH pressure-operated switch Ambient temperature too high A7 Evaporator coil Lack of coolant; sensor in front of or behind condenser defective. A8 Condensate warning Condensate discharge kinked or blocked A9 Condenser fan blocked or defective Blocked or defective A10 Evaporator fan blocked or defective Blocked or defective A11 Compressor Compressor overloaded A12 Condense...

Samsung DVM-S VRF Error Codes

  DVM Digital Variable Multi VRF Systems Error Codes Samsung DVM VRF Error Codes Error code related indoor unit: Error Codes Explanation E-101 Indoor unit communication error. Indoor unit can not receive any data from outdoor unit. E-102 Communication error between indoor unit and outdoor unit. Displayed in indoor unit. E-108 Error due to repeated address setting (When 2 or more devices has same address within the network) E-121 Error on indoor temperature sensor of indoor unit (Short or Open) E-122 Error on EVA IN sensor of indoor unit (Short or Open) E-123 Error on EVA OUT sensor of indoor unit (Short or Open) E-128 EVA IN temperature sensor of indoor unit is detached from EVA IN pipe E-129 EVA OUT temperature sensor of indoor unit is detached from EVA OUT pipe E-130 Heat exchanger in/out sensors of indoor unit are detached E-135 RPM feedback error of indoor unit's cleaning fan E-149 Error due to AHU master indoor unit sensor setting. E-151 Error due to opened EEV of indoor unit ...

Panasonic VRF AC Error Codes and Troubleshooting

  Indoor unit is detecting error signal from remote controller (and system controller). Panasonic Mini VRF AC Error Codes and Troubleshooting Error Codes Meaning E01 Error in receiving serial communication signal. E02 Error in transmitting serial communication signal. E03 Indoor unit is detecting error signal from remote controller. E04 Error in receiving serial communication signal. When turning on the power supply, the number of connected indoor units does not correspond to the number set. E06 Error of the outdoor unit in receiving serial communication signal from the indoor unit. E08 Indoor unit address setting is duplicated. E09 Remote controller address connector. E12 Starting auto address setting is prohibited. This alarm message shows that the auto address connector CN-A.ADD is shorted while other RC line is executing auto address operation. E15 Error in auto address setting. E16 Error in auto address setting. E20 No indoor unit is connected during auto address setting. E24 ...