Ameristar AC Error Codes and Troubleshooting

 Single Zone Mini-Split Inverter System Error Codes:

Ameristar AC Error Codes and Troubleshooting-min
Ameristar AC Error Codes and Troubleshooting-min
Error CodesSolution
E5AC over current protection. Restart the unit. If the error does not clear, contact your dealer or qualified service technician.
E8High temperature protection. Restart the unit. If the error does not clear, contact your dealer or qualified service technician.
H4High temperature protection. Restart the unit. If the error does not clear, contact your dealer or qualified service technician.
H6Indoor fan motor error. Restart the unit. If the error does not clear, contact your dealer or qualified service technician.
C5Jumper cap malfunction protection. Contact your dealer or qualified service technician.
F1Indoor ambient sensor open or short circuit. Contact your dealer or qualified service technician.
F2Indoor tube sensor open or short circuit. Contact your dealer or qualified service technician.

If other error codes are present, contact your dealer or qualified service technician.

If any of the following occurs, shut off the unit and contact your dealer or qualified service technician:

  • Power cord overheats or becomes damaged
  • If you notice a burning smell
  • The unit trips the breaker panel or cycles off frequently without obtaining the set temperature
  • Abnormal sound during operation
  • If you notice water leakage
Ameristar AC Remote Control Meaning
Ameristar AC Remote Control Meaning
Ameristar AC Remote Control Screen Icons
Ameristar AC Remote Control Screen Icons

Troubleshooting

Condition: Unit doesn’t run

  1. When unit is started immediately after it is just turned off
  2. When power is turned on

Possible Reason:

  1. Overload protection switch delays unit start up for three minutes
  2. The unit is in standby for one minute

Condition: Mist comes from the unit. When cooling cycle starts

Possible Reason: Indoor high humidity air is cooled rapidly

Condition: Sound comes from the unit

  1. Slight cracking sound is heard when unit starts
  2. There is sound when cooling
  3. There is sound when unit starts or stops
  4. There is slight sound when unit is running or after running
  5. Cracking sound is heard when unit is operating and after operating

Possible Reason:

  1. This sound occurs when the electronic expansion valve initializes.
  2. The sound of gas refrigerant flowing in unit
  3. This sound occurs when gas refrigerant starts or stops flowing
  4. The sound of the drainage system operating
  5. This sound occurs when the unit panels expand or contract due to temperature change

Condition: The unit blows out dust. When the unit has been off for a period of time.

Possible Reason: Dust in indoor unit is blown out

Condition: The unit emits odor. When the unit is operating

Possible Reason: The room odor absorbed by the unit is blown out again

Condition: Indoor unit still runs after switch off. After every indoor unit receives the “stop” signal, fan will keep running

Possible Reason: Indoor fan motor will keep running 20-70 seconds to use excess cooling and heating and prepare for the next operation

Condition: Mode conflict. COOL or HEAT mode can not be operated.

Possible Reason: When the indoor operating mode conflicts with that of the outdoor unit, the indoor fault indicator will flash and conflict will be shown on the wired controller after 5 minutes. Indoor unit stops running and the outdoor unit changes its mode of operation to match the indoor unit, then the unit will go back to normal. COOL mode doesn’t conflict with DRY mode. FAN mode doesn’t conflict with any mode.

NOTE: If the problem persists after checking the above items and taking appropriate measures, please stop operation of the unit immediately and contact your local service agency or dealer. Diagnostics and repairs should be completed by a professional service technician.

Auxiliary Operation

Auxiliary Operation
Auxiliary Operation

If the remote controller is lost or damaged, please use the auxiliary button to turn on or turn off the air conditioner. Open the front panel of the unit and press the aux. button to turn on or turn off the unit. When the unit is operated by the auxilliary button it will run only in auto mode.

Note: Auto mode operation – 77°F is the set temperature for cooling operation and 68°F is the set temperature for heating operation. There is no adjustment available for auto mode operation.

Indoor Unit Maintenance

Indoor Unit Maintenance
Indoor Unit Maintenance
  1. Clean the outer surface of the unit with a dry or damp cloth.
  2. If there is residue, the unit may be cleaned with a mild detergent solution. Do not use chemical solvents or flammable liquids to clean the surface of the unit. Wipe dry after cleaning with a soft dry cloth.
  3. Clean the filter a minimum of every three months. Clean more often if it is in an area that is dusty or smoky.
  4. Open the front outer panel of the indoor unit.
  5. Remove the filter by grasping the edges and pulling downward.
  6. Clean the filter using a vacuum or rinse under cool, clear water.
  7. If the filter is very dirty, use warm water (below 115°F/ 45°C). A mild detergent should only be used if the residue cannot be removed with warm water. Rinse the filter thoroughly before allowing to air dry. If the filter cannot be adequately cleaned, contact your dealer for a replacement filter.
  8. Let the filter air dry to avoid warping. Do not dry the filter in direct sunlight.
  9. Reinstall the filter into the clips and close the front panel.

Ameristar AC Manual PDF

Comments

Popular posts from this blog

Rittal Air Conditioner Error Codes

  System messages are shown on the display screen of the Comfort controller via the displays A1 to A20 and E0. Rittal Air Conditioner Error Codes Error Codes System message Possible cause A1 Enclosure door open Door open or door limit switch incorrectly positioned A2 Internal temperature of enclosure too high Cooling capacity inadequate/unit undersized. Error as a consequence of messages A03 to A17. A3 Filter monitoring Filter mat soiled A4 Ambient temperature too high/too low Ambient temperature outside of admissible operating range (+10°C to +60°C) A5 Icing hazard Operational display in case of icing hazard. A6 PSAH pressure-operated switch Ambient temperature too high A7 Evaporator coil Lack of coolant; sensor in front of or behind condenser defective. A8 Condensate warning Condensate discharge kinked or blocked A9 Condenser fan blocked or defective Blocked or defective A10 Evaporator fan blocked or defective Blocked or defective A11 Compressor Compressor overloaded A12 Condense...

Samsung DVM-S VRF Error Codes

  DVM Digital Variable Multi VRF Systems Error Codes Samsung DVM VRF Error Codes Error code related indoor unit: Error Codes Explanation E-101 Indoor unit communication error. Indoor unit can not receive any data from outdoor unit. E-102 Communication error between indoor unit and outdoor unit. Displayed in indoor unit. E-108 Error due to repeated address setting (When 2 or more devices has same address within the network) E-121 Error on indoor temperature sensor of indoor unit (Short or Open) E-122 Error on EVA IN sensor of indoor unit (Short or Open) E-123 Error on EVA OUT sensor of indoor unit (Short or Open) E-128 EVA IN temperature sensor of indoor unit is detached from EVA IN pipe E-129 EVA OUT temperature sensor of indoor unit is detached from EVA OUT pipe E-130 Heat exchanger in/out sensors of indoor unit are detached E-135 RPM feedback error of indoor unit's cleaning fan E-149 Error due to AHU master indoor unit sensor setting. E-151 Error due to opened EEV of indoor unit ...

Panasonic VRF AC Error Codes and Troubleshooting

  Indoor unit is detecting error signal from remote controller (and system controller). Panasonic Mini VRF AC Error Codes and Troubleshooting Error Codes Meaning E01 Error in receiving serial communication signal. E02 Error in transmitting serial communication signal. E03 Indoor unit is detecting error signal from remote controller. E04 Error in receiving serial communication signal. When turning on the power supply, the number of connected indoor units does not correspond to the number set. E06 Error of the outdoor unit in receiving serial communication signal from the indoor unit. E08 Indoor unit address setting is duplicated. E09 Remote controller address connector. E12 Starting auto address setting is prohibited. This alarm message shows that the auto address connector CN-A.ADD is shorted while other RC line is executing auto address operation. E15 Error in auto address setting. E16 Error in auto address setting. E20 No indoor unit is connected during auto address setting. E24 ...