 The appliance has a self diagnosis system to identify a number of malfunctions. Error messages are displayed on the appliance display.

Black and Decker Portable AC Error Codes and Troubleshooting
Black and Decker Portable AC Error Codes and Troubleshooting
Error CodesWhat should I do?
LEIf you displayed LE, Low Temperature (frost prevention) The appliance is fitted with a frost protection device to avoid excessive formation of ice. The appliance start up again automatically when the defrosting process is completed.
PFIf you displayed PF, Probe Failure (sensor damaged) If this is displayed, contact your local authorised service centre.
FEIf you displayed FE, Full Tank (safety tank full) Empty the internal safety tank, following the instructions in the ''End of season operations'' paragraph.
Black and Decker Portable AC Remote Control
Black and Decker Portable AC Remote Control

Troubleshooting

Troubleshoot your problem by using the chart below. If the air conditioner still does not work properly, contact W Appliance Co. customer service center or the nearest authorized service center. Customers must never troubleshoot internal components.

Trouble: Unit does not start when pressing ON/OFF button

Possible Cause:

  1. FT appears in the display window
  2. Room temperature is lower than set temperature (cooling mode)

Possible Remedy:

  1. Drain the water in the bottom tray
  2. Reset the temperature
Black and Decker Portable AC Control Panel
Black and Decker Portable AC Control Panel

Trouble: Not cool enough

Possible Cause:

  1. The windows or doors in the room are not closed
  2. There are heat sources inside the room
  3. Exhaust air duct is not connected or blocked
  4. Temperature setting is too high
  5. Air filter is blocked by dust
  6. The unit will take approx 3 minutes of operation before cooling/heating occurs.

Possible Remedy:

  1. Make sure all the windows and doors are closed
  2. Remove the heat sources if possible
  3. Connect the duct and make sure it can function properly
  4. Decrease the set temperature
  5. Clean the air filter
  6. A mircoprocessor control delays the compressor from operating until 3 mins have passed.

Trouble: Noisy or vibration

Possible Cause: The surface is not level or not flat enough

Possible Remedy: Place the unit on a flat, level surface if possible

Trouble: Gurgling sound

Possible Cause: The sound comes from the flowing of the refrigerant inside the air-conditioner

Possible Remedy: It is normal

Trouble: Unit stops operating

Possible Cause: LT appears in display window

Possible Remedy: Unit is in defrost mode and will restart automatically once excess frost has been removed.

Black and Decker Portable AC Troubleshooting
Black and Decker Portable AC Troubleshooting

Water Drainage Method

This air conditioner is equipped with the very latest MIST technology which means the water tank nearly never fills, hence water drainage will generally only be required at the end of the season (see START-END OF SEASON OPERATIONS in page 19. However the MIST technology does not operate when the unit is in HEAT mode. Thus the tank may still require emptying in HEAT mode.

NOTE: As a safety measure to positively prevent water spillage the air conditioner is equipped with a fail safe device if the water tank fills. The unit will completely stop, the control panel displays ft (FULL TANK) as mentioned on SELF DIAGNOSIS in page 17. The compressor and fan will not restart until the tank has been drained.

Cleaning The Filters

To keep your air conditioner working efficiently, you should clean the filters every week of operation. The evaporator filter can be removed as shown in Fig. 12.

Black and Decker Portable AC - Cleaning The Filters
Black and Decker Portable AC – Cleaning The Filters

The condenser filter is two pieces.

  • STEP 1: Take out one filter as shown in Fig. 13.
  • STEP 2: Take out other filter as shown in Fig. 14 and Fig. 15.

Use a vacuum cleaner to remove dust accumulations from the filters. If it is very dirty, immerse in warm water and rinse a number of times. The water should be luke warm. After washing, leave the filters to dry then re-insert.

Black and Decker Portable AC Manual PDF

Comments

Popular posts from this blog

Rittal Air Conditioner Error Codes

  System messages are shown on the display screen of the Comfort controller via the displays A1 to A20 and E0. Rittal Air Conditioner Error Codes Error Codes System message Possible cause A1 Enclosure door open Door open or door limit switch incorrectly positioned A2 Internal temperature of enclosure too high Cooling capacity inadequate/unit undersized. Error as a consequence of messages A03 to A17. A3 Filter monitoring Filter mat soiled A4 Ambient temperature too high/too low Ambient temperature outside of admissible operating range (+10°C to +60°C) A5 Icing hazard Operational display in case of icing hazard. A6 PSAH pressure-operated switch Ambient temperature too high A7 Evaporator coil Lack of coolant; sensor in front of or behind condenser defective. A8 Condensate warning Condensate discharge kinked or blocked A9 Condenser fan blocked or defective Blocked or defective A10 Evaporator fan blocked or defective Blocked or defective A11 Compressor Compressor overloaded A12 Condense...

Samsung DVM-S VRF Error Codes

  DVM Digital Variable Multi VRF Systems Error Codes Samsung DVM VRF Error Codes Error code related indoor unit: Error Codes Explanation E-101 Indoor unit communication error. Indoor unit can not receive any data from outdoor unit. E-102 Communication error between indoor unit and outdoor unit. Displayed in indoor unit. E-108 Error due to repeated address setting (When 2 or more devices has same address within the network) E-121 Error on indoor temperature sensor of indoor unit (Short or Open) E-122 Error on EVA IN sensor of indoor unit (Short or Open) E-123 Error on EVA OUT sensor of indoor unit (Short or Open) E-128 EVA IN temperature sensor of indoor unit is detached from EVA IN pipe E-129 EVA OUT temperature sensor of indoor unit is detached from EVA OUT pipe E-130 Heat exchanger in/out sensors of indoor unit are detached E-135 RPM feedback error of indoor unit's cleaning fan E-149 Error due to AHU master indoor unit sensor setting. E-151 Error due to opened EEV of indoor unit ...

Panasonic VRF AC Error Codes and Troubleshooting

  Indoor unit is detecting error signal from remote controller (and system controller). Panasonic Mini VRF AC Error Codes and Troubleshooting Error Codes Meaning E01 Error in receiving serial communication signal. E02 Error in transmitting serial communication signal. E03 Indoor unit is detecting error signal from remote controller. E04 Error in receiving serial communication signal. When turning on the power supply, the number of connected indoor units does not correspond to the number set. E06 Error of the outdoor unit in receiving serial communication signal from the indoor unit. E08 Indoor unit address setting is duplicated. E09 Remote controller address connector. E12 Starting auto address setting is prohibited. This alarm message shows that the auto address connector CN-A.ADD is shorted while other RC line is executing auto address operation. E15 Error in auto address setting. E16 Error in auto address setting. E20 No indoor unit is connected during auto address setting. E24 ...