Bosch Air Conditioner Error Codes

 

Bosch Air Conditioner Error Codes
Bosch Air Conditioner Error Codes

If you see an error code not displayed in Table , contact the manufacturer as the error displayed is for development purpose only.

Error CodesSolutions
E0Indoor unit EEPROM parameter error
E1Indoor / outdoor units communication error
E2Zero-crossing signal detection error
E3Indoor fan speed has been out of control
E4Indoor room temperature sensor T1 open circuit or short circuit
E5Evaporator coil temperature sensor T2 open circuit or short circuit
ECRefrigerant leakage detection
F0Overload current protection
F1Outdoor ambient temperature sensor T4 open circuit or short circuit
F2Condenser coil temperature sensor T3 open circuit or short circuit
F3Compressor discharge temperature sensor T5 open circuit or short circuit
F4Outdoor unit EEPROM parameter error
F5Outdoor fan speed has been out of control
P0IPM malfunction or IGBT over-strong current protection
P1Over voltage or over low voltage protection
P2High temperature protection of IPM module or compressor top
P3Outdoor ambient temperature too low
P4Inverter compressor drive error
P5Indoor units mode confl ict (multi-zone ONLY)
21DC Peak (IPM Fault). IPM = Intelligent Power module. Restart 10x/hour, then blocked. Compressor broken or too much refrigerant in compressor.
22CT 2 (Max CT). Restart after problem has vanished. Inverter current > 14 A.
23DC Link Voltage is low or high. Restart after problem has vanished. Direct voltage 1~: <140 VDC or >480 (3kW: 420) VDC 3~: <320VDC or >780VDC.
26Problem in DC Compressor positioning. Restart 10x/hour, then blocked. Wrong orientation of compressor connections (UVW).
27PSC Fault. Restart 10x/hour, then blocked. High current IGBT (check reactor).
29High current at Compressor phases. Restart 10x/hour, then blocked.
32Temperature at discharge-pipe is too high. Restart after problem has vanished. Hot gas temperature TH5 >105 °C (check refrigerant load).
35Low Pressure error. Restart 3x/hour, then blocked. Low Pressure < 0 kPa ( – 49.5 °C).
41Problem in discharge-pipe temperature sensor. Direct shut-down. Sensor TH5 broken (200k ohm >25 °C).
43High-pressure sensor (Open/ Short). Direct shut-down. LP/HP sensor broken.
44Problem in ambient temperature sensor. Direct shut-down. Sensor TH7 broken (10k ohm >25 °C).
45Problem in condenser-middle-pipe temperature sensor. Direct shut-down. Sensor TH8 broken (5k ohm >25 °C).
46Problem in suction-pipe temperature sensor. Direct shut-down. Sensor TH4 broken (5k ohm>25 °C).
48Cond. Out-pipe Th Error (Open/ Short). Direct shut-down. Sensor TH6 broken (5k ohm>25 °C).
52Bad communication between Inverter-PCB and Main-PCB. Restart 3x/hour, then blocked. Wiring between Mainboard and Inverter board damaged (3~ phase only).
53Bad communication between CanPCB and Main-PCB. Direct shut-down. Wiring between Mainboard and CAN-PCB damaged.
54Phase sequence incorrect. Restart 10x/hour, then blocked. only 2 phases or incorrect rotation field (3~ phase only).
55CAN Communication error (CANPCB <=> Installerboard). Direct shut-down. Wiring between CAN-PCB and Indoor unit damaged.
60EEPROM Checksum mismatched. Direct shut-down. Change EEPROM.
61Temperature at condenser-pipe is too high. Restart after problem has vanished. Condensing temperature >65.3°C (4199 kPa) {Heating} Condensing temperature >64.2 °C(4101 kPa) {Cooling}.
62Temperature at heat sink is too high. Restart after problem has vanished. Heat sink temperature >85 °C.
65Problem in heatsink temperature sensor. Direct shut-down. Heat sink sensor / Inverter-PCB broke.
67ODU BLDC fan lock. Restart 10x/hour, then blocked. Fan blocked.
CFwhen anti-cold air feature is turned on
dFwhen defrosting
SCwhen unit is self-cleaning
FPwhen freeze protection is turned on
Bosch Remote Controller for Split Type Ductless Air Conditioner
Bosch Remote Controller for Split Type Ductless Air Conditioner

Bosch Air Conditioner Troubleshooting

The following problems are not a malfunction and in most situations will not require repairs.

1. Unit does not turn on when pressing ON/OFF button: The unit has a 3-minute protection feature that prevents the unit from overloading. The unit cannot be restarted within three minutes of being turned off.

2.The unit changes from COOL/HEAT mode to FAN mode: The unit may change its setting to prevent frost from forming on the unit. Once the temperature increases, the unit will start operating in the previously selected mode again. The set temperature has been reached, at which point the unit turns off the compressor. The unit will continue operating when the temperature fluctuates again.

3.The indoor unit emits white mist: In humid regions, a large temperature difference between the room’s air and the conditioned air can cause white mist.

4.Both the indoor and outdoor units emit white mist: When the unit restarts in HEAT mode after defrosting, white mist may be emitted due to moisture generated from the defrosting process.

5.The outdoor unit makes noises: The unit will make different sounds based on its current operating mode.

Cleaning Your Air Filter

A clogged air conditioner can reduce the cooling efficiency of your unit, and can also be bad for your health. Make sure to clean the filter once every two weeks.

Bosch AC Cleaning Your Air Filter
Bosch AC Cleaning Your Air Filter
  1. Lift the front panel of the indoor unit.
  2. First press the tab on the end of filter to loosen the buckle, lift it up, then pull it towards yourself.
  3. Now pull the filter out.
  4. If your filter has a small air freshening filter, unclip it from the larger filter. Clean this air freshening filter with a hand-held vacuum.
  5. Clean the large air filter with warm, soapy water. Ensure to use a mild detergent.
  6. Rinse the filter with fresh water, then shake off excess water.
  7. Dry it in a cool, dry place and refrain from exposing it to direct sunlight.
  8. When dry, re-clip the air freshening filter to the larger filter, then slide it back into the indoor unit.
  9. Close the front panel of the indoor unit.

Bosch Air Conditioner Wiring Diagrams

Bosch AC Indoor Wiring Diagram
Bosch AC Indoor Wiring Diagram
Bosch AC Outdoor Wiring Diagram
Bosch AC Outdoor Wiring Diagram

Bosch Climate 5000 AA Series Split Type Ductless Air Conditioner PDF

Bosch Remote Controller for Split Type Ductless Air

Comments

Popular posts from this blog

Rittal Air Conditioner Error Codes

  System messages are shown on the display screen of the Comfort controller via the displays A1 to A20 and E0. Rittal Air Conditioner Error Codes Error Codes System message Possible cause A1 Enclosure door open Door open or door limit switch incorrectly positioned A2 Internal temperature of enclosure too high Cooling capacity inadequate/unit undersized. Error as a consequence of messages A03 to A17. A3 Filter monitoring Filter mat soiled A4 Ambient temperature too high/too low Ambient temperature outside of admissible operating range (+10°C to +60°C) A5 Icing hazard Operational display in case of icing hazard. A6 PSAH pressure-operated switch Ambient temperature too high A7 Evaporator coil Lack of coolant; sensor in front of or behind condenser defective. A8 Condensate warning Condensate discharge kinked or blocked A9 Condenser fan blocked or defective Blocked or defective A10 Evaporator fan blocked or defective Blocked or defective A11 Compressor Compressor overloaded A12 Condense...

Samsung DVM-S VRF Error Codes

  DVM Digital Variable Multi VRF Systems Error Codes Samsung DVM VRF Error Codes Error code related indoor unit: Error Codes Explanation E-101 Indoor unit communication error. Indoor unit can not receive any data from outdoor unit. E-102 Communication error between indoor unit and outdoor unit. Displayed in indoor unit. E-108 Error due to repeated address setting (When 2 or more devices has same address within the network) E-121 Error on indoor temperature sensor of indoor unit (Short or Open) E-122 Error on EVA IN sensor of indoor unit (Short or Open) E-123 Error on EVA OUT sensor of indoor unit (Short or Open) E-128 EVA IN temperature sensor of indoor unit is detached from EVA IN pipe E-129 EVA OUT temperature sensor of indoor unit is detached from EVA OUT pipe E-130 Heat exchanger in/out sensors of indoor unit are detached E-135 RPM feedback error of indoor unit's cleaning fan E-149 Error due to AHU master indoor unit sensor setting. E-151 Error due to opened EEV of indoor unit ...

Panasonic VRF AC Error Codes and Troubleshooting

  Indoor unit is detecting error signal from remote controller (and system controller). Panasonic Mini VRF AC Error Codes and Troubleshooting Error Codes Meaning E01 Error in receiving serial communication signal. E02 Error in transmitting serial communication signal. E03 Indoor unit is detecting error signal from remote controller. E04 Error in receiving serial communication signal. When turning on the power supply, the number of connected indoor units does not correspond to the number set. E06 Error of the outdoor unit in receiving serial communication signal from the indoor unit. E08 Indoor unit address setting is duplicated. E09 Remote controller address connector. E12 Starting auto address setting is prohibited. This alarm message shows that the auto address connector CN-A.ADD is shorted while other RC line is executing auto address operation. E15 Error in auto address setting. E16 Error in auto address setting. E20 No indoor unit is connected during auto address setting. E24 ...