AEG Portable Air Conditioner Error Codes

 If the display reads “AS”, “CS” and “ES”, the temperature sensor has failed. Contact your Authorized AEG Service Center.

AEG Portable Air Conditioner Error Codes
AEG Portable Air Conditioner Error Codes
Error CodesSolution
ASTemperature sensor has failed.
CSTemperature sensor has failed.
ESTemperature sensor has failed.
L3Condenser DC fan motor has failed.
P1If the display reads “P1”, bottom tray is full. Carefully move the unit to a drain location, remove the bottom drain plug and let the water drain away. Restart the machine until the “P1” symbol disappears.
E4If the display reads “E4”, the communication between display PCB and main control PCB is faulty.

Troubleshooting

Before calling for service, review this list. It may save you time and expense. This list includes common occurrences that are not the result of defective workmanship or materials in this appliance.

Air conditioner will not operate.

  • Wall plug disconnected. Push plug firmly into wall outlet.
  • House fuse blown or circuit breaker tripped. Replace fuse with time delay type or reset circuit breaker.
  • Control is OFF. Turn Control ON and set to desired setting.
  • Fault code P1 appears in the display window. Drain water as described in 7.3 Drainage Section.
  • Room Temperature lower than the set temperature (Cool Mode) or Room Temperature higher than the set temperature (Heat Mode). Reset the temperature.

Air from unit does not feel cold enough.

  • Room temperature below 16°C. Cooling may not occur until room temperature rises above 16°C.
  • Reset to a lower temperature.
  • Compressor shut-off by changing modes. Wait approximately 4 minutes and listen for compressor to restart when set in the COOL mode.

Air conditioner cooling, but room is too warm – NO ice forming on cooling coil behind decorative front.

  • Outdoor temperature below 16°C. To defrost the coil, set Fan mode.
  • Air filter may be dirty. Clean filter. Care and Cleaning section. To defrost, set to Fan mode.
  • Temperature is set too low for nighttime cooling. To defrost the coil, set to Fan mode. Then, set temperature to a higher setting.
  • Exhaust duct not connected or blocked.

Air conditioner cooling, but room is too warm – ice forming on cooling coil behind decorative front.

  • Dirty air filter – air restricted. Clean air filter.  Care and Cleaning section.
  • Temperature is set too high. Set temperature to a lower setting.
  • Air directional louvers positioned improperly. Position louvers for better air distribution.
  • Front of unit is blocked by drapes, blinds, furniture, etc. – restricts air distribution. Clear blockage in front of unit.
  • Doors, windows, registers, etc. open – cool air escapes. Close doors, windows, registers, etc.

Air conditioner turns on and off rapidly.

  • Dirty air filter – air restricted. Clean air filter.
  • Outside temperature extremely hot. Set FAN speed to a faster setting to bring air through cooling coils more frequently

Room too cold.

  • Set temperature too low. Increase set temperature.

Care & Cleaning

Clean your air conditioner occasionally to keep it looking new. Be sure to unplug the unit before cleaning to prevent shock or fire hazards.

Cleaning the unit

The cabinet and front may be dusted with an oil-free cloth or washed with a cloth dampened in a solution of warm water and mild liquid dishwashing detergent. Never use harsh cleaners, wax or polish on the cabinet front. Be sure to wring excess water from the cloth before wiping around the controls. Excess water in or around the controls may cause damage to the air conditioner.

Cleaning the filters

AEG Portable Air Conditioner Cleaning the filters
AEG Portable Air Conditioner Cleaning the filters

To keep your air conditioner working efficiently, you should clean the filters every two weeks of operation.

  1. Removed the air filter as shown the below figure. Take out the upper air filter and the lower air filter.
  2. Wash the filter using liquid dishwashing detergent and warm water under 40°C. Rinse filter thoroughly. Gently shake excess water from the filter. Be sure filter is thoroughly dry before replacing. Or, instead of washing you may vacuum the filter clean.
  3. Replace the filter after the filter is dry.

Remote Control

AEG Portable Air Conditioner Remote Control
AEG Portable Air Conditioner Remote Control

Control Panel

AEG Portable Air Conditioner Control Panel
AEG Portable Air Conditioner Control Panel

Parts

AEG Portable Air Conditioner Parts
AEG Portable Air Conditioner Parts

AEG Portable Air Conditioner Manual PDF

Comments

Popular posts from this blog

Rittal Air Conditioner Error Codes

  System messages are shown on the display screen of the Comfort controller via the displays A1 to A20 and E0. Rittal Air Conditioner Error Codes Error Codes System message Possible cause A1 Enclosure door open Door open or door limit switch incorrectly positioned A2 Internal temperature of enclosure too high Cooling capacity inadequate/unit undersized. Error as a consequence of messages A03 to A17. A3 Filter monitoring Filter mat soiled A4 Ambient temperature too high/too low Ambient temperature outside of admissible operating range (+10°C to +60°C) A5 Icing hazard Operational display in case of icing hazard. A6 PSAH pressure-operated switch Ambient temperature too high A7 Evaporator coil Lack of coolant; sensor in front of or behind condenser defective. A8 Condensate warning Condensate discharge kinked or blocked A9 Condenser fan blocked or defective Blocked or defective A10 Evaporator fan blocked or defective Blocked or defective A11 Compressor Compressor overloaded A12 Condense...

Samsung DVM-S VRF Error Codes

  DVM Digital Variable Multi VRF Systems Error Codes Samsung DVM VRF Error Codes Error code related indoor unit: Error Codes Explanation E-101 Indoor unit communication error. Indoor unit can not receive any data from outdoor unit. E-102 Communication error between indoor unit and outdoor unit. Displayed in indoor unit. E-108 Error due to repeated address setting (When 2 or more devices has same address within the network) E-121 Error on indoor temperature sensor of indoor unit (Short or Open) E-122 Error on EVA IN sensor of indoor unit (Short or Open) E-123 Error on EVA OUT sensor of indoor unit (Short or Open) E-128 EVA IN temperature sensor of indoor unit is detached from EVA IN pipe E-129 EVA OUT temperature sensor of indoor unit is detached from EVA OUT pipe E-130 Heat exchanger in/out sensors of indoor unit are detached E-135 RPM feedback error of indoor unit's cleaning fan E-149 Error due to AHU master indoor unit sensor setting. E-151 Error due to opened EEV of indoor unit ...

Panasonic VRF AC Error Codes and Troubleshooting

  Indoor unit is detecting error signal from remote controller (and system controller). Panasonic Mini VRF AC Error Codes and Troubleshooting Error Codes Meaning E01 Error in receiving serial communication signal. E02 Error in transmitting serial communication signal. E03 Indoor unit is detecting error signal from remote controller. E04 Error in receiving serial communication signal. When turning on the power supply, the number of connected indoor units does not correspond to the number set. E06 Error of the outdoor unit in receiving serial communication signal from the indoor unit. E08 Indoor unit address setting is duplicated. E09 Remote controller address connector. E12 Starting auto address setting is prohibited. This alarm message shows that the auto address connector CN-A.ADD is shorted while other RC line is executing auto address operation. E15 Error in auto address setting. E16 Error in auto address setting. E20 No indoor unit is connected during auto address setting. E24 ...